{"title":"C.SCOPE","description":"\u003cp\u003e\u003cspan\u003eThe C.Scope Cable Avoidance Tool is a handheld device used to detect and locate buried or hidden cables and pipes underground. It emits a low-frequency magnetic field that interacts with the wires or pipes, causing them to emit a signal that the tool can detect and display on its screen. This allows operators to quickly and accurately locate cables and pipes without having to dig up the entire area, reducing the risk of damage or injury. The tool is commonly used in industries such as construction, excavation, and utility maintenance to prevent accidents and ensure safe digging practices.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"c-scope-dxl4-cable-avoidance-tool-dxl4-d","title":"C.SCOPE - DXL4 CABLE AVOIDANCE TOOL - DXL4-D","description":"\u003cp data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cspan\u003eThe C.Scope DXL4 is a dual-frequency (33+131kHz) Cable Avoidance Tool with Depth Measurement.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIn-built Data Logging as standard. Bluetooth™ connectivity and GPS tracking options available.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDesigned for use with an SGA4 or SGV4 Signal Generator.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp\u003eThe DXL4 Cable Avoidance Tools from C.Scope represent a significant advance in cable detecting performance.\u003c\/p\u003e\n\u003cp\u003eTwo versions of the DXL4 are available; the DXL4-D which has full data logging capability, and the DXL4-DBG which has full data logging capability, Bluetooth™ connectivity and GPS.\u003c\/p\u003e\n\u003cp\u003eInnovative new features have been introduced and the popular existing modes of detection have been enhanced to allow the DXL4 Cable Avoidance Tool to successfully detect even the hardest to find pipes and cables. Particular attention has been paid to effect better working practices and to minimise the potential for human error to impact on operating performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIMPROVED PERFORMANCE ACROSS ALL FOUR DETECTION MODES\u003cbr\u003e\u003c\/strong\u003eThe DXL4 Cable Avoidance Tool has improved performance across all modes of detection; Power, Radio, Generator and AllScan, whilst remaining easy to operate ensuring there is only a minimal need for training or retraining.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDEPTH MEASUREMENT\u003cbr\u003e\u003c\/strong\u003eThe DXL4 when used alongside an SGA4 or SGV4 Signal Generator will measure and indicate the depth of buried pipes, cables and sondes at the push of a button.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSIMULTANEOUS DUAL-FREQUENCY\u003cbr\u003e\u003c\/strong\u003eThe simultaneous dual-frequency 33kHz and 131kHz signal output of the Signal Generators is ideal for maximising the number of buried services that can be energised and then detected, providing a significant improvement in the detection of the smaller diameter or poorly earthed cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOVERLOAD PROTECTION\u003cbr\u003e\u003c\/strong\u003eOptimised Locator Sensitivity and Noise Rejection means that the DXL4 can deal with the highest levels of background interference found, allowing even the weakest of signals to be detected successfully.\u003c\/p\u003e\n\u003cp\u003eINTELLIGENT NEW FEATURES:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eALARM ZONE\u003cbr\u003e\u003c\/strong\u003eAlarmZone™ alerts operators to the presence of particularly shallow pipes or cables with the exact trigger depth adjustable by the user to best suit local requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDYNAMIC SWING SENSOR\u003cbr\u003e\u003c\/strong\u003eThe Dynamic SwingSensor which gently alerts the operator if the locator is being swung excessively, potentially compromising the accuracy of any locates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePEAKHOLD\u003cbr\u003e\u003c\/strong\u003ePeakHold allows operators to quickly and confidently pinpoint the exact position of buried services\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOGGING\u003cbr\u003e\u003c\/strong\u003eThe DXL4-D and DXL4-DBG Cable Avoidance Tools have full data logging capability. A years worth of data can be stored, in normal usage, on both the Cable Avoidance Tool and the SGV4 Signal Generator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOG TRANSFER via USB\u003cbr\u003e\u003c\/strong\u003eThis can be conveniently transferred at any time to supervisors for analysis via a USB cable to a PC (or wirelessly via Bluetooth™ from the DBG model only to a PC, tablet or smartphone).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA ANALYSIS\u003cbr\u003eC.SCOPE PC ‘TOOLKIT’ and ‘RELAY’ Smartphone App\u003cbr\u003e\u003c\/strong\u003eThe free-to-download C.Scope PC Toolkit and C.Scope Relay smartphone App analyses the stored data-logs into charts and graphs that illustrate all aspects of the use allowing training requirements to be quickly identified.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eThe DXL4-DBG with in-built GPS allows a record to be kept of exactly where the Locators have been used that can then be viewed in partnership with Google Earth™ or Google Maps™.\u003c\/p\u003e\n\u003cp\u003eTwelve months of GPS data is stored, in normal usage. This can be conveniently transferred at any time via a USB cable to a PC or wirelessly via Bluetooth™ to a PC, tablet or smartphone to supervisors for analysis. The free-to-download C.Scope PC Toolkit and Relay smartphone App analyses the stored data.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the Locators can be paired to third party GPS Survey equipment, via the Locators in-built Bluetooth™ facilitating ‘one pass’ underground utility surveys to be undertaken.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCALIBRATION\u003cbr\u003e\u003c\/strong\u003eThe DXL4 Cable Avoidance Tools do not require periodic recalibration. A fully Automatic Daily Self Test (ADST) tests and confirms that they are functioning at their optimum level each day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUTOMATIC DAILY SELF TEST (ADST)\u003cbr\u003e\u003c\/strong\u003eThe DXL4 Cable Avoidance Tools perform an Automatic Daily Self Test (ADST). The ADST checks the functionality of the locator including the receiving aerials each day when it is first switched on. The SGV4 Signal Generator also performs a comprehensive Automatic Daily Self Test (ADST).\u003c\/p\u003e\n\u003cp\u003eAt the start of each day of use, a positive Automatic Daily Self Test result gives confirmation to the operator that the kit is working at the optimum level.\u003c\/p\u003e\n\u003cp\u003eThe result of this test is recorded and stored on memory within the products in-built data files and can be downloaded onto a PC at any time within the following 12 months*.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT VALIDATION CERTIFICATION\u003cbr\u003e\u003c\/strong\u003eThese test results can be used to produce a Product Validation Certificate using the C.Scope PC Toolkit. In addition, any results of the Self Test that have been carried out in the last twelve months* are available. The PC Toolkit can also be used to view and print a copy of the original factory Calibration Certificate.\u003c\/p\u003e\n\u003cp\u003eC.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal requirements.\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIGH RESOLUTION BACKLIT DIGITAL DISPLAY\u003cbr\u003e\u003c\/strong\u003eThe DXL4 has a large, clear and easy to read backlit LCD mounted behind a protective polycarbonate lens. The display indicates detection mode, signal peak level, depth, signal strength and battery condition. It also displays the Automatic Daily Self Test results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDETACHABLE SPEAKER\u003cbr\u003e\u003c\/strong\u003eThe speaker can be easily detached for use in noisy work environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eROBUST AND DURABLE CONSTRUCTION\u003cbr\u003e\u003c\/strong\u003eThe DXL4s twin wall construction is robust and durable. It also provides IP65 standard protection against dust and water ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSERVICE\u003cbr\u003e\u003c\/strong\u003eA complete covers off service \u0026amp; maintenance package is available for those customers who require it from C.Scope Authorised Service Centres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe DXL4 comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOverview\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003ePower Mode\u003c\/li\u003e\n\u003cli\u003eRadio Mode\u003c\/li\u003e\n\u003cli\u003eGenerator Mode:\u003cbr\u003e\u003cem\u003eSimultaneous 33+131kHz\u003cbr\u003e33kHz signal detection for all purpose tracing and utility avoidance\u003cbr\u003e+ 131kHz for optimum detection of short length, small diameter or unearthed cables.\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eAll \u003c\/em\u003eScan Mode\u003c\/li\u003e\n\u003cli\u003eAccurate Depth Indication\u003c\/li\u003e\n\u003cli\u003eOverload Protection\u003c\/li\u003e\n\u003cli\u003eAlarm Zone\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003ePeak Hold\u003c\/li\u003e\n\u003cli\u003eDynamic Swing Sensor\u003c\/li\u003e\n\u003cli\u003eAutomatic Daily Self Test\u003c\/li\u003e\n\u003cli\u003eData Logging of all Locator activity\u003c\/li\u003e\n\u003cli\u003eData Transfer by USB. (Bluetooth\u003csup\u003eTM\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eoption)\u003c\/li\u003e\n\u003cli\u003eIn-Built GPS position logging (option)\u003c\/li\u003e\n\u003cli\u003eConnectivity to Survey level GPS products (options)\u003c\/li\u003e\n\u003cli\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eNo periodic Calibration required\u003c\/li\u003e\n\u003cli\u003eProduct Validation Certificate available\u003c\/li\u003e\n\u003cli\u003eNetwork Rail Approved\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSpec\u003c\/h3\u003e\n\u003cp\u003eThe DXL4 depth measuring Cable Avoidance Tool is available in two model types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDXL4-D Cable Avoidance Tool\u003cbr\u003eThe C.Scope DXL4-D is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool with in-built Data Logging.\u003c\/li\u003e\n\u003cli\u003eDXL4-DBG Cable Avoidance Tool\u003cbr\u003eThe C.Scope DXL4-DBG is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool with in-built Data Logging, Bluetooth™ connectivity and GPS tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth these products are designed for use with an SGA4 or an SGV4 Signal Generator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003cbr\u003eDXL4 Cable Avoidance Tool\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Nos.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDXL4-D\u003c\/li\u003e\n\u003cli\u003eDXL4-DBG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off Switch: Spring loaded trigger switch under handle\u003c\/li\u003e\n\u003cli\u003eFunction Select Switch (FOUR position): P. Power Mode; R. Radio Mode; G. Generator Mode; A. AllScan Mode\u003c\/li\u003e\n\u003cli\u003eSensitivity Control\u003c\/li\u003e\n\u003cli\u003eDepth Button. Push button for live display of depth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indication\u003cbr\u003e\u003c\/strong\u003eRemovable and user replaceable loudspeaker module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Indication\u003cbr\u003e\u003c\/strong\u003eMulti-segment Liquid Crystal Display indicating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSignal Strength\u003c\/li\u003e\n\u003cli\u003eMode selected\u003c\/li\u003e\n\u003cli\u003eAlarmZone™\u003c\/li\u003e\n\u003cli\u003eBattery Condition\u003c\/li\u003e\n\u003cli\u003eSelf Test Indicator\u003c\/li\u003e\n\u003cli\u003eGPS signal detected (DXL4-DBG only)\u003c\/li\u003e\n\u003cli\u003eBluetooth™ activated (DXL4-DBG only)\u003c\/li\u003e\n\u003cli\u003eDepth Measurement (in Generator Mode)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Logging\u003cbr\u003e\u003c\/strong\u003eInternal capacity for storing over 12 months of data (in normal use) logged once per second. Data logged includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTime\/Date\u003c\/li\u003e\n\u003cli\u003eMode\u003c\/li\u003e\n\u003cli\u003eSensitivity Level\u003c\/li\u003e\n\u003cli\u003eReceived Signal Level\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003cli\u003eDepth\u003c\/li\u003e\n\u003cli\u003eSelf Test Result\u003c\/li\u003e\n\u003cli\u003eSwing Indicator\u003c\/li\u003e\n\u003cli\u003eGPS position (DXL4-DBG only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth™\u003cbr\u003e\u003c\/strong\u003eBluetooth v2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eGPS\/QZSS\/GLONASS\/SBAS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Connector\u003cbr\u003e\u003c\/strong\u003eStandard USB Mini B connector in battery compartment. USB 2.0 Compatible\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelf Test\u003cbr\u003e\u003c\/strong\u003eAutomatic Daily Self Test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwing Indicator\u003cbr\u003e\u003c\/strong\u003eAudio beep to indicate incorrect use of the Locator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGenerator Mode Frequencies\u003cbr\u003e\u003c\/strong\u003eSimultaneous 131,072Hz and 32,768Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eCase moulded from high impact plastic. Designed to withstand 1m (3’3”) drop onto a hard surface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries)\u003cbr\u003e\u003c\/strong\u003e2.65kg (5 lb 13 oz)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e720mm x 280mm x 65mm (28.3” x 11” x 2.5”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLocate Accuracy: better than 10% of depth\u003c\/li\u003e\n\u003cli\u003eDepth Accuracy: ±5% @ 1m (3’3”)\u003c\/li\u003e\n\u003cli\u003eLine Depth Measurement Range: 0.1m to 9.99m (4” to 32’)\u003c\/li\u003e\n\u003cli\u003eLine Depth Resolution: 0.01m (0.4”)\u003c\/li\u003e\n\u003cli\u003eSonde Depth Measurement Range: 0.1m to 9.99m (4” to 32’) depending on Sonde type\u003c\/li\u003e\n\u003cli\u003eSonde Depth Resolution: 0.01m (0.4”)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 8 x ‘AA’ (LR6) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003e40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003cbr\u003e\u003c\/strong\u003e65\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNotes\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Locators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/30\/EU (EMC). Compliance has been demonstrated by testing representative samples to the relevant harmonised standards. All C.Scope Locators comply with the essential requirements and other provisions of Council Directive 2011\/65\/EU (RoHS).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDXL4-D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDXL4-DBG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator \/ Transmitter Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33+131kHz\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 131kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 8kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 512Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 640Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccurate Depth Indication\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Current Measurement\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarmZone™\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Hold\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Swing Sensor\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Daily Self Test\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Validation Certificate\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging Rate – once per second\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2GB Memory\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via USB\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via Bluetooth™\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Survey Level GPS via Bluetooth™\u003c\/td\u003e\n\u003ctd\u003e –\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Built GPS position logging\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo Periodic Calibration*\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 8 x AA (LR6) Alkaline or NiMH Rechargeable\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003cbr\u003e@ 1m depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Depth\u003cbr\u003e(max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e50-400Hz\u003c\/td\u003e\n\u003ctd\u003e5mA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio\u003c\/td\u003e\n\u003ctd\u003e10kHz-30kHz\u003c\/td\u003e\n\u003ctd\u003e25µA\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003e33+131kHz\u003c\/td\u003e\n\u003ctd\u003e5µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan\u003c\/td\u003e\n\u003ctd\u003e50Hz-33kHz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSonde\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRodding Oscillator\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Line\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Tip \/ Sonde\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cstrong\u003eDepth Measurement Range\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine\u003c\/td\u003e\n\u003ctd\u003e0.2m – 3.0m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSonde\u003c\/td\u003e\n\u003ctd\u003e0.25m – 9.9m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 5% of depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Cold Start\u003c\/td\u003e\n\u003ctd\u003e30s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Hot Start\u003c\/td\u003e\n\u003ctd\u003e1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. of Channels\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003eGPS, SBAS, QZSS, Galileo, GLONASS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cstrong\u003eBluetooth™\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion\u003c\/td\u003e\n\u003ctd\u003ev2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003ePC, Android and Apple iOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Rate\u003c\/td\u003e\n\u003ctd\u003e350kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNo Periodic Calibration\u003c\/strong\u003e. The DXL4 Cable Avoidance Tools do not require periodic recalibration. A Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. The DXL4 Cable Avoidance Tools use 8 x AA LR6 Alkaline or NiMH Rechargeable batteries sealed in a secure, fitted battery compartment. The battery pack will typically provide approximately 40 hours of service depending on use. The battery compartment also houses a spare battery holder\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDownloads\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL4_4pp-1.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-selected=\"1\"\u003e\u003c\/span\u003e\u003c\/em\u003e D\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eCXL4 Cable Avoidance Tool Brochure\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/10\/18_3-CATXL4-MANUAL_1018v2.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003eDCXL4 Cable Avoidance Tool Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":40444125446309,"sku":"125-3-1","price":1378.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/DXL4-3Q-DLBGPS-Power-1.jpg?v=1741790456"},{"product_id":"mxl4-precision-locator-mxl4-d","title":"C-SCOPE - MXL4 PRECISION LOCATOR - MXL4-D","description":"\u003cp data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cspan\u003eThe MXL4 is a high performance multi-frequency Precision Pipe \u0026amp; Cable Locator.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIn-built Data Logging as standard. Bluetooth™ connectivity and GPS tracking options available.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDesigned for use with an MXT4 Multi Frequency Transmitter.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp\u003eThe MXL4 Precision Locator represents a significant advance in cable detecting and tracing capabilities.\u003c\/p\u003e\n\u003cp\u003eTwo versions of the MXL4 are available; the MXL4-D which has full data logging capability, and the MXL4-DBG which has full data logging capability, Bluetooth™ connectivity and GPS.\u003c\/p\u003e\n\u003cp\u003eInnovative new features have been introduced enabling the MXL4 Locator and MXT4 Transmitter to provide high-end precision performance and a far more flexible approach to pipe and cable location.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIMPROVED PERFORMANCE\u003c\/strong\u003e\u003cbr\u003eThe MXL4 is able to quickly and accurately detect, pinpoint, trace and identify the widest range of pipes and cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOVERLOAD PROTECTION\u003cbr\u003e\u003c\/strong\u003eOptimised Locator Sensitivity and Noise Rejection means that the MXL4 can deal with the highest levels of background interference found, allowing even the weakest of signals to be detected successfully.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMULTI-FREQUENCY\u003cbr\u003e\u003c\/strong\u003eThe MXT4 Transmitter now has a greater range of transmitting frequencies allowing improved long distance tracing and utility identification, even on the most congested of sites. A range of frequencies from 512\/640Hz up to 131kHz and including the simultaneous dual-frequency 33kHz and 131kHz signal output is ideal for maximising the number of buried services that can be energised and then detected. The MXL4 can apply these frequency signals without direct connection to buried services, using either a Signal Clamp or the simple induction method from ground level, providing a significant improvement in the detection of the smaller diameter or poorly earthed cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDEPTH MEASUREMENT\u003cbr\u003e\u003c\/strong\u003eThe MXL4 when used alongside an MXT4 Transmitter will measure and indicate the depth of buried pipes, cables and sondes at the push of a button.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSIGNAL CURRENT MEASUREMENT\u003cbr\u003e\u003c\/strong\u003eThe MXL4 can monitor the true strength of the MXT4 Transmitter signal applied to a buried service irrespective of its depth. This is ideal for identifying the layout of a pipe or cable network.\u003c\/p\u003e\n\u003cp\u003eINTELLIGENT NEW FEATURES:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eALARM ZONE\u003cbr\u003e\u003c\/strong\u003eAlarmZone™ alerts operators to the presence of particularly shallow pipes or cables with the exact trigger depth adjustable by the user to best suit local requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDYNAMIC SWING SENSOR\u003cbr\u003e\u003c\/strong\u003eThe Dynamic SwingSensor which gently alerts the operator if the locator is being swung excessively, potentially compromising the accuracy of any locates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePEAKHOLD\u003cbr\u003e\u003c\/strong\u003ePeakHold allows operators to quickly and confidently pinpoint the exact position of buried services\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOGGING\u003cbr\u003e\u003c\/strong\u003eThe MXL4-D and MXL4-DBG Locators have full data logging capability. A years worth of data can be stored, in normal usage, on both the Locator and the MXT4 Transmitter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOG TRANSFER via USB\u003cbr\u003e\u003c\/strong\u003eThis can be conveniently transferred at any time to supervisors for analysis via a USB cable to a PC (or wirelessly via Bluetooth™ from the DBG model only to a PC, tablet or smartphone).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA ANALYSIS\u003cbr\u003eC.SCOPE PC ‘TOOLKIT’ and ‘RELAY’ Smartphone App\u003cbr\u003e\u003c\/strong\u003eThe free-to-download C.Scope PC Toolkit and C.Scope Relay smartphone App analyses the stored data-logs into charts and graphs that illustrate all aspects of the use allowing training requirements to be quickly identified.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eThe MXL4-DBG with in-built GPS allows a record to be kept of exactly where the Locators have been used that can then be viewed in partnership with Google Earth™ or Google Maps™.\u003c\/p\u003e\n\u003cp\u003eTwelve months of GPS data is stored, in normal usage. This can be conveniently transferred at any time via a USB cable to a PC or wirelessly via Bluetooth™ to a PC, tablet or smartphone to supervisors for analysis. The free-to-download C.Scope PC Toolkit and Relay smartphone App analyses the stored data.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the Locators can be paired to third party GPS Survey equipment, via the Locators in-built Bluetooth™ facilitating ‘one pass’ underground utility surveys to be undertaken.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCALIBRATION\u003cbr\u003e\u003c\/strong\u003eThe MXL4 Cable Avoidance Tools do not require periodic recalibration. A fully Automatic Daily Self Test (ADST) tests and confirms that they are functioning at their optimum level each day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUTOMATIC DAILY SELF TEST (ADST)\u003cbr\u003e\u003c\/strong\u003eThe MXL4 Locators perform an Automatic Daily Self Test (ADST). The ADST checks the functionality of the locator including the receiving aerials each day when it is first switched on. The MXT4 Transmitter also performs a comprehensive Automatic Daily Self Test (ADST)\u003c\/p\u003e\n\u003cp\u003eAt the start of each day of use, a positive Automatic Daily Self Test result gives confirmation to the operator that the kit is working at the optimum level.\u003c\/p\u003e\n\u003cp\u003eThe result of this test is recorded and stored on memory within the products in-built data files and can be downloaded onto a PC at any time within the following 12 months*.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT VALIDATION CERTIFICATION\u003cbr\u003e\u003c\/strong\u003eThese test results can be used to produce a Product Validation Certificate using the C.Scope PC Toolkit. In addition, any results of the Self Test that have been carried out in the last twelve months* are available. The PC Toolkit can also be used to view and print a copy of the original factory Calibration Certificate.\u003c\/p\u003e\n\u003cp\u003eC.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIGH RESOLUTION BACKLIT DIGITAL DISPLAY\u003cbr\u003e\u003c\/strong\u003eThe MXL4 has a large, clear and easy to read backlit LCD mounted behind a protective polycarbonate lens. The display indicates detection mode, signal peak level, depth, signal strength and battery condition. It also displays the Automatic Daily Self Test results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDETACHABLE SPEAKER\u003cbr\u003e\u003c\/strong\u003eThe speaker can be easily detached for use in noisy work environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eROBUST AND DURABLE CONSTRUCTION\u003cbr\u003e\u003c\/strong\u003eThe MXL4s twin wall construction is robust and durable. It also provides IP65 standard protection against dust and water ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSERVICE\u003cbr\u003e\u003c\/strong\u003eA complete covers off service \u0026amp; maintenance package is available for those customers who require it from C.Scope Authorised Service Centres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe MXL4 comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOverview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Mode\u003c\/li\u003e\n\u003cli\u003eRadio Mode\u003c\/li\u003e\n\u003cli\u003eTransmitter Mode:\u003cbr\u003e\u003cem\u003eSimultaneous 33+131kHz signal detection for utility avoidance\u003cbr\u003e33kHz signal detection for all purpose tracing and utility avoidance\u003cbr\u003e131kHz for optimum detection of short length, small diameter or unearthed cables\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e8kHz signal detection for tracing over longer distances\u003cbr\u003eUltra low 512Hz signal detection for specialist tracing\u003cbr\u003eUltra low 640Hz signal detection for specialist tracing\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eAll \u003c\/em\u003eScan Mode\u003c\/li\u003e\n\u003cli\u003eAccurate Depth Indication\u003c\/li\u003e\n\u003cli\u003eSignal Current Measurement\u003c\/li\u003e\n\u003cli\u003eOverload Protection\u003c\/li\u003e\n\u003cli\u003eAlarm Zone\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003ePeak Hold\u003c\/li\u003e\n\u003cli\u003eDynamic Swing Sensor\u003c\/li\u003e\n\u003cli\u003eAutomatic Daily Self Test\u003c\/li\u003e\n\u003cli\u003eData Logging of all Locator activity\u003c\/li\u003e\n\u003cli\u003eData Transfer by USB (Bluetooth\u003csup\u003eTM\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eoption)\u003c\/li\u003e\n\u003cli\u003eIn-Build GPS position logging (optional)\u003c\/li\u003e\n\u003cli\u003eConnectivity to Survey level GPS products (option)\u003c\/li\u003e\n\u003cli\u003eHigh resolution Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eNo periodic Calibration required\u003c\/li\u003e\n\u003cli\u003eProduct Validation Certificate available\u003c\/li\u003e\n\u003cli\u003eNetwork Rail Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSpec\u003c\/h3\u003e\n\u003cp\u003eThe MXL4 Multi Frequency Locator is available in two model types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMXL4-D Precision Locator\u003cbr\u003eThe C.Scope MXL4-D is a high performance digital multi-frequency Precision Pipe \u0026amp; Cable Locator with in-built Data Logging.\u003c\/li\u003e\n\u003cli\u003eMXL4-DBG Precision Locator\u003cbr\u003eThe C.Scope MXL4-DBG is a high performance digital multi-frequency Precision Pipe \u0026amp; Cable Locator with in-built Data Logging, Bluetooth™ connectivity and GPS tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth these products are designed for use with an MXT4 Multi Frequency Transmitter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003cbr\u003e\u003c\/strong\u003eMXL4 Precision Locator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Nos.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMXL4-D\u003c\/li\u003e\n\u003cli\u003eMXL4-DBG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off Switch: Spring loaded trigger switch under handle\u003c\/li\u003e\n\u003cli\u003eFunction Select Switch (FOUR position): P. Power Mode; R. Radio Mode; T. Transmitter Mode; A. AllScan Mode\u003c\/li\u003e\n\u003cli\u003eSensitivity Control\u003c\/li\u003e\n\u003cli\u003eDepth Measurement Button. Push button for live display of depth\u003c\/li\u003e\n\u003cli\u003eCurrent Measurement Button. Pushbutton for live display of Transmitter current\u003c\/li\u003e\n\u003cli\u003eFrequency Select Button. Pushbutton for Transmitter Mode frequency selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indication\u003cbr\u003e\u003c\/strong\u003eRemovable and user replaceable loudspeaker module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Indication\u003cbr\u003e\u003c\/strong\u003eMulti-segment Liquid Crystal Display indicating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSignal Strength\u003c\/li\u003e\n\u003cli\u003eMode selected\u003c\/li\u003e\n\u003cli\u003eAlarmZone™\u003c\/li\u003e\n\u003cli\u003eBattery Condition\u003c\/li\u003e\n\u003cli\u003eSelf Test Indicator\u003c\/li\u003e\n\u003cli\u003eIn Transmitter Mode, Frequency selected; Depth Measurement; Signal Current Measurement\u003c\/li\u003e\n\u003cli\u003eGPS signal detected (MXL4-DBG only)\u003c\/li\u003e\n\u003cli\u003eBluetooth™ activated (MXL4-DBG only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Logging\u003cbr\u003e\u003c\/strong\u003eInternal capacity for storing over 12months of data (in normal use) logged once per second. Data logged includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTime\/Date\u003c\/li\u003e\n\u003cli\u003eMode Sensitivity Level\u003c\/li\u003e\n\u003cli\u003eReceived Signal Level\u003c\/li\u003e\n\u003cli\u003eFrequency Depth\u003c\/li\u003e\n\u003cli\u003eSignal Current Measurement\u003c\/li\u003e\n\u003cli\u003eSelf Test Result\u003c\/li\u003e\n\u003cli\u003eSwing Indicator\u003c\/li\u003e\n\u003cli\u003eGPS position (MXL4-DBG only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth™\u003cbr\u003e\u003c\/strong\u003eBluetooth v2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eGPS\/QZSS\/GLONASS\/SBAS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Connector\u003cbr\u003e\u003c\/strong\u003eStandard USB Mini B connector in battery compartment. USB 2.0 Compatible\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelf Test\u003cbr\u003e\u003c\/strong\u003eAutomatic Daily Self Test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwing Indicator\u003cbr\u003e\u003c\/strong\u003eAudio beep to indicate incorrect use of the Locator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTransmitter Mode Frequencies\u003cbr\u003e\u003c\/strong\u003eSimultaneous 131,072Hz and 32,768Hz; 131,072Hz, 32,768Hz; 8,192Hz; 640 and 512Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eCase moulded from high impact plastic. Designed to withstand 1m (3’3”) drop onto a hard surface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries)\u003cbr\u003e\u003c\/strong\u003e2.65kg (5lb 13oz)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e720mm x 280mm x 65mm (28.3” x 11” x 2.5”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLocate Accuracy: better than 10% of depth\u003c\/li\u003e\n\u003cli\u003eDepth Accuracy: ±5% @ 1m (3’3”)\u003c\/li\u003e\n\u003cli\u003eLine Depth Measurement Range: 0.1m to 9.99m (4” to 32’)\u003c\/li\u003e\n\u003cli\u003eLine Depth Resolution: 0.1m (0.4”)\u003c\/li\u003e\n\u003cli\u003eSonde Depth Measurement Range: 0.1m to 9.99m (4” to 32’) depending on Sonde type\u003c\/li\u003e\n\u003cli\u003eSonde Depth Resolution: 0.1m (0.4”)\u003c\/li\u003e\n\u003cli\u003eCurrent Measurement: 0.01mA to 100mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 8 x ‘AA’ (LR6) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003e40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003cbr\u003e\u003c\/strong\u003e65\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNotes\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Locators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/30\/EU (EMC). Compliance has been demonstrated by testing representative samples to the relevant harmonised standards. All C.Scope Locators comply with the essential requirements and other provisions of Council Directive 2011\/65\/EU (RoHS).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMXL4-D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMXL-4DBG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Mode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Mode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator \/ Transmitter Mode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33+131kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 131kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 8kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 512Hz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 640Hz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan Mode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccurate Depth Indication\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Current Measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarmZone™\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Hold\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Swing Sensor\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Daily Self Test\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Validation Certificate\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging Rate – once per second\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2GB Memory\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via USB\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via Bluetooth™\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Built GPS position logging\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e– \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo Periodic Calibration*\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 8 x AA (LR6 Alkaline or NiMH Rechargeable)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003cbr\u003e@ 1m depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Depth\u003cbr\u003e(max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e50-400Hz\u003c\/td\u003e\n\u003ctd\u003e5mA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio\u003c\/td\u003e\n\u003ctd\u003e10kHz-30kHz\u003c\/td\u003e\n\u003ctd\u003e25µA\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eTransmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e –  33+131kHz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e33+131kHz\u003c\/td\u003e\n\u003ctd\u003e5µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 131kHz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e131kHz\u003c\/td\u003e\n\u003ctd\u003e5µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 33kHz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e5µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 8kHz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e8kHz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 512Hz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e512Hz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 640Hz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e640Hz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan\u003c\/td\u003e\n\u003ctd\u003e50Hz-33kHz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eSonde\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 33Hz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e33Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 8Hz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e8Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ci\u003e – 512Hz\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd\u003e512Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ci\u003e – 640Hz\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd\u003e640Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRodding Oscillator\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Line\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Tip \/ Sonde\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDepth Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine\u003c\/td\u003e\n\u003ctd\u003e0.2m – 3.0m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSonde\u003c\/td\u003e\n\u003ctd\u003e0.25m – 9.9m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 5% of depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGPS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Cold Start\u003c\/td\u003e\n\u003ctd\u003e30s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Hot Start\u003c\/td\u003e\n\u003ctd\u003e1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. of Channels\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003eGPS, SBAS, QZSS, Galileo, GLONASS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eBluetooth™\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion\u003c\/td\u003e\n\u003ctd\u003ev2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003ePC, Android and Apple iOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Rate\u003c\/td\u003e\n\u003ctd\u003e350kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNo Periodic Calibration\u003c\/strong\u003e. The MXL4 Locators do not require periodic recalibration. A Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. The MXL4 Locators use 8 x AA LR6 Alkaline or NiMH Rechargeable batteries sealed in a secure, fitted battery compartment. The battery pack will typically provide approximately 40 hours of service depending on use. The battery compartment also houses a spare battery holder.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDownloads\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_MXL4_4pp-1.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-selected=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cspan data-mce-fragment=\"1\"\u003eMXL4 Precision Locator Brochure\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL4_4pp-1.pdf\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/10\/18_3-CATXL4-MANUAL_1018v2.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003eMXL4 Precision Locator Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":40444194455717,"sku":"125-4-1","price":1605.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/MXL4-3Q-DLBGPS-Power-GPS-1.jpg?v=1741790498"},{"product_id":"mxl4-precision-locator-mxl4-dbg","title":"C.SCOPE - MXL4 PRECISION LOCATOR - MXL4-DBG","description":"\u003cp data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cspan\u003eThe MXL4 is a high performance multi-frequency Precision Pipe \u0026amp; Cable Locator.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIn-built Data Logging as standard. Bluetooth™ connectivity and GPS tracking options available.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDesigned for use with an MXT4 Multi Frequency Transmitter.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp\u003eThe MXL4 Precision Locator represents a significant advance in cable detecting and tracing capabilities.\u003c\/p\u003e\n\u003cp\u003eTwo versions of the MXL4 are available; the MXL4-D which has full data logging capability, and the MXL4-DBG which has full data logging capability, Bluetooth™ connectivity and GPS.\u003c\/p\u003e\n\u003cp\u003eInnovative new features have been introduced enabling the MXL4 Locator and MXT4 Transmitter to provide high-end precision performance and a far more flexible approach to pipe and cable location.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIMPROVED PERFORMANCE\u003c\/strong\u003e\u003cbr\u003eThe MXL4 is able to quickly and accurately detect, pinpoint, trace and identify the widest range of pipes and cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOVERLOAD PROTECTION\u003cbr\u003e\u003c\/strong\u003eOptimised Locator Sensitivity and Noise Rejection means that the MXL4 can deal with the highest levels of background interference found, allowing even the weakest of signals to be detected successfully.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMULTI-FREQUENCY\u003cbr\u003e\u003c\/strong\u003eThe MXT4 Transmitter now has a greater range of transmitting frequencies allowing improved long distance tracing and utility identification, even on the most congested of sites. A range of frequencies from 512\/640Hz up to 131kHz and including the simultaneous dual-frequency 33kHz and 131kHz signal output is ideal for maximising the number of buried services that can be energised and then detected. The MXL4 can apply these frequency signals without direct connection to buried services, using either a Signal Clamp or the simple induction method from ground level, providing a significant improvement in the detection of the smaller diameter or poorly earthed cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDEPTH MEASUREMENT\u003cbr\u003e\u003c\/strong\u003eThe MXL4 when used alongside an MXT4 Transmitter will measure and indicate the depth of buried pipes, cables and sondes at the push of a button.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSIGNAL CURRENT MEASUREMENT\u003cbr\u003e\u003c\/strong\u003eThe MXL4 can monitor the true strength of the MXT4 Transmitter signal applied to a buried service irrespective of its depth. This is ideal for identifying the layout of a pipe or cable network.\u003c\/p\u003e\n\u003cp\u003eINTELLIGENT NEW FEATURES:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eALARM ZONE\u003cbr\u003e\u003c\/strong\u003eAlarmZone™ alerts operators to the presence of particularly shallow pipes or cables with the exact trigger depth adjustable by the user to best suit local requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDYNAMIC SWING SENSOR\u003cbr\u003e\u003c\/strong\u003eThe Dynamic SwingSensor which gently alerts the operator if the locator is being swung excessively, potentially compromising the accuracy of any locates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePEAKHOLD\u003cbr\u003e\u003c\/strong\u003ePeakHold allows operators to quickly and confidently pinpoint the exact position of buried services\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOGGING\u003cbr\u003e\u003c\/strong\u003eThe MXL4-D and MXL4-DBG Locators have full data logging capability. A years worth of data can be stored, in normal usage, on both the Locator and the MXT4 Transmitter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOG TRANSFER via USB\u003cbr\u003e\u003c\/strong\u003eThis can be conveniently transferred at any time to supervisors for analysis via a USB cable to a PC (or wirelessly via Bluetooth™ from the DBG model only to a PC, tablet or smartphone).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA ANALYSIS\u003cbr\u003eC.SCOPE PC ‘TOOLKIT’ and ‘RELAY’ Smartphone App\u003cbr\u003e\u003c\/strong\u003eThe free-to-download C.Scope PC Toolkit and C.Scope Relay smartphone App analyses the stored data-logs into charts and graphs that illustrate all aspects of the use allowing training requirements to be quickly identified.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eThe MXL4-DBG with in-built GPS allows a record to be kept of exactly where the Locators have been used that can then be viewed in partnership with Google Earth™ or Google Maps™.\u003c\/p\u003e\n\u003cp\u003eTwelve months of GPS data is stored, in normal usage. This can be conveniently transferred at any time via a USB cable to a PC or wirelessly via Bluetooth™ to a PC, tablet or smartphone to supervisors for analysis. The free-to-download C.Scope PC Toolkit and Relay smartphone App analyses the stored data.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the Locators can be paired to third party GPS Survey equipment, via the Locators in-built Bluetooth™ facilitating ‘one pass’ underground utility surveys to be undertaken.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCALIBRATION\u003cbr\u003e\u003c\/strong\u003eThe MXL4 Cable Avoidance Tools do not require periodic recalibration. A fully Automatic Daily Self Test (ADST) tests and confirms that they are functioning at their optimum level each day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUTOMATIC DAILY SELF TEST (ADST)\u003cbr\u003e\u003c\/strong\u003eThe MXL4 Locators perform an Automatic Daily Self Test (ADST). The ADST checks the functionality of the locator including the receiving aerials each day when it is first switched on. The MXT4 Transmitter also performs a comprehensive Automatic Daily Self Test (ADST)\u003c\/p\u003e\n\u003cp\u003eAt the start of each day of use, a positive Automatic Daily Self Test result gives confirmation to the operator that the kit is working at the optimum level.\u003c\/p\u003e\n\u003cp\u003eThe result of this test is recorded and stored on memory within the products in-built data files and can be downloaded onto a PC at any time within the following 12 months*.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT VALIDATION CERTIFICATION\u003cbr\u003e\u003c\/strong\u003eThese test results can be used to produce a Product Validation Certificate using the C.Scope PC Toolkit. In addition, any results of the Self Test that have been carried out in the last twelve months* are available. The PC Toolkit can also be used to view and print a copy of the original factory Calibration Certificate.\u003c\/p\u003e\n\u003cp\u003eC.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIGH RESOLUTION BACKLIT DIGITAL DISPLAY\u003cbr\u003e\u003c\/strong\u003eThe MXL4 has a large, clear and easy to read backlit LCD mounted behind a protective polycarbonate lens. The display indicates detection mode, signal peak level, depth, signal strength and battery condition. It also displays the Automatic Daily Self Test results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDETACHABLE SPEAKER\u003cbr\u003e\u003c\/strong\u003eThe speaker can be easily detached for use in noisy work environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eROBUST AND DURABLE CONSTRUCTION\u003cbr\u003e\u003c\/strong\u003eThe MXL4s twin wall construction is robust and durable. It also provides IP65 standard protection against dust and water ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSERVICE\u003cbr\u003e\u003c\/strong\u003eA complete covers off service \u0026amp; maintenance package is available for those customers who require it from C.Scope Authorised Service Centres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe MXL4 comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOverview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Mode\u003c\/li\u003e\n\u003cli\u003eRadio Mode\u003c\/li\u003e\n\u003cli\u003eTransmitter Mode:\u003cbr\u003e\u003cem\u003eSimultaneous 33+131kHz signal detection for utility avoidance\u003cbr\u003e33kHz signal detection for all purpose tracing and utility avoidance\u003cbr\u003e131kHz for optimum detection of short length, small diameter or unearthed cables\u003c\/em\u003e\u003cbr\u003e\u003cem\u003e8kHz signal detection for tracing over longer distances\u003cbr\u003eUltra low 512Hz signal detection for specialist tracing\u003cbr\u003eUltra low 640Hz signal detection for specialist tracing\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eAll \u003c\/em\u003eScan Mode\u003c\/li\u003e\n\u003cli\u003eAccurate Depth Indication\u003c\/li\u003e\n\u003cli\u003eSignal Current Measurement\u003c\/li\u003e\n\u003cli\u003eOverload Protection\u003c\/li\u003e\n\u003cli\u003eAlarm Zone\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003ePeak Hold\u003c\/li\u003e\n\u003cli\u003eDynamic Swing Sensor\u003c\/li\u003e\n\u003cli\u003eAutomatic Daily Self Test\u003c\/li\u003e\n\u003cli\u003eData Logging of all Locator activity\u003c\/li\u003e\n\u003cli\u003eData Transfer by USB (Bluetooth\u003csup\u003eTM\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eoption)\u003c\/li\u003e\n\u003cli\u003eIn-Build GPS position logging (optional)\u003c\/li\u003e\n\u003cli\u003eConnectivity to Survey level GPS products (option)\u003c\/li\u003e\n\u003cli\u003eHigh resolution Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eNo periodic Calibration required\u003c\/li\u003e\n\u003cli\u003eProduct Validation Certificate available\u003c\/li\u003e\n\u003cli\u003eNetwork Rail Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSpec\u003c\/h3\u003e\n\u003cp\u003eThe MXL4 Multi Frequency Locator is available in two model types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMXL4-D Precision Locator\u003cbr\u003eThe C.Scope MXL4-D is a high performance digital multi-frequency Precision Pipe \u0026amp; Cable Locator with in-built Data Logging.\u003c\/li\u003e\n\u003cli\u003eMXL4-DBG Precision Locator\u003cbr\u003eThe C.Scope MXL4-DBG is a high performance digital multi-frequency Precision Pipe \u0026amp; Cable Locator with in-built Data Logging, Bluetooth™ connectivity and GPS tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth these products are designed for use with an MXT4 Multi Frequency Transmitter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003cbr\u003e\u003c\/strong\u003eMXL4 Precision Locator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Nos.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMXL4-D\u003c\/li\u003e\n\u003cli\u003eMXL4-DBG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off Switch: Spring loaded trigger switch under handle\u003c\/li\u003e\n\u003cli\u003eFunction Select Switch (FOUR position): P. Power Mode; R. Radio Mode; T. Transmitter Mode; A. AllScan Mode\u003c\/li\u003e\n\u003cli\u003eSensitivity Control\u003c\/li\u003e\n\u003cli\u003eDepth Measurement Button. Push button for live display of depth\u003c\/li\u003e\n\u003cli\u003eCurrent Measurement Button. Pushbutton for live display of Transmitter current\u003c\/li\u003e\n\u003cli\u003eFrequency Select Button. Pushbutton for Transmitter Mode frequency selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indication\u003cbr\u003e\u003c\/strong\u003eRemovable and user replaceable loudspeaker module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Indication\u003cbr\u003e\u003c\/strong\u003eMulti-segment Liquid Crystal Display indicating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSignal Strength\u003c\/li\u003e\n\u003cli\u003eMode selected\u003c\/li\u003e\n\u003cli\u003eAlarmZone™\u003c\/li\u003e\n\u003cli\u003eBattery Condition\u003c\/li\u003e\n\u003cli\u003eSelf Test Indicator\u003c\/li\u003e\n\u003cli\u003eIn Transmitter Mode, Frequency selected; Depth Measurement; Signal Current Measurement\u003c\/li\u003e\n\u003cli\u003eGPS signal detected (MXL4-DBG only)\u003c\/li\u003e\n\u003cli\u003eBluetooth™ activated (MXL4-DBG only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Logging\u003cbr\u003e\u003c\/strong\u003eInternal capacity for storing over 12months of data (in normal use) logged once per second. Data logged includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTime\/Date\u003c\/li\u003e\n\u003cli\u003eMode Sensitivity Level\u003c\/li\u003e\n\u003cli\u003eReceived Signal Level\u003c\/li\u003e\n\u003cli\u003eFrequency Depth\u003c\/li\u003e\n\u003cli\u003eSignal Current Measurement\u003c\/li\u003e\n\u003cli\u003eSelf Test Result\u003c\/li\u003e\n\u003cli\u003eSwing Indicator\u003c\/li\u003e\n\u003cli\u003eGPS position (MXL4-DBG only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth™\u003cbr\u003e\u003c\/strong\u003eBluetooth v2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eGPS\/QZSS\/GLONASS\/SBAS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Connector\u003cbr\u003e\u003c\/strong\u003eStandard USB Mini B connector in battery compartment. USB 2.0 Compatible\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelf Test\u003cbr\u003e\u003c\/strong\u003eAutomatic Daily Self Test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwing Indicator\u003cbr\u003e\u003c\/strong\u003eAudio beep to indicate incorrect use of the Locator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTransmitter Mode Frequencies\u003cbr\u003e\u003c\/strong\u003eSimultaneous 131,072Hz and 32,768Hz; 131,072Hz, 32,768Hz; 8,192Hz; 640 and 512Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eCase moulded from high impact plastic. Designed to withstand 1m (3’3”) drop onto a hard surface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries)\u003cbr\u003e\u003c\/strong\u003e2.65kg (5lb 13oz)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e720mm x 280mm x 65mm (28.3” x 11” x 2.5”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLocate Accuracy: better than 10% of depth\u003c\/li\u003e\n\u003cli\u003eDepth Accuracy: ±5% @ 1m (3’3”)\u003c\/li\u003e\n\u003cli\u003eLine Depth Measurement Range: 0.1m to 9.99m (4” to 32’)\u003c\/li\u003e\n\u003cli\u003eLine Depth Resolution: 0.1m (0.4”)\u003c\/li\u003e\n\u003cli\u003eSonde Depth Measurement Range: 0.1m to 9.99m (4” to 32’) depending on Sonde type\u003c\/li\u003e\n\u003cli\u003eSonde Depth Resolution: 0.1m (0.4”)\u003c\/li\u003e\n\u003cli\u003eCurrent Measurement: 0.01mA to 100mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 8 x ‘AA’ (LR6) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003e40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003cbr\u003e\u003c\/strong\u003e65\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNotes\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Locators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/30\/EU (EMC). Compliance has been demonstrated by testing representative samples to the relevant harmonised standards. All C.Scope Locators comply with the essential requirements and other provisions of Council Directive 2011\/65\/EU (RoHS).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMXL4-D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMXL-4DBG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Mode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Mode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator \/ Transmitter Mode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33+131kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 131kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 8kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 512Hz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 640Hz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan Mode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccurate Depth Indication\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Current Measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarmZone™\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Hold\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Swing Sensor\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Daily Self Test\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Validation Certificate\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging Rate – once per second\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2GB Memory\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via USB\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via Bluetooth™\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Built GPS position logging\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e– \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo Periodic Calibration*\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 8 x AA (LR6 Alkaline or NiMH Rechargeable)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003cbr\u003e@ 1m depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Depth\u003cbr\u003e(max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e50-400Hz\u003c\/td\u003e\n\u003ctd\u003e5mA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio\u003c\/td\u003e\n\u003ctd\u003e10kHz-30kHz\u003c\/td\u003e\n\u003ctd\u003e25µA\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eTransmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e –  33+131kHz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e33+131kHz\u003c\/td\u003e\n\u003ctd\u003e5µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 131kHz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e131kHz\u003c\/td\u003e\n\u003ctd\u003e5µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 33kHz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e5µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 8kHz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e8kHz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 512Hz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e512Hz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 640Hz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e640Hz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan\u003c\/td\u003e\n\u003ctd\u003e50Hz-33kHz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eSonde\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 33Hz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e33Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003e – 8Hz\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e8Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ci\u003e – 512Hz\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd\u003e512Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ci\u003e – 640Hz\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd\u003e640Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRodding Oscillator\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Line\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Tip \/ Sonde\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDepth Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine\u003c\/td\u003e\n\u003ctd\u003e0.2m – 3.0m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSonde\u003c\/td\u003e\n\u003ctd\u003e0.25m – 9.9m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 5% of depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGPS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Cold Start\u003c\/td\u003e\n\u003ctd\u003e30s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Hot Start\u003c\/td\u003e\n\u003ctd\u003e1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. of Channels\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003eGPS, SBAS, QZSS, Galileo, GLONASS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eBluetooth™\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion\u003c\/td\u003e\n\u003ctd\u003ev2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003ePC, Android and Apple iOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Rate\u003c\/td\u003e\n\u003ctd\u003e350kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNo Periodic Calibration\u003c\/strong\u003e. The MXL4 Locators do not require periodic recalibration. A Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. The MXL4 Locators use 8 x AA LR6 Alkaline or NiMH Rechargeable batteries sealed in a secure, fitted battery compartment. The battery pack will typically provide approximately 40 hours of service depending on use. The battery compartment also houses a spare battery holder.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDownloads\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_MXL4_4pp-1.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-selected=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cspan data-mce-fragment=\"1\"\u003eMXL4 Precision Locator Brochure\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL4_4pp-1.pdf\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/10\/18_3-CATXL4-MANUAL_1018v2.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003eMXL4 Precision Locator Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":40444250390693,"sku":"125-4-2","price":1926.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/MXL4-3Q-DLBGPS-Power-GPS-1_0ad0847d-ef77-451d-ac1d-d1523fbd6012.jpg?v=1741790534"},{"product_id":"c-scope-sga3-signal-generator","title":"C.SCOPE - SGA3 SIGNAL GENERATOR","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eThe SGA3 is a 33kHz Signal Generator designed for use alongside the CXL3 or DXL3 Cable Avoidance Tools to optimise performance and enable the detection of more buried utilities.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe C.Scope SGA3 is an affordable Signal Generator designed for use alongside a CXL3 or DXL3 Cable Avoidance Tool to make the task of cable avoidance far more effective. The C.Scope SGA3 will optimise the performance of the Cable Avoidance Tool enabling operators to locate more buried utilities including street lighting cables.\u003c\/p\u003e\n\u003cp\u003eA C.Scope SGA3 Signal Generator is a vital accompaniment to a C.Scope CXL3 and DXL3 Cable Avoidance Tool and significantly increases the number of buried services that can be detected and reduce the day-to-day risk of cable strikes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTWO SIGNAL APPLICATION TECHNIQUES\u003cbr\u003e\u003c\/strong\u003eThe 33kHz SGA3 Signal Generator can energise a buried metal pipe or cable either by ‘direct connection’ to the target pipe or cable or the simpler ‘induction’ method from above ground.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePULSED\/CONTINUOUS SIGNAL OUTPUT\u003cbr\u003e\u003c\/strong\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePulsed or Continuous signal output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows operators to switch to the Pulsed Mode at the push of a button in high interference situations and keep on tracing.\u003c\/p\u003e\n\u003cp\u003eThe SGA3 has a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eclear audible signal output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto indicate when it is in operation.\u003c\/p\u003e\n\u003cp\u003eA useful in-built\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eaudio mute control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis also included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eROBUST AND DURABLE CONSTRUCTION\u003cbr\u003e\u003c\/strong\u003eThe SGA3s twin wall construction is robust and durable. It also provides IP65 standard protection against dust and water ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eACCESSORY TRAY\u003cbr\u003e\u003c\/strong\u003eThe SGA3 Signal Generator has a large detachable accessory tray as its base. It can house not only the standard accessories (Direct Connection Leads, Earth Stake, Connection Magnets, 10m Auxiliary Earth Lead) and the Instruction Manual but also many of the optional extras such as Signal Clamps, Sondes and Signal Injectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe SGA3 comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh and Low switchable Power Output\u003c\/li\u003e\n\u003cli\u003e33kHz Signal Output\u003c\/li\u003e\n\u003cli\u003ePulsed or Continuous Output Signal\u003c\/li\u003e\n\u003cli\u003eAudio Speaker Mute\u003c\/li\u003e\n\u003cli\u003eTwo Signal Application Techniques:\u003cbr\u003e\u003cem\u003eDirect Connection\u003cbr\u003eInduction\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eIn-built Accessory Tray\u003c\/li\u003e\n\u003cli\u003eFully weatherproof design to IP65\u003c\/li\u003e\n\u003cli\u003eThree year warranty (conditions apply)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpec\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003cbr\u003e\u003c\/strong\u003eSGA3 Signal Generator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003cbr\u003e\u003c\/strong\u003e125-1-3\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003cbr\u003e\u003c\/strong\u003eAll operation is by push button control as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off\u003c\/li\u003e\n\u003cli\u003ePower Level: 2 available power levels via High and Low Power buttons\u003c\/li\u003e\n\u003cli\u003ePulse\/Continuous Output: toggles between pulse or continuous output using one push button\u003c\/li\u003e\n\u003cli\u003eAudio\/Mute: toggles between high or low level audio output using one push button\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAudio Feedback on button push\u003c\/li\u003e\n\u003cli\u003eAudio pitch drops with increasing load current in Connected Mode\u003c\/li\u003e\n\u003cli\u003eAudio pitch changes with power level in Induced Mode\u003c\/li\u003e\n\u003cli\u003eAudio output pulses to indicate Pulsed Mode\u003c\/li\u003e\n\u003cli\u003eLow battery indicated by interrupted Audio and output signal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInduced = 32,768Hz\u003c\/li\u003e\n\u003cli\u003eConnected = 32,768Hz\u003c\/li\u003e\n\u003cli\u003eCarrier Pulse Frequency: 7.5Hz (pulsed mode)\u003c\/li\u003e\n\u003cli\u003eAudio Pulse frequency: 3.75Hz (pulsed mode)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnected Mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnection Mode automatically selected when lead is plugged into socket\u003c\/li\u003e\n\u003cli\u003eMaximum Output Voltage (open circuit): 20V rms\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current (short circuit): 18mA rms\u003c\/li\u003e\n\u003cli\u003eMaximum Power: 320mW into 1000Ω load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCase moulded from high impact plastic.\u003c\/li\u003e\n\u003cli\u003eDesigned to withstand 1m (3’3”) drop onto a hard surface\u003c\/li\u003e\n\u003cli\u003eIncorporates clip on Accessory storage compartment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries, Connection Leads and Earth Stake)\u003cbr\u003e\u003c\/strong\u003e3.4kg (7 pounds 7 ounces)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (with Accessory storage compartment)\u003cbr\u003e\u003c\/strong\u003e360mm x 180mm x 230mm (14.1” x 7” x 9”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 4 x ‘D’ (LR20) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003eup to 40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Signal Generators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/53\/EU. Compliance has been demonstrated by testing representative samples to the harmonised standards EN300-330 and EN301-489. The essential radio test suites have been carried out and the equipment is in conformity with all applicable directives. All C.Scope Signal Generators comply with the RoHS directive, 2011\/65\/EU.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSGA3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Levels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Frequency\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e– 33kHz\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulsed \/ Continuous Output Signal\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeriodic Calibration Required*\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 4 x D (LR20) Alkaline or NiMH Rechargeable\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Built Accessory Tray***\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePeriodic Calibration Required\u003c\/strong\u003e. The SGA3 does require periodic recalibration.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. 4 x D LR20 Alkaline or NiMH Rechargeable batteries housed in a secure battery compartment.\u003c\/p\u003e\n\u003cp\u003e****\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIn-Built Accessory Tray\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes Direct Connection Lead, Auxiliary 10m Earth Lead, Connection Magnets, Earth Stake and Instruction Manual\u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL3_4pp-2.pdf\"\u003e\u003cem\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cspan\u003eSGA3 Signal Generator Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/17-CAT_XL3-MANUAL-1.pdf\"\u003e\u003cem\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003eSGA3 Signal Generator Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":40447042224293,"sku":"125-1-3","price":696.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/C.SCOPE-SGA3SIGNALGENERATORSGA3_TD-1.jpg?v=1741790573"},{"product_id":"mxt4-transmitter","title":"C.SCOPE - MXT4 TRANSMITTER","description":"\u003cp\u003eThe C.Scope MXT4 Transmitter is designed for use alongside an \u003ca href=\"https:\/\/www.rigginguk.co.uk\/products\/mxl4-precision-locator-mxl4-d\" target=\"_blank\" title=\"link-to-c.scope-mxl4-precision-locator-mxl4-d\" rel=\"noopener\"\u003eMXL4 Locator\u003c\/a\u003e. It enables a far more flexible approach to pipe and cable location enabling the operator to accurately detect, pinpoint, trace and identify the widest range of pipes and cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMULTI-FREQUENCY\u003cbr\u003e\u003c\/strong\u003eThe MXT4 Transmitter now has a greater range of transmitting frequencies allowing improved long distance tracing and utility identification, even on the most congested of sites. A range of frequencies from 512\/640Hz up to 131kHz and including the simultaneous dual-frequency 33kHz and 131kHz signal output is ideal for maximising the number of buried services that can be energised and then detected. The MXL4 can apply these frequency signals without direct connection to buried services, using either a Signal Clamp or the simple induction method from ground level, providing a significant improvement in the detection of the smaller diameter or poorly earthed cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE SIGNAL APPLICATION TECHNIQUES\u003cbr\u003e\u003c\/strong\u003eThe MXT4 offers three alternative ways to apply a Signal Generator signal:\u003c\/p\u003e\n\u003cp\u003eDirect Connection allows specific pipes or cables to be individually traced, identified and their depths measured. The use of Signal Clamps, Signal Injectors and Direct Connection leads make this mode the most effective method for pinpointing pipes and cables.\u003c\/p\u003e\n\u003cp\u003eIf it is difficult or inconvenient to use Direct Connection, then the Wraparound technique can be utilised to successfully energise a street or car park lighting cable.\u003c\/p\u003e\n\u003cp\u003eInduction allows the Signal Generator to induce a detectable and traceable signal to previously unknown, undetected or inaccessible underground metal pipes or cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIGH POWER SIGNAL\u003cbr\u003e\u003c\/strong\u003eThe MXT4’s fully adjustable One Watt Power Output means that deeper pipes and cables can be effectively energised and then traced over ever longer distances.\u003c\/p\u003e\n\u003cp\u003eIt also features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFOUR position power level adjustment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eso the operator has total control of how much power is in use and when.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePULSED\/CONTINUOUS SIGNAL OUTPUT\u003cbr\u003e\u003c\/strong\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePulsed or Continuous signal output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows operators to switch to the Pulsed Mode at the push of a button in high interference situations and keep on tracing. The MXT4 has a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eclear audible signal output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto indicate when it is in operation.\u003c\/p\u003e\n\u003cp\u003eA useful in-built\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eaudio mute control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis also included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOGGING\u003cbr\u003e\u003c\/strong\u003eTo compliment and support in-built data logging on the MXL4 Locator, the MXT4 Transmitter also has full data logging capability. A years worth of data can be stored, in normal usage, on both the Locator and Transmitter. This can be conveniently transferred at any time via a USB cable to a PC for analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCALIBRATION\u003cbr\u003e\u003c\/strong\u003eThe MXT4 Transmitters do not require periodic recalibration. A fully Automatic Daily Self Test (ADST) tests and confirms that they are functioning at their optimum level each day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUTOMATIC DAILY SELF TEST (ADST)\u003cbr\u003e\u003c\/strong\u003eThe MXT4 Transmitters perform a comprehensive Automatic Daily Self Test (ADST).\u003c\/p\u003e\n\u003cp\u003eAt the start of each day of use, a positive Automatic Daily Self Test result gives confirmation to the operator that the kit is working at the optimum level.\u003c\/p\u003e\n\u003cp\u003eThe result of this test is recorded and stored on memory within the products in-built data files and can be downloaded onto a PC at any time within the following 12 months*.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT VALIDATION CERTIFICATION\u003cbr\u003e\u003c\/strong\u003eThese test results can be used to produce a Product Validation Certificate using the C.Scope PC Toolkit. In addition, any results of the Self Test that have been carried out in the last twelve months* are available. The PC Toolkit can also be used to view and print a copy of the original factory Calibration Certificate.\u003c\/p\u003e\n\u003cp\u003eC.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIGH RESOLUTION BACKLIT DIGITAL DISPLAY\u003cbr\u003e\u003c\/strong\u003eThe MXT4 has a large, clear and easy to read backlit LCD mounted behind a protective polycarbonate lens. The display indicates frequency and functions selected, power level, connection quality and battery condition. It also displays the Automatic Daily Self Test results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eROBUST AND DURABLE CONSTRUCTION\u003cbr\u003e\u003c\/strong\u003eThe MXT4s twin wall construction is robust and durable. It also provides IP65 standard protection against dust and water ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eACCESSORY TRAY\u003cbr\u003e\u003c\/strong\u003eThe MXT4 Transmitter has a large detachable accessory tray as its base. It can house not only the standard accessories (Direct Connection Leads, Earth Stake, Connection Magnets, 10m Auxiliary Earth Lead) and the Instruction Manual but also many of the optional extras such as Signal Clamps, Sondes and Signal Injectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe MXT4 comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOverview\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003eOne Watt 4-level adjustable Power Output\u003c\/li\u003e\n\u003cli\u003eSix Signal Outputs:\u003cbr\u003e\u003cem\u003eSimultaneous 33+131kHz\u003cbr\u003e512Hz Signal\u003cbr\u003e640Hz Signal\u003cbr\u003e8kHz Signal\u003cbr\u003e33kHz Signal\u003cbr\u003e131kHz\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003ePulsed or Continuous Output Signal\u003c\/li\u003e\n\u003cli\u003eThree Signal Application Techniques:\u003cbr\u003e\u003cem\u003eDirect Connection \/ Wraparound \/ Induction\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eAutomatic Daily Self Test\u003c\/li\u003e\n\u003cli\u003eData Logging of all Transmitter activity\u003c\/li\u003e\n\u003cli\u003eData Transfer by USB\u003c\/li\u003e\n\u003cli\u003eHigh resolution Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eNo periodic Calibration required\u003c\/li\u003e\n\u003cli\u003eProduct Validation Certificate available\u003c\/li\u003e\n\u003cli\u003eIn-built Accessory Tray\u003c\/li\u003e\n\u003cli\u003eNetwork Rail Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSpec\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003cbr\u003e\u003c\/strong\u003eMXT4 Transmitter\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003cbr\u003e\u003c\/strong\u003eMXT4-D\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003cbr\u003e\u003c\/strong\u003eAll operation is by push button control as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off\u003c\/li\u003e\n\u003cli\u003ePower Level: Cycles through four available power levels\u003c\/li\u003e\n\u003cli\u003eFrequency: cycles through six available output frequencies\u003c\/li\u003e\n\u003cli\u003ePulse\/Continuous Output: toggles between pulse or continuous output using one push button\u003c\/li\u003e\n\u003cli\u003eAudio Output: toggles between loud, muted and silent audio output using one push button\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAudio Feedback on button push\u003c\/li\u003e\n\u003cli\u003eAudio pitch drops with increasing load current in Connected Mode\u003c\/li\u003e\n\u003cli\u003eAudio pitch changes with power level in Induced Mode\u003c\/li\u003e\n\u003cli\u003eAudio output pulses to indicate Pulsed Mode\u003c\/li\u003e\n\u003cli\u003eLow battery indicated by interrupted Audio and output signal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Indication\u003cbr\u003e\u003c\/strong\u003eMulti-segment Liquid Crystal Display indicating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Frequency\u003c\/li\u003e\n\u003cli\u003ePulse Mode\u003c\/li\u003e\n\u003cli\u003eContinuous Mode\u003c\/li\u003e\n\u003cli\u003eBattery Condition\u003c\/li\u003e\n\u003cli\u003eOutput Level (bargraph)\u003c\/li\u003e\n\u003cli\u003eSpeaker Mute\u003c\/li\u003e\n\u003cli\u003eSelf Test Result\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Connector\u003cbr\u003e\u003c\/strong\u003eStandard USB Mini B connector. USB 2.0 Compatible\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelf Test\u003cbr\u003e\u003c\/strong\u003eAutomatic Daily Self Test and manual Self Test function\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInduced = 131,072Hz and 32,768Hz; 131,072Hz, 32,768Hz and 8,192Hz\u003c\/li\u003e\n\u003cli\u003eConnected = 131,072Hz and 32,768Hz; 131,072Hz, 32,768Hz; 8,192Hz; 640 and 512Hz\u003c\/li\u003e\n\u003cli\u003eCarrier Pulse Frequency: 7.5Hz (pulsed mode)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnected Mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnection Mode automatically selected when lead is plugged into socket\u003c\/li\u003e\n\u003cli\u003eMaximum Output Voltage (open circuit): 30V rms\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current (short circuit): 65mA rms\u003c\/li\u003e\n\u003cli\u003eMaximum Power: 1W into 400Ω load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCase moulded from high impact plastic.\u003c\/li\u003e\n\u003cli\u003eDesigned to withstand 1m (3’3”) drop onto a hard surface\u003c\/li\u003e\n\u003cli\u003eIncorporates clip on accessory storage compartment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries, Connection Leads and Earth Stake)\u003cbr\u003e\u003c\/strong\u003e3.4kg (7 lb 7 oz)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (with Accessory Tray fitted)\u003cbr\u003e\u003c\/strong\u003e360mm x 180mm x 230mm (14.1” x 7” x 9”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 4 x ‘D’ (LR20) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003eup to 40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003cbr\u003e\u003c\/strong\u003e65\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNotes\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Transmitters are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/53\/EU (EMC). Compliance has been demonstrated by testing representative samples to the harmonised standards EN300-330 and EN301-489. The essential radio test suites have been carried out and the equipment is in conformity with all applicable directives. All C.Scope Transmitters comply with the essential requirements and other provisions of Council Directive 2011\/65\/EU (RoHS).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMXT4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne Watt Power\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFour Power Levels\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Frequencies\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33+131kHz (Connected and Induced)\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 131kHz (Connected and Induced)\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33kHz (Connected and Induced)\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 8kHz (Connected and Induced)\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 512Hz (Connected)\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 640Hz (Connected)\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulsed \/ Continuous Output Signal\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Connection Modes\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e– Direct Connection\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – Wraparound\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – Induction\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Daily Self Test\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via USB\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo Periodic Calibration*\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 4 x D (LR20) Alkaline or NiMH Rechargeable\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Built Accessory Tray****\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e•​\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNo Periodic Calibration\u003c\/strong\u003e. The MXT4 does not require periodic recalibration. A Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. 4 x D LR20 Alkaline or NiMH Rechargeable batteries housed in a secure battery compartment.\u003c\/p\u003e\n\u003cp\u003e****\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIn-Built Accessory Tray\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes Direct Connection Lead, Auxiliary 10m Earth Lead, Connection Magnets, Earth Stake and Instruction Manual.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDownloads\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/10\/CSCOPE_MXL4_4pp-1.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cspan data-mce-fragment=\"1\"\u003eMXT4 Transmitter Brochure\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/10\/CSCOPE_CDXL4_4pp-1.pdf\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/10\/18_3-CATXL4-MANUAL_1018v2.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-fragment=\"1\"\u003eMXT4 Transmitter Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":40447171494053,"sku":"125-4-3","price":1476.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/MXT4-1-1.jpg?v=1741790603"},{"product_id":"cs880-metal-cover-locator","title":"C.SCOPE - CS880 METAL COVER LOCATOR","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan\u003eThe CS880 Metal Cover Locator detects lost or hidden metal objects such as manhole covers and stopcock covers.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe CS880 Metal Cover Locator is a metal detector that will locate lost or hidden metal objects. It is most commonly used for locating manhole covers through tarmac and grass. It can be used successfully to find stopcock covers, steel reinforcement rods in concrete road surfaces (rebar), fuel tanks, valve heads and metal pipes or any metallic objects that are buried under tarmac or earth.\u003c\/p\u003e\n\u003cp\u003eThe CS880 is incredibly simple to operate providing a reliable, neat and quick solution to the problem of pinpointing the position of metal covers buried under earth or tarmac.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOVERVIEW\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003eSimple to use.\u003c\/li\u003e\n\u003cli\u003eAudio and visual target identification.\u003c\/li\u003e\n\u003cli\u003eInduction balance.\u003c\/li\u003e\n\u003cli\u003eTarget Hold.\u003c\/li\u003e\n\u003cli\u003eAuto power Off .\u003c\/li\u003e\n\u003cli\u003eSimple On\/Off Control Buttons.\u003c\/li\u003e\n\u003cli\u003eSealed separate battery compartment.\u003c\/li\u003e\n\u003cli\u003eWaterproof highly robust search coil.\u003c\/li\u003e\n\u003cli\u003eWaterproof construction.\u003c\/li\u003e\n\u003cli\u003eTwist lock stem length adjustment.\u003c\/li\u003e\n\u003cli\u003eLED Display.\u003c\/li\u003e\n\u003cli\u003eComfortable hand grip with arm rest.\u003c\/li\u003e\n\u003cli\u003eFascia mounted loudspeaker with socket for optional headphones.\u003c\/li\u003e\n\u003cli\u003eTwo part stem for easy stowage.\u003c\/li\u003e\n\u003cli\u003eProtective carry bag available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSPEC\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003cbr\u003e\u003c\/strong\u003eCS880 Metal Cover Locator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003cbr\u003e\u003c\/strong\u003eSimple on \/ off push buttons\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eWaterproof highly robust search coil\u003cbr\u003eWaterproof construction\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesign\u003cbr\u003e\u003c\/strong\u003eTwistlock stem length adjustment\u003cbr\u003eComfortable hand grip with arm rest\u003cbr\u003eFascia mounted loudspeaker with socket for optional headphones\u003cbr\u003eProtective carry bag available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003eSearch Head diameter 20cm\u003cbr\u003eOverall Length 107cm – 140cm\u003cbr\u003eLength from Hand Grip to Search Face: 80cm – 114cm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetection Range\u003cbr\u003e\u003c\/strong\u003eStopcock: 25cm\u003cbr\u003eValve Cover: 50cm\u003cbr\u003eCable Pit Cover: 90cm\u003cbr\u003eManhole Cover: 90cm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBatteries\u003cbr\u003e\u003c\/strong\u003eSealed separate battery compartment\u003cbr\u003e8 x AA (LR6) Alkaline clip in battery pack\u003cbr\u003eCompatible with NiMH rechargeable batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003eGreater than 100hours (typical usage)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSearch Head IP Rating\u003cbr\u003e\u003c\/strong\u003e67\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDOWNLOADS\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/03\/CS880_Manual_v5.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-fragment=\"1\"\u003eCS880 Metal Cover Locator Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL3_4pp-1-1.pdf\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/02\/CS880-Metal-Cover-Locator-Data-Sheet-1.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-fragment=\"1\"\u003eCS880 Metal Cover Locator Brochure\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":40518789464229,"sku":"125-8-1","price":252.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/cs880-metal-cover-locator.jpg?v=1741790634"},{"product_id":"cs880-carry-bag","title":"C.SCOPE - CS880 CARRY BAG","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan\u003eC.SCOPE produce a range of carry bags to transport and store Pipe and Cable Locator equipment and accessories.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe C.Scope CS880 Carry Bag is designed specifically to keep your CS880 Metal Cover Locator safe when not in use and will still have capacity to carry additional locating accessories. Larger Carry Bags for Cable Avoidance and Cable Detection products are also available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSPEC\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003cbr\u003eCS880 Carry Bag\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003cbr\u003eYCBM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cbr\u003e30 x 16 x 85cm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003cbr\u003e38 Litres\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDOWNLOADS\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/07\/16-CSCOPE-Carry-Bags-data-sheet-10-1.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eC.Scope CS880 Carry Bag Brochure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":40518830194853,"sku":"125-8-2","price":48.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/Screenshot_1_7492c976-01b3-4540-a5c7-8b1a0b05bb83.png?v=1741790637"},{"product_id":"m-scan","title":"C.SCOPE - M-SCAN Magnetometer","description":"\u003ch4 class=\"about-text\" id=\"subtext\"\u003eThe M-SCAN Magnetometer can locate deeply buried ferrous objects such as manholes, septic tanks, valve boxes, line identification markers, survey and boundary marker pegs and cast iron gas and water pipes and joints.\u003c\/h4\u003e\n\u003ch4 class=\"about-text\" id=\"subtext\"\u003eThe M-SCAN detects ferrous (magnetic) metals at a much greater depth than conventional metal detectors. It is capable of detecting objects up to 5m deep, depending on signal strength.\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe M-Scan is a battery powered Locator manufactured in heavy-duty, high-impact ABS with a robust aluminium sensor tube. It has a large, easy-to-read LCD, showing battery level, signal strength and polarity indication backed up with a clear audible response that ensures that the target can be quickly located and identified. Simple one-touch controls for volume and sensitivity are ergonomically positioned and the unique moulded case design with in-built armrest means that the M-Scan can be used for long periods without undue fatigue.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eOVERVIEW\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Sensitivity\u003c\/li\u003e\n\u003cli\u003eExcellent Detection range\u003c\/li\u003e\n\u003cli\u003e50\/60 Hz warning\u003c\/li\u003e\n\u003cli\u003eField polarity indicator\u003c\/li\u003e\n\u003cli\u003eErase feature\u003c\/li\u003e\n\u003cli\u003eNo response to aluminium, brass or copper\u003c\/li\u003e\n\u003cli\u003eVisual and audible signal strength\u003c\/li\u003e\n\u003cli\u003eMulti adjustable sensitivity\u003c\/li\u003e\n\u003cli\u003eEasy-to-use keypad\u003c\/li\u003e\n\u003cli\u003eOne-handed operation\u003c\/li\u003e\n\u003cli\u003eLow battery warning\u003c\/li\u003e\n\u003cli\u003eLong battery life – stated\u003c\/li\u003e\n\u003cli\u003eEasy access battery compartment\u003c\/li\u003e\n\u003cli\u003eRechargeable batteries option\u003c\/li\u003e\n\u003cli\u003eRobust, lightweight and ergonomic construction\u003c\/li\u003e\n\u003cli\u003eCarry case as standard\u003c\/li\u003e\n\u003cli\u003eIP65 \/ IP66\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSPEC\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003cbr\u003eM-SCAN\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003cbr\u003e125-8-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetection Depth Range\u003c\/strong\u003e\u003cbr\u003e5 m (dependent on site conditions)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMains\/ Line Detection\u003c\/strong\u003e\u003cbr\u003eVisual warning of 50-60 Hz electric field\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eErase Function\u003c\/strong\u003e\u003cbr\u003eBackground masking function allowing detection work near ferrous material\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003cbr\u003e4 levels of adjustment\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetection Resolution\u003c\/strong\u003e\u003cbr\u003e20nT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003cbr\u003eVolume, Sensitivity, On\/Off and Erase\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003cbr\u003eNumeric indication of signal amplitude, Multi segment bar graph,\u003cbr\u003ePolarity indicator, Zero field crossing indicators, Battery level and 50-60 Hz electric field warning\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSound\u003c\/strong\u003e\u003cbr\u003e8 volume levels, including mute. Frequency (pitch) varies with signal amplitude\u003cbr\u003eIn-built loudspeaker plus 3.5mm jack socket for standard headphones\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Spacing\u003c\/strong\u003e\u003cbr\u003e0.5 m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Length\u003c\/strong\u003e\u003cbr\u003e1.09 m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Tube Length\u003c\/strong\u003e\u003cbr\u003e0.73 m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eCase: Heavy duty high impact ABS (Water and dust resistant to IP65)\u003cbr\u003eSensor Tube: Epoxy sandwich coated aluminium (Waterproof and dust resistant to IP66)\u003cbr\u003eTip Protector: Heavy duty thermoplastic elastomer\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e\u003cbr\u003eEight 1.5V Cells, type AA, LR6, or equivalent. Alkaline cells recommended\u003cbr\u003eCompatible with NiMH rechargeable batteries\u003cbr\u003e100 hours battery life typical intermittent use\u003cbr\u003e4 segment visual bar Battery Indicator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cbr\u003e1.3 kg (with batteries)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003cbr\u003e-20 to +50ºC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003cbr\u003e-30 to +70ºC (batteries should be removed for storage at extremes of temperature)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCarry Bag\u003c\/strong\u003e\u003cbr\u003eProtective shoulder carry case\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDOWNLOADS\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/03\/M-SCAN-User-Guide-HiRes-1.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eM-Scan Manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/02\/M-SCAN-Data-Sheet-1.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eM-Scan Brochure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":40518855590053,"sku":"125-8-3","price":900.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/Screenshot_2_df48721c-f9ea-4420-a497-6cd99c556086.png?v=1741790641"},{"product_id":"c-scope-cxl4-cable-avoidance-tool-cxl4","title":"C.SCOPE - CXL4 CABLE AVOIDANCE TOOL - CXL4","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan\u003eThe CXL4 is a dual-frequency (33+131kHz) Cable Avoidance Tool.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIn-built Data Logging, Bluetooth™ connectivity and GPS tracking options.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDesigned for use with an SGA4 or SGV4 Signal Generator.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe CXL4 Cable Avoidance Tools from C.Scope represent a significant advance in cable detecting performance.\u003c\/p\u003e\n\u003cp\u003eThree versions of the CXL4 are available; this model the standard CXL4, the \u003ca rel=\"noopener\" title=\"c-scope-cxl4-cable-avoidance-tool-cxl4cat-d\" href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-cxl4-cable-avoidance-tool-cxl4cat-d\" target=\"_blank\"\u003eCXL4-D\u003c\/a\u003e which has full data logging capability, and the \u003ca href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-cxl4-cable-avoidance-tool-cxl4cat-dbg\" title=\"c-scope-cxl4-cable-avoidance-tool-cxl4cat-dbg\" rel=\"noopener\" target=\"_blank\"\u003eCXL4-DBG\u003c\/a\u003e which has full data logging capability, Bluetooth™ connectivity and GPS.\u003c\/p\u003e\n\u003cp\u003eInnovative new features have been introduced and the popular existing modes of detection have been enhanced to allow the CXL4 Cable Avoidance Tool to successfully detect even the hardest to find pipes and cables. Particular attention has been paid to effect better working practices and to minimise the potential for human error to impact on operating performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIMPROVED PERFORMANCE ACROSS ALL FOUR DETECTION MODES\u003cbr\u003e\u003c\/strong\u003eThe CXL4 Cable Avoidance Tool has improved performance across all modes of detection; Power, Radio, Generator and AllScan, whilst remaining easy to operate ensuring there is only a minimal need for training or retraining.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSIMULTANEOUS DUAL-FREQUENCY\u003cbr\u003e\u003c\/strong\u003eThe simultaneous dual-frequency 33kHz and 131kHz signal output of the Signal Generators is ideal for maximising the number of buried services that can be energised and then detected, providing a significant improvement in the detection of the smaller diameter or poorly earthed cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOVERLOAD PROTECTION\u003cbr\u003e\u003c\/strong\u003eOptimised Locator Sensitivity and Noise Rejection means that the CXL4 can deal with the highest levels of background interference found, allowing even the weakest of signals to be detected successfully.\u003c\/p\u003e\n\u003cp\u003eINTELLIGENT NEW FEATURES:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eALARM ZONE\u003cbr\u003e\u003c\/strong\u003eAlarmZone™ alerts operators to the presence of particularly shallow pipes or cables with the exact trigger depth adjustable by the user to best suit local requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDYNAMIC SWING SENSOR\u003cbr\u003e\u003c\/strong\u003eThe Dynamic SwingSensor which gently alerts the operator if the locator is being swung excessively, potentially compromising the accuracy of any locates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePEAKHOLD\u003cbr\u003e\u003c\/strong\u003ePeakHold allows operators to quickly and confidently pinpoint the exact position of buried services\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOGGING\u003cbr\u003e\u003c\/strong\u003eThe CXL4-D and CXL4-DBG Cable Avoidance Tools have full data logging capability. A years worth of data can be stored, in normal usage, on both the Cable Avoidance Tool and the SGV4 Signal Generator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOG TRANSFER via USB\u003cbr\u003e\u003c\/strong\u003eThis can be conveniently transferred at any time to supervisors for analysis via a USB cable to a PC (or wirelessly via Bluetooth™ from the DBG model only to a PC, tablet or smartphone).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA ANALYSIS\u003cbr\u003eC.SCOPE PC ‘TOOLKIT’ and ‘RELAY’ Smartphone App\u003cbr\u003e\u003c\/strong\u003eThe free-to-download C.Scope PC Toolkit and C.Scope Relay smartphone App analyses the stored data-logs into charts and graphs that illustrate all aspects of the use allowing training requirements to be quickly identified.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eThe CXL4-DBG with in-built GPS allows a record to be kept of exactly where the Locators have been used that can then be viewed in partnership with Google Earth™ or Google Maps™.\u003c\/p\u003e\n\u003cp\u003eTwelve months of GPS data is stored, in normal usage. This can be conveniently transferred at any time via a USB cable to a PC or wirelessly via Bluetooth™ to a PC, tablet or smartphone to supervisors for analysis. The free-to-download C.Scope PC Toolkit and Relay smartphone App analyses the stored data.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the Locators can be paired to third party GPS Survey equipment, via the Locators in-built Bluetooth™ facilitating ‘one pass’ underground utility surveys to be undertaken.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCALIBRATION\u003cbr\u003e\u003c\/strong\u003eThe CXL4 Cable Avoidance Tools do not require periodic recalibration. A fully Automatic Daily Self Test (ADST) tests and confirms that they are functioning at their optimum level each day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUTOMATIC DAILY SELF TEST (ADST)\u003cbr\u003e\u003c\/strong\u003eThe CXL4 Cable Avoidance Tools perform an Automatic Daily Self Test (ADST). The ADST checks the functionality of the locator including the receiving aerials each day when it is first switched on. The SGV4 Signal Generator also performs a comprehensive Automatic Daily Self Test (ADST).\u003c\/p\u003e\n\u003cp\u003eAt the start of each day of use, a positive Automatic Daily Self Test result gives confirmation to the operator that the kit is working at the optimum level.\u003c\/p\u003e\n\u003cp\u003eThe result of this test is recorded and stored on memory within the products in-built data files and can be downloaded onto a PC at any time within the following 12 months*.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT VALIDATION CERTIFICATION\u003cbr\u003e\u003c\/strong\u003eThese test results can be used to produce a Product Validation Certificate using the C.Scope PC Toolkit. In addition, any results of the Self Test that have been carried out in the last twelve months* are available. The PC Toolkit can also be used to view and print a copy of the original factory Calibration Certificate.\u003c\/p\u003e\n\u003cp\u003eC.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIGH RESOLUTION BACKLIT DIGITAL DISPLAY\u003cbr\u003e\u003c\/strong\u003eThe CXL4 has a large, clear and easy to read backlit LCD mounted behind a protective polycarbonate lens. The display indicates detection mode, signal peak level, depth, signal strength and battery condition. It also displays the Automatic Daily Self Test results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDETACHABLE SPEAKER\u003cbr\u003e\u003c\/strong\u003eThe speaker can be easily detached for use in noisy work environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eROBUST AND DURABLE CONSTRUCTION\u003cbr\u003e\u003c\/strong\u003eThe CXL4s twin wall construction is robust and durable. It also provides IP65 standard protection against dust and water ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSERVICE\u003cbr\u003e\u003c\/strong\u003eA complete covers off service \u0026amp; maintenance package is available for those customers who require it from C.Scope Authorised Service Centres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe CXL4 comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Mode\u003c\/li\u003e\n\u003cli\u003eRadio Mode\u003c\/li\u003e\n\u003cli\u003eGenerator Mode:\u003cbr\u003e\u003cem\u003eSimultaneous 33+131kHz\u003cbr\u003e33kHz signal detection for all purpose tracing and utility avoidance\u003cbr\u003e+ 131kHz for optimum detection for short length, small diameter or unearthed cables\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eAll \u003c\/em\u003eScan Mode\u003c\/li\u003e\n\u003cli\u003eOverload Protection\u003c\/li\u003e\n\u003cli\u003eAlarm Zone\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003ePeak Hold\u003c\/li\u003e\n\u003cli\u003eDynamic Swing Sensor\u003c\/li\u003e\n\u003cli\u003eAutomatic Daily Self Test\u003c\/li\u003e\n\u003cli\u003eData Logging of all Locator activity (option)\u003c\/li\u003e\n\u003cli\u003eData Transfer by USB. (Bluetooth\u003csup\u003eTM\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eoption)\u003c\/li\u003e\n\u003cli\u003eIn-Built GPS position logging (option)\u003c\/li\u003e\n\u003cli\u003eConnectivity to Survey level GPS products (option)\u003c\/li\u003e\n\u003cli\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eNo periodic Calibration required\u003c\/li\u003e\n\u003cli\u003eProduct Validation Certificate available\u003c\/li\u003e\n\u003cli\u003eNetwork Rail Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpec\u003c\/h3\u003e\n\u003cp\u003eThe CXL4 Cable Avoidance Tool is available in three model types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCXL4 Cable Avoidance Tool\u003cbr\u003eThe C.Scope CXL4 is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-cxl4-cable-avoidance-tool-cxl4cat-d\" title=\"c-scope-cxl4-cable-avoidance-tool-cxl4cat-d\" rel=\"noopener\" target=\"_blank\"\u003eCXL4-D Cable Avoidance Tool\u003c\/a\u003e\u003cbr\u003eThe C.Scope CXL4-D is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool with in-built Data Logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"c-scope-cxl4-cable-avoidance-tool-cxl4cat-dbg\" href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-cxl4-cable-avoidance-tool-cxl4cat-dbg\" target=\"_blank\"\u003eCXL4-DBG Cable Avoidance Tool\u003c\/a\u003e\u003cbr\u003eThe C.Scope CXL4-DBG is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool with in-built Data Logging, Bluetooth™ connectivity and GPS tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese products are designed for use with an SGA4 or an SGV4 Signal Generator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003cbr\u003e\u003c\/strong\u003eCXL4 Cable Avoidance Tool\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Nos.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSKU 125-2-1 \/\/ CXL4\u003c\/li\u003e\n\u003cli\u003eSKU 125-2-1 \/\/ CXL4-D\u003c\/li\u003e\n\u003cli\u003eSKU 125-2-3 \/\/ CXL4-DBG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off Switch: Spring loaded trigger switch under handle\u003c\/li\u003e\n\u003cli\u003eFunction Select Switch (FOUR position): P. Power Mode; R. Radio Mode; G. Generator Mode; A. AllScan Mode\u003c\/li\u003e\n\u003cli\u003eSensitivity Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indication\u003cbr\u003e\u003c\/strong\u003eRemovable and user replaceable loudspeaker module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Indication\u003cbr\u003e\u003c\/strong\u003eMulti-segment Liquid Crystal Display indicating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSignal Strength\u003c\/li\u003e\n\u003cli\u003eMode selected\u003c\/li\u003e\n\u003cli\u003eAlarmZone™\u003c\/li\u003e\n\u003cli\u003eBattery Condition\u003c\/li\u003e\n\u003cli\u003eSelf Test Indicator\u003c\/li\u003e\n\u003cli\u003eFor CXL4-DBG only, GPS signal detected, Bluetooth™ activated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Logging\u003cbr\u003e\u003c\/strong\u003eInternal capacity for storing over 12 months of data (in normal use) logged once per second. Data logged includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTime\/Date\u003c\/li\u003e\n\u003cli\u003eMode\u003c\/li\u003e\n\u003cli\u003eSensitivity Level\u003c\/li\u003e\n\u003cli\u003eReceived Signal Level\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003cli\u003eDepth\u003c\/li\u003e\n\u003cli\u003eSelf Test Result\u003c\/li\u003e\n\u003cli\u003eSwing Indicator\u003c\/li\u003e\n\u003cli\u003eGPS position (CXL4-DBG only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth™\u003cbr\u003e\u003c\/strong\u003eBluetooth v2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eGPS\/QZSS\/GLONASS\/SBAS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Connector\u003cbr\u003e\u003c\/strong\u003eStandard USB Mini B connector in battery compartment. USB 2.0 Compatible\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelf Test\u003cbr\u003e\u003c\/strong\u003eAutomatic Daily Self Test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwing Indicator\u003cbr\u003e\u003c\/strong\u003eAudio beep to indicate incorrect use of the Locator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGenerator Mode Frequencies\u003cbr\u003e\u003c\/strong\u003eSimultaneous 131,072Hz and 32,768Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eCase moulded from high impact plastic. Designed to withstand 1m (3’3”) drop onto a hard surface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries)\u003cbr\u003e\u003c\/strong\u003e2.65kg (5 lb 13 oz)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e720mm x 280mm x 65mm (28.3” x 11” x 2.5”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLocate Accuracy: better than 10% of depth\u003c\/li\u003e\n\u003cli\u003eDepth Accuracy: ±5% @ 1m (3’3”)\u003c\/li\u003e\n\u003cli\u003eLine Depth Measurement Range: 0.1m to 9.99m (4” to 32’)\u003c\/li\u003e\n\u003cli\u003eLine Depth Resolution: 0.01m (0.4”)\u003c\/li\u003e\n\u003cli\u003eSonde Depth Measurement Range: 0.1m to 9.99m (4” to 32’) depending on Sonde type\u003c\/li\u003e\n\u003cli\u003eSonde Depth Resolution: 0.01m (0.4”)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 8 x ‘AA’ (LR6) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003e40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003cbr\u003e\u003c\/strong\u003e65\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNotes\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Locators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/30\/EU (EMC). Compliance has been demonstrated by testing representative samples to the relevant harmonised standards. All C.Scope Locators comply with the essential requirements and other provisions of Council Directive 2011\/65\/EU (RoHS).\u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocator Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCXL4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCXL4-D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCXL4-DBG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator \/ Transmitter Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33+131kHz\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 131kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 8Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 512Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 640Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccurate Depth Indication\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Current Measurement\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarmZone™\u003c\/td\u003e\n\u003ctd\u003e •\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Hold\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Swing Sensor\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Daily Self Test\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Validation Certificate\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging Rate – once per second\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2GB Memory\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via USB\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via Bluetooth™\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Survey Level GPS via Bluetooth™\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Built GPS position logging\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo Periodic Calibration*\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 8 x AA (LR6) Alkaline or NiMH Rechargeable\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003ePerformance\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003cbr\u003e@ 1m depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Depth\u003cbr\u003e(max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e50-400Hz\u003c\/td\u003e\n\u003ctd\u003e5mA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio\u003c\/td\u003e\n\u003ctd\u003e10kHz-30kHz\u003c\/td\u003e\n\u003ctd\u003e25µA\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003e33+131kHz\u003c\/td\u003e\n\u003ctd\u003e5µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan\u003c\/td\u003e\n\u003ctd\u003e50Hz-33kHz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSonde\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRodding Oscillator\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Line\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Tip\/ Sonde\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Cold Start\u003c\/td\u003e\n\u003ctd\u003e30s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Hot Start\u003c\/td\u003e\n\u003ctd\u003e1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. of Channels\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003e GPS, SBAS, QZSS, Galileo, GLONASS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth™\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion\u003c\/td\u003e\n\u003ctd\u003ev2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003ePC, Android and Apple iOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Rate\u003c\/td\u003e\n\u003ctd\u003e350kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNo Periodic Calibration\u003c\/strong\u003e. The CXL4 Cable Avoidance Tools do not require periodic recalibration. The CXL4-D and CXL4-DBG Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. The CXL4 Cable Avoidance Tools use 8 x AA LR6 Alkaline or NiMH Rechargeable batteries sealed in a secure, fitted battery compartment. The battery pack will typically provide approximately 40 hours of service depending on use. The battery compartment also houses a spare battery holder.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL4_4pp-1.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cem\u003e\u003cspan data-mce-fragment=\"1\"\u003eCXL4 Cable Avoidance Tool Brochure\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/10\/18_3-CATXL4-MANUAL_1018v2.pdf\"\u003e\u003cem\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003eCXL4 Cable Avoidance Tool Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766000140672,"sku":"125-2-1","price":1130.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/c-scope-cxl4_3ei5mdaoxfwx8zrz.jpg?v=1741790398"},{"product_id":"c-scope-cxl4-cable-avoidance-tool-cxl4-d","title":"C.SCOPE - CXL4 CABLE AVOIDANCE TOOL - CXL4-D","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan\u003eThe CXL4 is a dual-frequency (33+131kHz) Cable Avoidance Tool.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIn-built Data Logging, Bluetooth™ connectivity and GPS tracking options.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDesigned for use with an SGA4 or SGV4 Signal Generator.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe CXL4 Cable Avoidance Tools from C.Scope represent a significant advance in cable detecting performance.\u003c\/p\u003e\n\u003cp\u003eThree versions of the CXL4 are available; the standard \u003ca rel=\"noopener\" title=\"c-scope-cxl4-cable-avoidance-tool-cxl4\" href=\"https:\/\/cabledrumjacks.co.uk\/products\/c-scope-cxl4-cable-avoidance-tool-cxl4\" target=\"_blank\"\u003eCXL4\u003c\/a\u003e, \u003cstrong\u003ethis model the \u003ca rel=\"noopener\" title=\"c-scope-cxl4-cable-avoidance-tool-cxl4-d\" href=\"https:\/\/cabledrumjacks.co.uk\/products\/c-scope-cxl4-cable-avoidance-tool-cxl4-d\" target=\"_blank\"\u003eCXL4-D\u003c\/a\u003e which has full data logging capability\u003c\/strong\u003e, and the \u003ca href=\"https:\/\/cabledrumjacks.co.uk\/products\/c-scope-cxl4-cable-avoidance-tool-cxl4-dbg\" title=\"c-scope-cxl4-cable-avoidance-tool-cxl4-dbg\" rel=\"noopener\" target=\"_blank\"\u003eCXL4-DBG\u003c\/a\u003e which has full data logging capability, Bluetooth™ connectivity and GPS.\u003c\/p\u003e\n\u003cp\u003eInnovative new features have been introduced and the popular existing modes of detection have been enhanced to allow the CXL4 Cable Avoidance Tool to successfully detect even the hardest to find pipes and cables. Particular attention has been paid to effect better working practices and to minimise the potential for human error to impact on operating performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIMPROVED PERFORMANCE ACROSS ALL FOUR DETECTION MODES\u003cbr\u003e\u003c\/strong\u003eThe CXL4 Cable Avoidance Tool has improved performance across all modes of detection; Power, Radio, Generator and AllScan, whilst remaining easy to operate ensuring there is only a minimal need for training or retraining.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSIMULTANEOUS DUAL-FREQUENCY\u003cbr\u003e\u003c\/strong\u003eThe simultaneous dual-frequency 33kHz and 131kHz signal output of the Signal Generators is ideal for maximising the number of buried services that can be energised and then detected, providing a significant improvement in the detection of the smaller diameter or poorly earthed cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOVERLOAD PROTECTION\u003cbr\u003e\u003c\/strong\u003eOptimised Locator Sensitivity and Noise Rejection means that the CXL4 can deal with the highest levels of background interference found, allowing even the weakest of signals to be detected successfully.\u003c\/p\u003e\n\u003cp\u003eINTELLIGENT NEW FEATURES:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eALARM ZONE\u003cbr\u003e\u003c\/strong\u003eAlarmZone™ alerts operators to the presence of particularly shallow pipes or cables with the exact trigger depth adjustable by the user to best suit local requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDYNAMIC SWING SENSOR\u003cbr\u003e\u003c\/strong\u003eThe Dynamic SwingSensor which gently alerts the operator if the locator is being swung excessively, potentially compromising the accuracy of any locates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePEAKHOLD\u003cbr\u003e\u003c\/strong\u003ePeakHold allows operators to quickly and confidently pinpoint the exact position of buried services\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOGGING\u003cbr\u003e\u003c\/strong\u003eThe CXL4-D and CXL4-DBG Cable Avoidance Tools have full data logging capability. A years worth of data can be stored, in normal usage, on both the Cable Avoidance Tool and the SGV4 Signal Generator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOG TRANSFER via USB\u003cbr\u003e\u003c\/strong\u003eThis can be conveniently transferred at any time to supervisors for analysis via a USB cable to a PC (or wirelessly via Bluetooth™ from the DBG model only to a PC, tablet or smartphone).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA ANALYSIS\u003cbr\u003eC.SCOPE PC ‘TOOLKIT’ and ‘RELAY’ Smartphone App\u003cbr\u003e\u003c\/strong\u003eThe free-to-download C.Scope PC Toolkit and C.Scope Relay smartphone App analyses the stored data-logs into charts and graphs that illustrate all aspects of the use allowing training requirements to be quickly identified.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eThe CXL4-DBG with in-built GPS allows a record to be kept of exactly where the Locators have been used that can then be viewed in partnership with Google Earth™ or Google Maps™.\u003c\/p\u003e\n\u003cp\u003eTwelve months of GPS data is stored, in normal usage. This can be conveniently transferred at any time via a USB cable to a PC or wirelessly via Bluetooth™ to a PC, tablet or smartphone to supervisors for analysis. The free-to-download C.Scope PC Toolkit and Relay smartphone App analyses the stored data.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the Locators can be paired to third party GPS Survey equipment, via the Locators in-built Bluetooth™ facilitating ‘one pass’ underground utility surveys to be undertaken.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCALIBRATION\u003cbr\u003e\u003c\/strong\u003eThe CXL4 Cable Avoidance Tools do not require periodic recalibration. A fully Automatic Daily Self Test (ADST) tests and confirms that they are functioning at their optimum level each day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUTOMATIC DAILY SELF TEST (ADST)\u003cbr\u003e\u003c\/strong\u003eThe CXL4 Cable Avoidance Tools perform an Automatic Daily Self Test (ADST). The ADST checks the functionality of the locator including the receiving aerials each day when it is first switched on. The SGV4 Signal Generator also performs a comprehensive Automatic Daily Self Test (ADST).\u003c\/p\u003e\n\u003cp\u003eAt the start of each day of use, a positive Automatic Daily Self Test result gives confirmation to the operator that the kit is working at the optimum level.\u003c\/p\u003e\n\u003cp\u003eThe result of this test is recorded and stored on memory within the products in-built data files and can be downloaded onto a PC at any time within the following 12 months*.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT VALIDATION CERTIFICATION\u003cbr\u003e\u003c\/strong\u003eThese test results can be used to produce a Product Validation Certificate using the C.Scope PC Toolkit. In addition, any results of the Self Test that have been carried out in the last twelve months* are available. The PC Toolkit can also be used to view and print a copy of the original factory Calibration Certificate.\u003c\/p\u003e\n\u003cp\u003eC.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIGH RESOLUTION BACKLIT DIGITAL DISPLAY\u003cbr\u003e\u003c\/strong\u003eThe CXL4 has a large, clear and easy to read backlit LCD mounted behind a protective polycarbonate lens. The display indicates detection mode, signal peak level, depth, signal strength and battery condition. It also displays the Automatic Daily Self Test results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDETACHABLE SPEAKER\u003cbr\u003e\u003c\/strong\u003eThe speaker can be easily detached for use in noisy work environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eROBUST AND DURABLE CONSTRUCTION\u003cbr\u003e\u003c\/strong\u003eThe CXL4s twin wall construction is robust and durable. It also provides IP65 standard protection against dust and water ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSERVICE\u003cbr\u003e\u003c\/strong\u003eA complete covers off service \u0026amp; maintenance package is available for those customers who require it from C.Scope Authorised Service Centres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe CXL4 comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Mode\u003c\/li\u003e\n\u003cli\u003eRadio Mode\u003c\/li\u003e\n\u003cli\u003eGenerator Mode:\u003cbr\u003e\u003cem\u003eSimultaneous 33+131kHz\u003cbr\u003e33kHz signal detection for all purpose tracing and utility avoidance\u003cbr\u003e+ 131kHz for optimum detection for short length, small diameter or unearthed cables\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eAll \u003c\/em\u003eScan Mode\u003c\/li\u003e\n\u003cli\u003eOverload Protection\u003c\/li\u003e\n\u003cli\u003eAlarm Zone\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003ePeak Hold\u003c\/li\u003e\n\u003cli\u003eDynamic Swing Sensor\u003c\/li\u003e\n\u003cli\u003eAutomatic Daily Self Test\u003c\/li\u003e\n\u003cli\u003eData Logging of all Locator activity (option)\u003c\/li\u003e\n\u003cli\u003eData Transfer by USB. (Bluetooth\u003csup\u003eTM\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eoption)\u003c\/li\u003e\n\u003cli\u003eIn-Built GPS position logging (option)\u003c\/li\u003e\n\u003cli\u003eConnectivity to Survey level GPS products (option)\u003c\/li\u003e\n\u003cli\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eNo periodic Calibration required\u003c\/li\u003e\n\u003cli\u003eProduct Validation Certificate available\u003c\/li\u003e\n\u003cli\u003eNetwork Rail Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpec\u003c\/h3\u003e\n\u003cp\u003eThe CXL4 Cable Avoidance Tool is available in three model types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" title=\"c-scope-cxl4-cable-avoidance-tool-cxl4\" href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-cxl4-cable-avoidance-tool-cxl4\" target=\"_blank\"\u003eCXL4 Cable Avoidance Tool\u003c\/a\u003e\u003cbr\u003eThe C.Scope CXL4 is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool.\u003c\/li\u003e\n\u003cli\u003eCXL4-D Cable Avoidance Tool\u003cbr\u003eThe C.Scope CXL4-D is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool with in-built Data Logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-cxl4-cable-avoidance-tool-cxl4-dbg\" title=\"c-scope-cxl4-cable-avoidance-tool-cxl4-dbg\" rel=\"noopener\" target=\"_blank\"\u003eCXL4-DBG Cable Avoidance Tool\u003c\/a\u003e\u003cbr\u003eThe C.Scope CXL4-DBG is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool with in-built Data Logging, Bluetooth™ connectivity and GPS tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese products are designed for use with an SGA4 or an SGV4 Signal Generator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003cbr\u003e\u003c\/strong\u003eCXL4 Cable Avoidance Tool\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Nos.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSKU 125-2-1 \/\/ CXL4\u003c\/li\u003e\n\u003cli\u003eSKU 125-2-1 \/\/ CXL4-D\u003c\/li\u003e\n\u003cli\u003eSKU 125-2-3 \/\/ CXL4-DBG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off Switch: Spring loaded trigger switch under handle\u003c\/li\u003e\n\u003cli\u003eFunction Select Switch (FOUR position): P. Power Mode; R. Radio Mode; G. Generator Mode; A. AllScan Mode\u003c\/li\u003e\n\u003cli\u003eSensitivity Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indication\u003cbr\u003e\u003c\/strong\u003eRemovable and user replaceable loudspeaker module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Indication\u003cbr\u003e\u003c\/strong\u003eMulti-segment Liquid Crystal Display indicating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSignal Strength\u003c\/li\u003e\n\u003cli\u003eMode selected\u003c\/li\u003e\n\u003cli\u003eAlarmZone™\u003c\/li\u003e\n\u003cli\u003eBattery Condition\u003c\/li\u003e\n\u003cli\u003eSelf Test Indicator\u003c\/li\u003e\n\u003cli\u003eFor CXL4-DBG only, GPS signal detected, Bluetooth™ activated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Logging\u003cbr\u003e\u003c\/strong\u003eInternal capacity for storing over 12 months of data (in normal use) logged once per second. Data logged includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTime\/Date\u003c\/li\u003e\n\u003cli\u003eMode\u003c\/li\u003e\n\u003cli\u003eSensitivity Level\u003c\/li\u003e\n\u003cli\u003eReceived Signal Level\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003cli\u003eDepth\u003c\/li\u003e\n\u003cli\u003eSelf Test Result\u003c\/li\u003e\n\u003cli\u003eSwing Indicator\u003c\/li\u003e\n\u003cli\u003eGPS position (CXL4-DBG only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth™\u003cbr\u003e\u003c\/strong\u003eBluetooth v2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eGPS\/QZSS\/GLONASS\/SBAS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Connector\u003cbr\u003e\u003c\/strong\u003eStandard USB Mini B connector in battery compartment. USB 2.0 Compatible\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelf Test\u003cbr\u003e\u003c\/strong\u003eAutomatic Daily Self Test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwing Indicator\u003cbr\u003e\u003c\/strong\u003eAudio beep to indicate incorrect use of the Locator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGenerator Mode Frequencies\u003cbr\u003e\u003c\/strong\u003eSimultaneous 131,072Hz and 32,768Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eCase moulded from high impact plastic. Designed to withstand 1m (3’3”) drop onto a hard surface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries)\u003cbr\u003e\u003c\/strong\u003e2.65kg (5 lb 13 oz)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e720mm x 280mm x 65mm (28.3” x 11” x 2.5”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLocate Accuracy: better than 10% of depth\u003c\/li\u003e\n\u003cli\u003eDepth Accuracy: ±5% @ 1m (3’3”)\u003c\/li\u003e\n\u003cli\u003eLine Depth Measurement Range: 0.1m to 9.99m (4” to 32’)\u003c\/li\u003e\n\u003cli\u003eLine Depth Resolution: 0.01m (0.4”)\u003c\/li\u003e\n\u003cli\u003eSonde Depth Measurement Range: 0.1m to 9.99m (4” to 32’) depending on Sonde type\u003c\/li\u003e\n\u003cli\u003eSonde Depth Resolution: 0.01m (0.4”)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 8 x ‘AA’ (LR6) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003e40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003cbr\u003e\u003c\/strong\u003e65\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNotes\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Locators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/30\/EU (EMC). Compliance has been demonstrated by testing representative samples to the relevant harmonised standards. All C.Scope Locators comply with the essential requirements and other provisions of Council Directive 2011\/65\/EU (RoHS).\u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocator Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCXL4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCXL4-D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCXL4-DBG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator \/ Transmitter Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33+131kHz\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 131kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 8Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 512Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 640Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccurate Depth Indication\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Current Measurement\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarmZone™\u003c\/td\u003e\n\u003ctd\u003e •\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Hold\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Swing Sensor\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Daily Self Test\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Validation Certificate\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging Rate – once per second\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2GB Memory\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via USB\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via Bluetooth™\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Survey Level GPS via Bluetooth™\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Built GPS position logging\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo Periodic Calibration*\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 8 x AA (LR6) Alkaline or NiMH Rechargeable\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003ePerformance\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003cbr\u003e@ 1m depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Depth\u003cbr\u003e(max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e50-400Hz\u003c\/td\u003e\n\u003ctd\u003e5mA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio\u003c\/td\u003e\n\u003ctd\u003e10kHz-30kHz\u003c\/td\u003e\n\u003ctd\u003e25µA\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003e33+131kHz\u003c\/td\u003e\n\u003ctd\u003e5µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan\u003c\/td\u003e\n\u003ctd\u003e50Hz-33kHz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSonde\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRodding Oscillator\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Line\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Tip\/ Sonde\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Cold Start\u003c\/td\u003e\n\u003ctd\u003e30s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Hot Start\u003c\/td\u003e\n\u003ctd\u003e1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. of Channels\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003e GPS, SBAS, QZSS, Galileo, GLONASS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth™\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion\u003c\/td\u003e\n\u003ctd\u003ev2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003ePC, Android and Apple iOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Rate\u003c\/td\u003e\n\u003ctd\u003e350kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNo Periodic Calibration\u003c\/strong\u003e. The CXL4 Cable Avoidance Tools do not require periodic recalibration. The CXL4-D and CXL4-DBG Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. The CXL4 Cable Avoidance Tools use 8 x AA LR6 Alkaline or NiMH Rechargeable batteries sealed in a secure, fitted battery compartment. The battery pack will typically provide approximately 40 hours of service depending on use. The battery compartment also houses a spare battery holder.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL4_4pp-1.pdf\"\u003e\u003cem\u003e\u003cspan\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cem\u003e\u003cspan\u003eCXL4 Cable Avoidance Tool Brochure\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/10\/18_3-CATXL4-MANUAL_1018v2.pdf\"\u003e\u003cem\u003e\u003cspan\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003eCXL4 Cable Avoidance Tool Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766002499968,"sku":"125-2-2","price":1258.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/CXL4-3Q-Power-1_ca2d8577-d791-4db4-a7c1-1886ba46605e.jpg?v=1741790416"},{"product_id":"c-scope-cxl4-cable-avoidance-tool-cxl4-dbg","title":"C.SCOPE - CXL4 CABLE AVOIDANCE TOOL - CXL4-DBG","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan\u003eThe CXL4 is a dual-frequency (33+131kHz) Cable Avoidance Tool.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIn-built Data Logging, Bluetooth™ connectivity and GPS tracking options.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDesigned for use with an SGA4 or SGV4 Signal Generator.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe CXL4 Cable Avoidance Tools from C.Scope represent a significant advance in cable detecting performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThree versions of the C.SCOPE CXL4 are available; the standard CXL4, the CXL4-D which has full data logging capability, and the CXL4-DBG which has full data logging capability, Bluetooth™ connectivity and GPS.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInnovative new features have been introduced and the popular existing modes of detection have been enhanced to allow the CXL4 Cable Avoidance Tool to successfully detect even the hardest to find pipes and cables. Particular attention has been paid to effect better working practices and to minimise the potential for human error to impact on operating performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIMPROVED PERFORMANCE ACROSS ALL FOUR DETECTION MODES\u003cbr\u003e\u003c\/strong\u003eThe CXL4 Cable Avoidance Tool has improved performance across all modes of detection; Power, Radio, Generator and AllScan, whilst remaining easy to operate ensuring there is only a minimal need for training or retraining.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSIMULTANEOUS DUAL-FREQUENCY\u003cbr\u003e\u003c\/strong\u003eThe simultaneous dual-frequency 33kHz and 131kHz signal output of the Signal Generators is ideal for maximising the number of buried services that can be energised and then detected, providing a significant improvement in the detection of the smaller diameter or poorly earthed cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOVERLOAD PROTECTION\u003cbr\u003e\u003c\/strong\u003eOptimised Locator Sensitivity and Noise Rejection means that the CXL4 can deal with the highest levels of background interference found, allowing even the weakest of signals to be detected successfully.\u003c\/p\u003e\n\u003cp\u003eINTELLIGENT NEW FEATURES:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eALARM ZONE\u003cbr\u003e\u003c\/strong\u003eAlarmZone™ alerts operators to the presence of particularly shallow pipes or cables with the exact trigger depth adjustable by the user to best suit local requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDYNAMIC SWING SENSOR\u003cbr\u003e\u003c\/strong\u003eThe Dynamic SwingSensor which gently alerts the operator if the locator is being swung excessively, potentially compromising the accuracy of any locates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePEAKHOLD\u003cbr\u003e\u003c\/strong\u003ePeakHold allows operators to quickly and confidently pinpoint the exact position of buried services\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOGGING\u003cbr\u003e\u003c\/strong\u003eThe CXL4-D and CXL4-DBG Cable Avoidance Tools have full data logging capability. A years worth of data can be stored, in normal usage, on both the Cable Avoidance Tool and the SGV4 Signal Generator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOG TRANSFER via USB\u003cbr\u003e\u003c\/strong\u003eThis can be conveniently transferred at any time to supervisors for analysis via a USB cable to a PC (or wirelessly via Bluetooth™ from the DBG model only to a PC, tablet or smartphone).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA ANALYSIS\u003cbr\u003eC.SCOPE PC ‘TOOLKIT’ and ‘RELAY’ Smartphone App\u003cbr\u003e\u003c\/strong\u003eThe free-to-download C.Scope PC Toolkit and C.Scope Relay smartphone App analyses the stored data-logs into charts and graphs that illustrate all aspects of the use allowing training requirements to be quickly identified.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eThe CXL4-DBG with in-built GPS allows a record to be kept of exactly where the Locators have been used that can then be viewed in partnership with Google Earth™ or Google Maps™.\u003c\/p\u003e\n\u003cp\u003eTwelve months of GPS data is stored, in normal usage. This can be conveniently transferred at any time via a USB cable to a PC or wirelessly via Bluetooth™ to a PC, tablet or smartphone to supervisors for analysis. The free-to-download C.Scope PC Toolkit and Relay smartphone App analyses the stored data.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the Locators can be paired to third party GPS Survey equipment, via the Locators in-built Bluetooth™ facilitating ‘one pass’ underground utility surveys to be undertaken.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCALIBRATION\u003cbr\u003e\u003c\/strong\u003eThe CXL4 Cable Avoidance Tools do not require periodic recalibration. A fully Automatic Daily Self Test (ADST) tests and confirms that they are functioning at their optimum level each day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUTOMATIC DAILY SELF TEST (ADST)\u003cbr\u003e\u003c\/strong\u003eThe CXL4 Cable Avoidance Tools perform an Automatic Daily Self Test (ADST). The ADST checks the functionality of the locator including the receiving aerials each day when it is first switched on. The SGV4 Signal Generator also performs a comprehensive Automatic Daily Self Test (ADST).\u003c\/p\u003e\n\u003cp\u003eAt the start of each day of use, a positive Automatic Daily Self Test result gives confirmation to the operator that the kit is working at the optimum level.\u003c\/p\u003e\n\u003cp\u003eThe result of this test is recorded and stored on memory within the products in-built data files and can be downloaded onto a PC at any time within the following 12 months*.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT VALIDATION CERTIFICATION\u003cbr\u003e\u003c\/strong\u003eThese test results can be used to produce a Product Validation Certificate using the C.Scope PC Toolkit. In addition, any results of the Self Test that have been carried out in the last twelve months* are available. The PC Toolkit can also be used to view and print a copy of the original factory Calibration Certificate.\u003c\/p\u003e\n\u003cp\u003eC.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIGH RESOLUTION BACKLIT DIGITAL DISPLAY\u003cbr\u003e\u003c\/strong\u003eThe CXL4 has a large, clear and easy to read backlit LCD mounted behind a protective polycarbonate lens. The display indicates detection mode, signal peak level, depth, signal strength and battery condition. It also displays the Automatic Daily Self Test results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDETACHABLE SPEAKER\u003cbr\u003e\u003c\/strong\u003eThe speaker can be easily detached for use in noisy work environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eROBUST AND DURABLE CONSTRUCTION\u003cbr\u003e\u003c\/strong\u003eThe CXL4s twin wall construction is robust and durable. It also provides IP65 standard protection against dust and water ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSERVICE\u003cbr\u003e\u003c\/strong\u003eA complete covers off service \u0026amp; maintenance package is available for those customers who require it from C.Scope Authorised Service Centres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe CXL4 comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Mode\u003c\/li\u003e\n\u003cli\u003eRadio Mode\u003c\/li\u003e\n\u003cli\u003eGenerator Mode:\u003cbr\u003e\u003cem\u003eSimultaneous 33+131kHz\u003cbr\u003e33kHz signal detection for all purpose tracing and utility avoidance\u003cbr\u003e+ 131kHz for optimum detection for short length, small diameter or unearthed cables\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eAll \u003c\/em\u003eScan Mode\u003c\/li\u003e\n\u003cli\u003eOverload Protection\u003c\/li\u003e\n\u003cli\u003eAlarm Zone\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003ePeak Hold\u003c\/li\u003e\n\u003cli\u003eDynamic Swing Sensor\u003c\/li\u003e\n\u003cli\u003eAutomatic Daily Self Test\u003c\/li\u003e\n\u003cli\u003eData Logging of all Locator activity (option)\u003c\/li\u003e\n\u003cli\u003eData Transfer by USB. (Bluetooth\u003csup\u003eTM\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eoption)\u003c\/li\u003e\n\u003cli\u003eIn-Built GPS position logging (option)\u003c\/li\u003e\n\u003cli\u003eConnectivity to Survey level GPS products (option)\u003c\/li\u003e\n\u003cli\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eNo periodic Calibration required\u003c\/li\u003e\n\u003cli\u003eProduct Validation Certificate available\u003c\/li\u003e\n\u003cli\u003eNetwork Rail Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpec\u003c\/h3\u003e\n\u003cp\u003eThe CXL4 Cable Avoidance Tool is available in three model types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-cxl4-cable-avoidance-tool-cxl4\" title=\"c-scope-cxl4-cable-avoidance-tool-cxl4\" rel=\"noopener\" target=\"_blank\"\u003eCXL4 Cable Avoidance Tool\u003c\/a\u003e\u003cbr\u003eThe C.Scope CXL4 is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-cxl4-cable-avoidance-tool-cxl4-d\" title=\"c-scope-cxl4-cable-avoidance-tool-cxl4-d\" rel=\"noopener\" target=\"_blank\"\u003eCXL4-D Cable Avoidance Tool\u003c\/a\u003e\u003cbr\u003eThe C.Scope CXL4-D is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool with in-built Data Logging.\u003c\/li\u003e\n\u003cli\u003eCXL4-DBG Cable Avoidance Tool\u003cbr\u003eThe C.Scope CXL4-DBG is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool with in-built Data Logging, Bluetooth™ connectivity and GPS tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese products are designed for use with an \u003ca href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-sga4-signal-generator\" title=\"c-scope-sga4-signal-generator\" rel=\"noopener\" target=\"_blank\"\u003eSGA4\u003c\/a\u003e or an \u003ca rel=\"noopener\" title=\"c-scope-sgv4-signal-generator\" href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-sgv4-signal-generator\" target=\"_blank\"\u003eSGV4 \u003c\/a\u003eSignal Generator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003cbr\u003e\u003c\/strong\u003eCXL4 Cable Avoidance Tool\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Nos.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSKU 125-2-1 \/\/ CXL4\u003c\/li\u003e\n\u003cli\u003eSKU 125-2-1 \/\/ CXL4-D\u003c\/li\u003e\n\u003cli\u003eSKU 125-2-3 \/\/ CXL4-DBG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off Switch: Spring loaded trigger switch under handle\u003c\/li\u003e\n\u003cli\u003eFunction Select Switch (FOUR position): P. Power Mode; R. Radio Mode; G. Generator Mode; A. AllScan Mode\u003c\/li\u003e\n\u003cli\u003eSensitivity Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indication\u003cbr\u003e\u003c\/strong\u003eRemovable and user replaceable loudspeaker module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Indication\u003cbr\u003e\u003c\/strong\u003eMulti-segment Liquid Crystal Display indicating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSignal Strength\u003c\/li\u003e\n\u003cli\u003eMode selected\u003c\/li\u003e\n\u003cli\u003eAlarmZone™\u003c\/li\u003e\n\u003cli\u003eBattery Condition\u003c\/li\u003e\n\u003cli\u003eSelf Test Indicator\u003c\/li\u003e\n\u003cli\u003eFor CXL4-DBG only, GPS signal detected, Bluetooth™ activated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Logging\u003cbr\u003e\u003c\/strong\u003eInternal capacity for storing over 12 months of data (in normal use) logged once per second. Data logged includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTime\/Date\u003c\/li\u003e\n\u003cli\u003eMode\u003c\/li\u003e\n\u003cli\u003eSensitivity Level\u003c\/li\u003e\n\u003cli\u003eReceived Signal Level\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003cli\u003eDepth\u003c\/li\u003e\n\u003cli\u003eSelf Test Result\u003c\/li\u003e\n\u003cli\u003eSwing Indicator\u003c\/li\u003e\n\u003cli\u003eGPS position (CXL4-DBG only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth™\u003cbr\u003e\u003c\/strong\u003eBluetooth v2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eGPS\/QZSS\/GLONASS\/SBAS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Connector\u003cbr\u003e\u003c\/strong\u003eStandard USB Mini B connector in battery compartment. USB 2.0 Compatible\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelf Test\u003cbr\u003e\u003c\/strong\u003eAutomatic Daily Self Test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwing Indicator\u003cbr\u003e\u003c\/strong\u003eAudio beep to indicate incorrect use of the Locator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGenerator Mode Frequencies\u003cbr\u003e\u003c\/strong\u003eSimultaneous 131,072Hz and 32,768Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eCase moulded from high impact plastic. Designed to withstand 1m (3’3”) drop onto a hard surface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries)\u003cbr\u003e\u003c\/strong\u003e2.65kg (5 lb 13 oz)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e720mm x 280mm x 65mm (28.3” x 11” x 2.5”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLocate Accuracy: better than 10% of depth\u003c\/li\u003e\n\u003cli\u003eDepth Accuracy: ±5% @ 1m (3’3”)\u003c\/li\u003e\n\u003cli\u003eLine Depth Measurement Range: 0.1m to 9.99m (4” to 32’)\u003c\/li\u003e\n\u003cli\u003eLine Depth Resolution: 0.01m (0.4”)\u003c\/li\u003e\n\u003cli\u003eSonde Depth Measurement Range: 0.1m to 9.99m (4” to 32’) depending on Sonde type\u003c\/li\u003e\n\u003cli\u003eSonde Depth Resolution: 0.01m (0.4”)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 8 x ‘AA’ (LR6) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003e40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003cbr\u003e\u003c\/strong\u003e65\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNotes\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Locators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/30\/EU (EMC). Compliance has been demonstrated by testing representative samples to the relevant harmonised standards. All C.Scope Locators comply with the essential requirements and other provisions of Council Directive 2011\/65\/EU (RoHS).\u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocator Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCXL4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCXL4-D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCXL4-DBG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator \/ Transmitter Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33+131kHz\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 131kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 8Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 512Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 640Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccurate Depth Indication\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Current Measurement\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarmZone™\u003c\/td\u003e\n\u003ctd\u003e •\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Hold\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Swing Sensor\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Daily Self Test\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Validation Certificate\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging Rate – once per second\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2GB Memory\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via USB\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via Bluetooth™\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Survey Level GPS via Bluetooth™\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Built GPS position logging\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo Periodic Calibration*\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 8 x AA (LR6) Alkaline or NiMH Rechargeable\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003ePerformance\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003cbr\u003e@ 1m depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Depth\u003cbr\u003e(max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e50-400Hz\u003c\/td\u003e\n\u003ctd\u003e5mA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio\u003c\/td\u003e\n\u003ctd\u003e10kHz-30kHz\u003c\/td\u003e\n\u003ctd\u003e25µA\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003e33+131kHz\u003c\/td\u003e\n\u003ctd\u003e5µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan\u003c\/td\u003e\n\u003ctd\u003e50Hz-33kHz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSonde\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRodding Oscillator\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Line\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Tip\/ Sonde\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Cold Start\u003c\/td\u003e\n\u003ctd\u003e30s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Hot Start\u003c\/td\u003e\n\u003ctd\u003e1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. of Channels\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003e GPS, SBAS, QZSS, Galileo, GLONASS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth™\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion\u003c\/td\u003e\n\u003ctd\u003ev2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003ePC, Android and Apple iOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Rate\u003c\/td\u003e\n\u003ctd\u003e350kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNo Periodic Calibration\u003c\/strong\u003e. The CXL4 Cable Avoidance Tools do not require periodic recalibration. The CXL4-D and CXL4-DBG Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. The CXL4 Cable Avoidance Tools use 8 x AA LR6 Alkaline or NiMH Rechargeable batteries sealed in a secure, fitted battery compartment. The battery pack will typically provide approximately 40 hours of service depending on use. The battery compartment also houses a spare battery holder.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/10\/18_3-CATXL4-MANUAL_1018v2.pdf\"\u003e\u003cem\u003e\u003cspan\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003eCXL4 Cable Avoidance Tool Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766004105600,"sku":"125-2-3","price":1540.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/CXL4-3Q-Power-1_97e73fec-c15a-49c6-a095-e5c25435f90b.jpg?v=1741790434"},{"product_id":"c-scope-dxl4-cable-avoidance-tool-dxl4-dbg","title":"C.SCOPE - DXL4 CABLE AVOIDANCE TOOL - DXL4-DBG","description":"\u003cp data-mce-fragment=\"1\" style=\"text-align: center;\"\u003e\u003cspan\u003eThe C.Scope DXL4 is a dual-frequency (33+131kHz) Cable Avoidance Tool with Depth Measurement.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIn-built Data Logging as standard. Bluetooth™ connectivity and GPS tracking options available.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDesigned for use with an SGA4 or SGV4 Signal Generator.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe DXL4 Cable Avoidance Tools from C.Scope represent a significant advance in cable detecting performance.\u003c\/p\u003e\n\u003cp\u003eTwo versions of the DXL4 are available; the DXL4-D which has full data logging capability, and the DXL4-DBG which has full data logging capability, Bluetooth™ connectivity and GPS.\u003c\/p\u003e\n\u003cp\u003eInnovative new features have been introduced and the popular existing modes of detection have been enhanced to allow the DXL4 Cable Avoidance Tool to successfully detect even the hardest to find pipes and cables. Particular attention has been paid to effect better working practices and to minimise the potential for human error to impact on operating performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIMPROVED PERFORMANCE ACROSS ALL FOUR DETECTION MODES\u003cbr\u003e\u003c\/strong\u003eThe DXL4 Cable Avoidance Tool has improved performance across all modes of detection; Power, Radio, Generator and AllScan, whilst remaining easy to operate ensuring there is only a minimal need for training or retraining.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDEPTH MEASUREMENT\u003cbr\u003e\u003c\/strong\u003eThe DXL4 when used alongside an \u003ca rel=\"noopener\" title=\"c-scope-sga4-signal-generator\" href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-sga4-signal-generator\" target=\"_blank\"\u003eSGA4\u003c\/a\u003e or \u003ca href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-sgv4-signal-generator\" title=\"c-scope-sgv4-signal-generator\" rel=\"noopener\" target=\"_blank\"\u003eSGV4\u003c\/a\u003e Signal Generator will measure and indicate the depth of buried pipes, cables and sondes at the push of a button.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSIMULTANEOUS DUAL-FREQUENCY\u003cbr\u003e\u003c\/strong\u003eThe simultaneous dual-frequency 33kHz and 131kHz signal output of the Signal Generators is ideal for maximising the number of buried services that can be energised and then detected, providing a significant improvement in the detection of the smaller diameter or poorly earthed cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOVERLOAD PROTECTION\u003cbr\u003e\u003c\/strong\u003eOptimised Locator Sensitivity and Noise Rejection means that the DXL4 can deal with the highest levels of background interference found, allowing even the weakest of signals to be detected successfully.\u003c\/p\u003e\n\u003cp\u003eINTELLIGENT NEW FEATURES:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eALARM ZONE\u003cbr\u003e\u003c\/strong\u003eAlarmZone™ alerts operators to the presence of particularly shallow pipes or cables with the exact trigger depth adjustable by the user to best suit local requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDYNAMIC SWING SENSOR\u003cbr\u003e\u003c\/strong\u003eThe Dynamic SwingSensor which gently alerts the operator if the locator is being swung excessively, potentially compromising the accuracy of any locates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePEAKHOLD\u003cbr\u003e\u003c\/strong\u003ePeakHold allows operators to quickly and confidently pinpoint the exact position of buried services\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOGGING\u003cbr\u003e\u003c\/strong\u003eThe DXL4-D and DXL4-DBG Cable Avoidance Tools have full data logging capability. A years worth of data can be stored, in normal usage, on both the Cable Avoidance Tool and the SGV4 Signal Generator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOG TRANSFER via USB\u003cbr\u003e\u003c\/strong\u003eThis can be conveniently transferred at any time to supervisors for analysis via a USB cable to a PC (or wirelessly via Bluetooth™ from the DBG model only to a PC, tablet or smartphone).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA ANALYSIS\u003cbr\u003eC.SCOPE PC ‘TOOLKIT’ and ‘RELAY’ Smartphone App\u003cbr\u003e\u003c\/strong\u003eThe free-to-download C.Scope PC Toolkit and C.Scope Relay smartphone App analyses the stored data-logs into charts and graphs that illustrate all aspects of the use allowing training requirements to be quickly identified.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eThe DXL4-DBG with in-built GPS allows a record to be kept of exactly where the Locators have been used that can then be viewed in partnership with Google Earth™ or Google Maps™.\u003c\/p\u003e\n\u003cp\u003eTwelve months of GPS data is stored, in normal usage. This can be conveniently transferred at any time via a USB cable to a PC or wirelessly via Bluetooth™ to a PC, tablet or smartphone to supervisors for analysis. The free-to-download C.Scope PC Toolkit and Relay smartphone App analyses the stored data.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the Locators can be paired to third party GPS Survey equipment, via the Locators in-built Bluetooth™ facilitating ‘one pass’ underground utility surveys to be undertaken.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCALIBRATION\u003cbr\u003e\u003c\/strong\u003eThe DXL4 Cable Avoidance Tools do not require periodic recalibration. A fully Automatic Daily Self Test (ADST) tests and confirms that they are functioning at their optimum level each day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUTOMATIC DAILY SELF TEST (ADST)\u003cbr\u003e\u003c\/strong\u003eThe DXL4 Cable Avoidance Tools perform an Automatic Daily Self Test (ADST). The ADST checks the functionality of the locator including the receiving aerials each day when it is first switched on. The SGV4 Signal Generator also performs a comprehensive Automatic Daily Self Test (ADST).\u003c\/p\u003e\n\u003cp\u003eAt the start of each day of use, a positive Automatic Daily Self Test result gives confirmation to the operator that the kit is working at the optimum level.\u003c\/p\u003e\n\u003cp\u003eThe result of this test is recorded and stored on memory within the products in-built data files and can be downloaded onto a PC at any time within the following 12 months*.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT VALIDATION CERTIFICATION\u003cbr\u003e\u003c\/strong\u003eThese test results can be used to produce a Product Validation Certificate using the C.Scope PC Toolkit. In addition, any results of the Self Test that have been carried out in the last twelve months* are available. The PC Toolkit can also be used to view and print a copy of the original factory Calibration Certificate.\u003c\/p\u003e\n\u003cp\u003eC.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal requirements.\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIGH RESOLUTION BACKLIT DIGITAL DISPLAY\u003cbr\u003e\u003c\/strong\u003eThe DXL4 has a large, clear and easy to read backlit LCD mounted behind a protective polycarbonate lens. The display indicates detection mode, signal peak level, depth, signal strength and battery condition. It also displays the Automatic Daily Self Test results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDETACHABLE SPEAKER\u003cbr\u003e\u003c\/strong\u003eThe speaker can be easily detached for use in noisy work environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eROBUST AND DURABLE CONSTRUCTION\u003cbr\u003e\u003c\/strong\u003eThe DXL4s twin wall construction is robust and durable. It also provides IP65 standard protection against dust and water ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSERVICE\u003cbr\u003e\u003c\/strong\u003eA complete covers off service \u0026amp; maintenance package is available for those customers who require it from C.Scope Authorised Service Centres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe DXL4 comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOverview\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003ePower Mode\u003c\/li\u003e\n\u003cli\u003eRadio Mode\u003c\/li\u003e\n\u003cli\u003eGenerator Mode:\u003cbr\u003e\u003cem\u003eSimultaneous 33+131kHz\u003cbr\u003e33kHz signal detection for all purpose tracing and utility avoidance\u003cbr\u003e+ 131kHz for optimum detection of short length, small diameter or unearthed cables.\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eAll \u003c\/em\u003eScan Mode\u003c\/li\u003e\n\u003cli\u003eAccurate Depth Indication\u003c\/li\u003e\n\u003cli\u003eOverload Protection\u003c\/li\u003e\n\u003cli\u003eAlarm Zone\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003ePeak Hold\u003c\/li\u003e\n\u003cli\u003eDynamic Swing Sensor\u003c\/li\u003e\n\u003cli\u003eAutomatic Daily Self Test\u003c\/li\u003e\n\u003cli\u003eData Logging of all Locator activity\u003c\/li\u003e\n\u003cli\u003eData Transfer by USB. (Bluetooth\u003csup\u003eTM\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eoption)\u003c\/li\u003e\n\u003cli\u003eIn-Built GPS position logging (option)\u003c\/li\u003e\n\u003cli\u003eConnectivity to Survey level GPS products (options)\u003c\/li\u003e\n\u003cli\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eNo periodic Calibration required\u003c\/li\u003e\n\u003cli\u003eProduct Validation Certificate available\u003c\/li\u003e\n\u003cli\u003eNetwork Rail Approved\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSpec\u003c\/h3\u003e\n\u003cp\u003eThe DXL4 depth measuring Cable Avoidance Tool is available in two model types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDXL4-D Cable Avoidance Tool\u003cbr\u003eThe C.Scope DXL4-D is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool with in-built Data Logging.\u003c\/li\u003e\n\u003cli\u003eDXL4-DBG Cable Avoidance Tool\u003cbr\u003eThe C.Scope DXL4-DBG is a high performance digital simultaneous dual-frequency (33+131kHz) Cable Avoidance Tool with in-built Data Logging, Bluetooth™ connectivity and GPS tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth these products are designed for use with an SGA4 or an SGV4 Signal Generator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003cbr\u003eDXL4 Cable Avoidance Tool\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Nos.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDXL4-D\u003c\/li\u003e\n\u003cli\u003eDXL4-DBG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off Switch: Spring loaded trigger switch under handle\u003c\/li\u003e\n\u003cli\u003eFunction Select Switch (FOUR position): P. Power Mode; R. Radio Mode; G. Generator Mode; A. AllScan Mode\u003c\/li\u003e\n\u003cli\u003eSensitivity Control\u003c\/li\u003e\n\u003cli\u003eDepth Button. Push button for live display of depth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indication\u003cbr\u003e\u003c\/strong\u003eRemovable and user replaceable loudspeaker module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Indication\u003cbr\u003e\u003c\/strong\u003eMulti-segment Liquid Crystal Display indicating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSignal Strength\u003c\/li\u003e\n\u003cli\u003eMode selected\u003c\/li\u003e\n\u003cli\u003eAlarmZone™\u003c\/li\u003e\n\u003cli\u003eBattery Condition\u003c\/li\u003e\n\u003cli\u003eSelf Test Indicator\u003c\/li\u003e\n\u003cli\u003eGPS signal detected (DXL4-DBG only)\u003c\/li\u003e\n\u003cli\u003eBluetooth™ activated (DXL4-DBG only)\u003c\/li\u003e\n\u003cli\u003eDepth Measurement (in Generator Mode)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Logging\u003cbr\u003e\u003c\/strong\u003eInternal capacity for storing over 12 months of data (in normal use) logged once per second. Data logged includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTime\/Date\u003c\/li\u003e\n\u003cli\u003eMode\u003c\/li\u003e\n\u003cli\u003eSensitivity Level\u003c\/li\u003e\n\u003cli\u003eReceived Signal Level\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003cli\u003eDepth\u003c\/li\u003e\n\u003cli\u003eSelf Test Result\u003c\/li\u003e\n\u003cli\u003eSwing Indicator\u003c\/li\u003e\n\u003cli\u003eGPS position (DXL4-DBG only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth™\u003cbr\u003e\u003c\/strong\u003eBluetooth v2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003eGPS\/QZSS\/GLONASS\/SBAS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Connector\u003cbr\u003e\u003c\/strong\u003eStandard USB Mini B connector in battery compartment. USB 2.0 Compatible\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelf Test\u003cbr\u003e\u003c\/strong\u003eAutomatic Daily Self Test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwing Indicator\u003cbr\u003e\u003c\/strong\u003eAudio beep to indicate incorrect use of the Locator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGenerator Mode Frequencies\u003cbr\u003e\u003c\/strong\u003eSimultaneous 131,072Hz and 32,768Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eCase moulded from high impact plastic. Designed to withstand 1m (3’3”) drop onto a hard surface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries)\u003cbr\u003e\u003c\/strong\u003e2.65kg (5 lb 13 oz)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e720mm x 280mm x 65mm (28.3” x 11” x 2.5”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLocate Accuracy: better than 10% of depth\u003c\/li\u003e\n\u003cli\u003eDepth Accuracy: ±5% @ 1m (3’3”)\u003c\/li\u003e\n\u003cli\u003eLine Depth Measurement Range: 0.1m to 9.99m (4” to 32’)\u003c\/li\u003e\n\u003cli\u003eLine Depth Resolution: 0.01m (0.4”)\u003c\/li\u003e\n\u003cli\u003eSonde Depth Measurement Range: 0.1m to 9.99m (4” to 32’) depending on Sonde type\u003c\/li\u003e\n\u003cli\u003eSonde Depth Resolution: 0.01m (0.4”)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 8 x ‘AA’ (LR6) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003e40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003cbr\u003e\u003c\/strong\u003e65\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNotes\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Locators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/30\/EU (EMC). Compliance has been demonstrated by testing representative samples to the relevant harmonised standards. All C.Scope Locators comply with the essential requirements and other provisions of Council Directive 2011\/65\/EU (RoHS).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDXL4-D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDXL4-DBG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator \/ Transmitter Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33+131kHz\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 131kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 8kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 512Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 640Hz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccurate Depth Indication\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Current Measurement\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarmZone™\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Hold\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Swing Sensor\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Daily Self Test\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Validation Certificate\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging Rate – once per second\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2GB Memory\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via USB\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via Bluetooth™\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Survey Level GPS via Bluetooth™\u003c\/td\u003e\n\u003ctd\u003e –\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Built GPS position logging\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo Periodic Calibration*\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 8 x AA (LR6) Alkaline or NiMH Rechargeable\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003cbr\u003e@ 1m depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Depth\u003cbr\u003e(max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e50-400Hz\u003c\/td\u003e\n\u003ctd\u003e5mA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio\u003c\/td\u003e\n\u003ctd\u003e10kHz-30kHz\u003c\/td\u003e\n\u003ctd\u003e25µA\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003e33+131kHz\u003c\/td\u003e\n\u003ctd\u003e5µA\u003c\/td\u003e\n\u003ctd\u003e5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eAll\u003c\/em\u003eScan\u003c\/td\u003e\n\u003ctd\u003e50Hz-33kHz\u003c\/td\u003e\n\u003ctd\u003e100µA\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSonde\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRodding Oscillator\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Line\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraceable Rodder – Tip \/ Sonde\u003c\/td\u003e\n\u003ctd\u003e33kHz\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e4m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cstrong\u003eDepth Measurement Range\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine\u003c\/td\u003e\n\u003ctd\u003e0.2m – 3.0m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSonde\u003c\/td\u003e\n\u003ctd\u003e0.25m – 9.9m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 5% of depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cstrong\u003eGPS\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Cold Start\u003c\/td\u003e\n\u003ctd\u003e30s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Time – Hot Start\u003c\/td\u003e\n\u003ctd\u003e1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. of Channels\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003eGPS, SBAS, QZSS, Galileo, GLONASS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cstrong\u003eBluetooth™\u003cbr\u003e\u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion\u003c\/td\u003e\n\u003ctd\u003ev2.1 (for Android) and v4.0 (for Apple iOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003ePC, Android and Apple iOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Rate\u003c\/td\u003e\n\u003ctd\u003e350kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNo Periodic Calibration\u003c\/strong\u003e. The DXL4 Cable Avoidance Tools do not require periodic recalibration. A Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. The DXL4 Cable Avoidance Tools use 8 x AA LR6 Alkaline or NiMH Rechargeable batteries sealed in a secure, fitted battery compartment. The battery pack will typically provide approximately 40 hours of service depending on use. The battery compartment also houses a spare battery holder\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDownloads\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL4_4pp-1.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003e\u003c\/span\u003e\u003c\/em\u003e D\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eCXL4 Cable Avoidance Tool Brochure\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/10\/18_3-CATXL4-MANUAL_1018v2.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003eDCXL4 Cable Avoidance Tool Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766004760960,"sku":"125-3-2","price":1734.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/DXL4-3Q-DLBGPS-Power-1_4ed4fbb0-100c-47a7-b793-1124140de68a.jpg?v=1741790476"},{"product_id":"cxl3-cable-avoidance-tool","title":"C.SCOPE - CXL3 CABLE AVOIDANCE TOOL","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eThe CXL3 is a robust and affordable analogue industry standard ‘pick-up-and-go’ Cable Avoidance Tool used to detect pipes and cables prior to excavations. Designed for use with an SGA3 Signal Generator.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe C.Scope CXL3 Cable Avoidance Tool is a robust and affordable industry standard locator used to detect buried pipes and cables prior to excavation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHitting and damaging buried services when excavating is costly and potentially very dangerous. The C.Scope Cable Avoidance Tool is the ideal ‘pick-up-and-go tool to locate buried pipes and cables, quickly and reliably, time after time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSAFE, SIMPLE, QUICK AND RELIABLE\u003cbr\u003e\u003c\/strong\u003eThe C.Scope Cable Avoidance Tool has three familiar detection modes (POWER, RADIO AND GENERATOR) to select from. Each mode provides its own specific advantages. Many operators will be familiar with these operating modes.\u003c\/p\u003e\n\u003cp\u003eThe POWER mode is the quickest way to detect most buried electricity cables by detecting the signal created by the electrical current itself.\u003c\/p\u003e\n\u003cp\u003eThe RADIO mode detects re-radiated Radio type signals that are often present on metal pipes and cables allowing their position to be determined using just the Cable Avoidance Tool alone.\u003c\/p\u003e\n\u003cp\u003eThe GENERATOR mode is used to detect the signal applied to a metal pipe or cable by a \u003ca href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-sga3-signal-generator\" title=\"link-to-purchase-c-scope-sga3-signal-generator\" rel=\"noopener\" target=\"_blank\"\u003eC.Scope SGA3\u003c\/a\u003e Signal Generator. In addition the Generator mode can be used to detect the signal being transmitted by a \u003ca rel=\"noopener\" title=\"c-scope-general-purpose-sonde-33khz\" href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-general-purpose-sonde-33khz\" target=\"_blank\"\u003eC.Scope Sonde for non-metallic pipe tracing\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eWhen combined with a C.Scope SGA3 Signal Generator and accessories, the Cable Avoidance Tool becomes a versatile, all round pipe and cable locating and tracing package. Robustly made and equipped with LCD meter, detachable loudspeaker and easy-to-operate fingertip controls the C.Scope Cable Avoidance Tool is the ideal Locator for all levels of staff who need to be able to detect buried services quickly and with confidence.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCALIBRATION\u003cbr\u003e\u003c\/strong\u003eThe CXL3 Cable Avoidance Tool does require annual recalibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe CXL3 Cable Avoidance Tool comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTRAINING\u003cbr\u003e\u003c\/strong\u003eC.Scope provide a comprehensive training course including certification for the use of all our products.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Mode\u003c\/li\u003e\n\u003cli\u003eRadio Mode\u003c\/li\u003e\n\u003cli\u003eGenerator Mode:\u003cbr\u003e\u003cem\u003e33kHz frequency detection for locating utilities\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eLiquid Crystal display (LCD)\u003c\/li\u003e\n\u003cli\u003eReal Audio response\u003c\/li\u003e\n\u003cli\u003eProvision for spare battery storage\u003c\/li\u003e\n\u003cli\u003eRetractable loudspeaker\u003c\/li\u003e\n\u003cli\u003eAnnual Calibration checks required\u003c\/li\u003e\n\u003cli\u003eFully weatherproof design to IP65\u003c\/li\u003e\n\u003cli\u003eThree year warranty (conditions apply)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpec\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003cbr\u003eCXL3 Cable Avoidance Tool\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003cbr\u003e\u003c\/strong\u003e125-1-1\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off Switch: Spring loaded trigger switch under handle\u003c\/li\u003e\n\u003cli\u003eFunction Select Switch (Three position): P – Power Mode; R – Radio Mode; G – Generator Mode\u003c\/li\u003e\n\u003cli\u003eSensitivity Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indication\u003cbr\u003e\u003c\/strong\u003eRemovable and user replaceable loudspeaker module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Indication\u003cbr\u003e\u003c\/strong\u003eMulti-segment Liquid Crystal Display indicating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSignal Strength\u003c\/li\u003e\n\u003cli\u003eMode selected\u003c\/li\u003e\n\u003cli\u003eBattery Condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eCase moulded from high impact plastic. Designed to withstand 1m (3’3”) drop onto a hard surface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries)\u003cbr\u003e\u003c\/strong\u003e2.9kg (6 pounds 6 ounces)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e720mm x 270mm x 63mm (28.3” x 10.6” x 2.4”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLocate Accuracy: better than 10% of depth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 8 x ‘AA’ (LR6) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003e40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003cbr\u003e\u003c\/strong\u003e65\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Locators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/30\/EU. Compliance has been demonstrated by testing representative samples to the relevant harmonised standards. All C.Scope Locators comply with the RoHS directive, 2011\/65\/EU.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocator Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCXL3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Mode\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e– 33kHz\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeriodic Calibration Required*\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 8 x AA (LR6) Alkaline or NiMH Rechargeable\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePeriodic Calibration\u003c\/strong\u003e. The CXL3 Cable Avoidance Tool requires periodic calibration.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year Warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. The CXL3 Cable Avoidance Tool uses 8 x AA LR6 Alkaline or NiMH Rechargeable batteries sealed in a secure, fitted battery compartment. The battery pack will typically provide approximately 40 hours of service depending on use. The battery compartment also houses a spare battery holder.\u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL3_4pp-1-1.pdf\"\u003e\u003cem\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cem\u003e\u003cspan\u003eCXL3 Cable Avoidance Tool Brochure\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/17-CAT_XL3-MANUAL-1.pdf\"\u003e\u003cem\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003eCXL3 Cable Avoidance Tool Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766007972224,"sku":"125-1-1","price":750.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/Screenshot_1_2aa779ff-9725-4ac0-be68-d6615cc22ee6.png?v=1741790551"},{"product_id":"dxl3-cable-avoidance-tool","title":"C.SCOPE - DXL3 CABLE AVOIDANCE TOOL","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eThe DXL3 is a robust and affordable analogue industry standard ‘pick-up-and-go’ Cable Avoidance Tool with depth measurement used to detect pipes and cables prior to excavations. Designed for use with an \u003ca rel=\"noopener\" title=\"link-to-purchase-c-scope-sga3-signal-generator\" href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-sga3-signal-generator\" target=\"_blank\"\u003eSGA3 Signal Generator\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe C.Scope DXL3 depth measuring Cable Avoidance Tool is a robust and affordable industry standard locator used to detect buried pipes and cables prior to excavation.\u003c\/p\u003e\n\u003cp\u003eHitting and damaging buried services when excavating is costly and potentially very dangerous. The C.Scope Cable Avoidance Tool is the ideal ‘pick-up-and-go tool to locate buried pipes and cables, quickly and reliably, time after time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSAFE, SIMPLE, QUICK AND RELIABLE\u003cbr\u003e\u003c\/strong\u003eThe C.Scope Cable Avoidance Tool has three familiar detection modes (POWER, RADIO AND GENERATOR) to select from. Each mode provides its own specific advantages. Many operators will be familiar with these operating modes.\u003c\/p\u003e\n\u003cp\u003eThe POWER mode is the quickest way to detect most buried electricity cables by detecting the signal created by the electrical current itself.\u003c\/p\u003e\n\u003cp\u003eThe RADIO mode detects re-radiated Radio type signals that are often present on metal pipes and cables allowing their position to be determined using just the Cable Avoidance Tool alone.\u003c\/p\u003e\n\u003cp\u003eThe GENERATOR mode is used to detect the signal applied to a metal pipe or cable by a \u003ca rel=\"noopener\" title=\"c-scope-sga3-signal-generator\" href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-sga3-signal-generator\" target=\"_blank\"\u003eC.Scope SGA3 Signal Generator\u003c\/a\u003e. In addition the Generator mode can be used to detect the signal being transmitted by a \u003ca rel=\"noopener\" title=\"c-scope-general-purpose-sonde-33khz\" href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-general-purpose-sonde-33khz\" target=\"_blank\"\u003eC.Scope Sonde for non-metallic pipe tracing\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDEPTH MEASUREMENT\u003cbr\u003e\u003c\/strong\u003eThe DXL3 Cable Avoidance Tool also features the addition of a simple to operate Depth Measurement button on the top of the product (for use in GENERATOR Mode).\u003c\/p\u003e\n\u003cp\u003eWhen combined with a C.Scope SGA3 Signal Generator and accessories, the Cable Avoidance Tool becomes a versatile, all round pipe and cable locating and tracing package. Robustly made and equipped with LCD meter, detachable loudspeaker and easy-to-operate fingertip controls the C.Scope Cable Avoidance Tool is the ideal Locator for all levels of staff who need to be able to detect buried services quickly and with confidence.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCALIBRATION\u003cbr\u003e\u003c\/strong\u003eThe DXL3 Cable Avoidance Tool does require annual recalibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe DXL3 Cable Avoidance Tool comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTRAINING\u003cbr\u003e\u003c\/strong\u003eC.Scope provide a comprehensive training course including certification for the use of all our products.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower Mode\u003c\/li\u003e\n\u003cli\u003eRadio Mode\u003c\/li\u003e\n\u003cli\u003eGenerator Mode:\u003cbr\u003e\u003cem\u003e33kHz frequency detection for locating utilities\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eDepth Measurement\u003c\/li\u003e\n\u003cli\u003eLiquid Crystal display (LCD)\u003c\/li\u003e\n\u003cli\u003eReal Audio response\u003c\/li\u003e\n\u003cli\u003eProvision for spare battery storage\u003c\/li\u003e\n\u003cli\u003eRetractable loudspeaker\u003c\/li\u003e\n\u003cli\u003eAnnual Calibration checks required\u003c\/li\u003e\n\u003cli\u003eFully weatherproof design to IP65\u003c\/li\u003e\n\u003cli\u003eThree year warranty (conditions apply)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpec\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003cbr\u003e\u003c\/strong\u003eDXL3 Cable Avoidance Tool\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003cbr\u003e\u003c\/strong\u003e125-1-2\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off Switch: Spring loaded trigger switch under handle\u003c\/li\u003e\n\u003cli\u003eFunction Select Switch (Three position): P – Power Mode; R – Radio Mode; G – Generator Mode\u003c\/li\u003e\n\u003cli\u003eSensitivity Control\u003c\/li\u003e\n\u003cli\u003eDepth Button: Push button for live display of depth – DXL3 only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indication\u003cbr\u003e\u003c\/strong\u003eRemovable and user replaceable loudspeaker module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Indication\u003cbr\u003e\u003c\/strong\u003eMulti-segment Liquid Crystal Display indicating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSignal Strength; Mode selected; Battery Condition;\u003c\/li\u003e\n\u003cli\u003eDepth Measurement (in Generator Mode) – DXL3 only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eCase moulded from high impact plastic. Designed to withstand 1m (3’3”) drop onto a hard surface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries)\u003cbr\u003e\u003c\/strong\u003e2.9kg (6 pounds 6 ounces)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e720mm x 270mm x 63mm (28.3” x 10.6” x 2.4”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLocate Accuracy: better than 10% of depth\u003c\/li\u003e\n\u003cli\u003eDepth Accuracy: ±5% @ 1m (3’3”) – DXL3 only\u003c\/li\u003e\n\u003cli\u003eDepth Measurement Range: Line 0.2m to 3m (8” to 10’)\u003c\/li\u003e\n\u003cli\u003eDepth Resolution: Line 0.05m\u003c\/li\u003e\n\u003cli\u003eDepth Measurement Range: Sonde 0.85m to 4.5m (2’9” to 15’) – depending on Sonde type\u003c\/li\u003e\n\u003cli\u003eDepth Resolution: Sonde 0.15m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 8 x ‘AA’ (LR6) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003e40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003cbr\u003e\u003c\/strong\u003e65\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Locators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/30\/EU. Compliance has been demonstrated by testing representative samples to the relevant harmonised standards. All C.Scope Locators comply with the RoHS directive, 2011\/65\/EU.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocator Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDXL3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Mode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio Mode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Mode\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e– 33kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccurate Depth Indication\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeriodic Calibration Required*\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 8 x AA (LR6) Alkaline or NiMH Rechargeable\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePeriodic Calibration\u003c\/strong\u003e. The DXL3 Cable Avoidance Tool requires periodic calibration.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. The DXL3 Cable Avoidance Tool uses 8 x AA LR6 Alkaline or NiMH Rechargeable batteries sealed in a secure, fitted battery compartment. The battery pack will typically provide approximately 40 hours of service depending on use. The battery compartment also houses a spare battery holder.\u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/17-CAT_XL3-MANUAL-1.pdf\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003eDXL3 Cable Avoidance Tool Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766008168832,"sku":"125-1-2","price":846.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/DXL3-3Q-1.jpg?v=1741790564"},{"product_id":"c-scope-sga4-signal-generator","title":"C.SCOPE - SGA4 SIGNAL GENERATOR","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eThe SGA4 is a One Watt dual-frequency (33+131kHz) Signal Generator. Designed for use with a CXL4 or DXL4 Cable Avoidance Tool.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe C.Scope SGA4 is an affordable Signal Generator designed for use alongside a CXL4 or DXL4 Cable Avoidance Tool. It enables significantly more underground utilities to be detected including street lighting cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSIMULTANEOUS DUAL-FREQUENCY\u003cbr\u003e\u003c\/strong\u003eThe simultaneous dual-frequency 33kHz and 131kHz signal output of the Signal Generators is ideal for maximising the number of buried services that can be energised and then detected.\u003c\/p\u003e\n\u003cp\u003eThe SGA4 Signal Generator can apply the dual frequency signal without direct connection to buried services, using either a Signal Clamp or the simple induction method from ground level, providing a significant improvement in the detection of the smaller diameter or poorly earthed cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE SIGNAL APPLICATION TECHNIQUES\u003cbr\u003e\u003c\/strong\u003eThe SGA4 offers three alternative ways to apply a Signal Generator signal:\u003c\/p\u003e\n\u003cp\u003eDirect Connection allows specific pipes or cables to be individually traced, identified and their depths measured. The use of Signal Clamps, Signal Injectors and Direct Connection leads make this mode the most effective method for pinpointing pipes and cables.\u003c\/p\u003e\n\u003cp\u003eIf it is difficult or inconvenient to use Direct Connection, then the Wraparound technique can be utilised to successfully energise a street or car park lighting cable.\u003c\/p\u003e\n\u003cp\u003eInduction allows the Signal Generator to induce a detectable and traceable signal to previously unknown, undetected or inaccessible underground metal pipes or cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIGH POWER SIGNAL\u003cbr\u003e\u003c\/strong\u003eThe fully adjustable One Watt Power Output of the SGA4 means that deeper and less conducting pipes and cables can be effectively energised and then traced over ever longer distances.\u003c\/p\u003e\n\u003cp\u003eIt also features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo position power levels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eso the operator has some control of how much power is in use and when.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePULSED\/CONTINUOUS SIGNAL OUTPUT\u003cbr\u003e\u003c\/strong\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePulsed or Continuous signal output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows operators to switch to the Pulsed Mode at the push of a button in high interference situations and keep on tracing. The SGA4 has a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eclear audible signal output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto indicate when it is in operation.\u003c\/p\u003e\n\u003cp\u003eA useful in-built\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eaudio mute control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis also included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eROBUST AND DURABLE CONSTRUCTION\u003cbr\u003e\u003c\/strong\u003eThe SGA4s twin wall construction is robust and durable. It also provides IP65 standard protection against dust and water ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eACCESSORY TRAY\u003cbr\u003e\u003c\/strong\u003eThe SGA4 Signal Generator has a large detachable accessory tray as its base. It can house not only the standard accessories (Direct Connection Leads, Earth Stake, Connection Magnets, 10m Auxiliary Earth Lead) and the Instruction Manual but also many of the optional extras such as Signal Clamps, Sondes and Signal Injectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe SGA4 comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Watt High\/Low Power Output\u003c\/li\u003e\n\u003cli\u003eSimultaneous 33+131kHz Signal\u003c\/li\u003e\n\u003cli\u003ePulsed or Continuous Output Signal\u003c\/li\u003e\n\u003cli\u003eThree Signal Application Techniques:\u003cbr\u003e\u003cem\u003eDirect Connection \/ Wraparound \/ Induction\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eNo periodic Calibration required\u003c\/li\u003e\n\u003cli\u003eIn-built Accessory Tray\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpec\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003cbr\u003e\u003c\/strong\u003eSGA4 Signal Generator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003cbr\u003e\u003c\/strong\u003e125-2-4\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003cbr\u003e\u003c\/strong\u003eAll operation is by push button control as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off\u003c\/li\u003e\n\u003cli\u003ePower Level: 2 available power levels via High and Low Power buttons\u003c\/li\u003e\n\u003cli\u003ePulse\/Continuous Output: toggles between pulse or continuous output using one push button\u003c\/li\u003e\n\u003cli\u003eAudio\/Mute: toggles between loud or muted audio output using one push button\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAudio Feedback on button push\u003c\/li\u003e\n\u003cli\u003eAudio pitch drops with increasing load current in Connected Mode\u003c\/li\u003e\n\u003cli\u003eAudio pitch changes with power level in Induced Mode\u003c\/li\u003e\n\u003cli\u003eAudio output pulses to indicate Pulsed Mode\u003c\/li\u003e\n\u003cli\u003eLow battery indicated by interrupted Audio and output signal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInduced = 32,768Hz\u003c\/li\u003e\n\u003cli\u003eConnected = 131,072Hz and 32,768Hz\u003c\/li\u003e\n\u003cli\u003eCarrier Pulse Frequency: 7.5Hz (pulsed mode)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnected Mode\u003cbr\u003e\u003c\/strong\u003eConnection Mode automatically selected when lead is plugged into socket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Output Voltage (open circuit)\u003cbr\u003e\u003c\/strong\u003e28V rms\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Output Current (short circuit)\u003cbr\u003e\u003c\/strong\u003e65mA rms\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Power\u003cbr\u003e\u003c\/strong\u003e1W into 400Ω load\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCase moulded from high impact plastic\u003c\/li\u003e\n\u003cli\u003eDesigned to withstand 1m (3’3”) drop onto a hard surface\u003c\/li\u003e\n\u003cli\u003eIncorporates clip on accessory storage compartment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries, Connection Leads and Earth Stake)\u003cbr\u003e\u003c\/strong\u003e3.4kg (7 lb 7 oz)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (with Accessory Tray fitted)\u003cbr\u003e\u003c\/strong\u003e360mm x 180mm x 230mm (14.1” x 7” x 9”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 4 x ‘D’ (LR20) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003eup to 40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003cbr\u003e\u003c\/strong\u003e65\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNotes:\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Signal Generators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/53\/EU (EMC). Compliance has been demonstrated by testing representative samples to the harmonised standards EN300-330 and EN301-489. The essential radio test suites have been carried out and the equipment is in conformity with all applicable directives. All C.Scope Signal Generators comply with the essential requirements and other provisions of Council Directive 2011\/65\/EU (RoHS).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellspacing=\"7\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSGA4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne Watt Power\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Levels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Frequencies:\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33+131kHz (Connected at 33+131kHz. Induced at 33kHz only.)\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 131kHz (Connected and Induced)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33kHz (Connected and Induced)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 8kHz (Connected and Induced)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 512Hz (Connected)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 640Hz (Connected)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulsed \/ Continuous Output Signal\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Connection Modes:\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – Direct Connection\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – Wraparound\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – Induction\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Daily Self Test\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via USB\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo Periodic Calibration*\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 4 x D (LR20) Alkaline or NiMH Rechargeable\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Built Accessory Tray****\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNo Periodic Calibration\u003c\/strong\u003e. The SGA4 does not require periodic recalibration. A Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. 4 x D LR20 Alkaline or NiMH Rechargeable batteries housed in a secure battery compartment.\u003c\/p\u003e\n\u003cp\u003e****\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIn-Built Accessory Tray\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes Direct Connection Lead, Auxiliary 10m Earth Lead, Connection Magnets, Earth Stake and Instruction Manual.\u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/10\/18_3-CATXL4-MANUAL_1018v2.pdf\"\u003e\u003cem\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003eSGA4 Signal Generator Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766008430976,"sku":"125-2-4","price":958.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/C.SCOPE-SGA4SIGNALGENERATORSGA4-1-1.jpg?v=1741790585"},{"product_id":"c-scope-sgv4-signal-generator","title":"C.SCOPE - SGV4 SIGNAL GENERATOR","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan\u003eThe C.Scope SGV4 is a One Watt dual-frequency (33+131kHz) Signal Generator with in-built Data Logging. \u003c\/span\u003e\u003cspan\u003eDesigned for use with a CXL4 or DXL4 Cable Avoidance Tool.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe C.Scope SGV4 Signal Generator is designed for use alongside a \u003ca rel=\"noopener\" title=\"c-scope-cxl4-cable-avoidance-tool-cxl4\" href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-cxl4-cable-avoidance-tool-cxl4\" target=\"_blank\"\u003eCXL4\u003c\/a\u003e or \u003ca href=\"https:\/\/www.rigginguk.co.uk\/products\/c-scope-dxl4-cable-avoidance-tool-dxl4-dbg\" target=\"_blank\" title=\"c-scope-dxl4-cable-avoidance-tool-dxl4-dbg\" rel=\"noopener\"\u003eDXL4\u003c\/a\u003e Cable Avoidance Tool. It enables significantly more underground utilities to be detected including street lighting cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSIMULTANEOUS DUAL-FREQUENCY\u003cbr\u003e\u003c\/strong\u003eThe simultaneous dual-frequency 33kHz and 131kHz signal output of the Signal Generators is ideal for maximising the number of buried services that can be energised and then detected.\u003c\/p\u003e\n\u003cp\u003eThe SGV4 Signal Generator can apply the dual frequency signal without direct connection to buried services, using either a Signal Clamp or the simple induction method from ground level, providing a significant improvement in the detection of the smaller diameter or poorly earthed cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE SIGNAL APPLICATION TECHNIQUES\u003cbr\u003e\u003c\/strong\u003eThe SGV4 offers three alternative ways to apply a Signal Generator signal:\u003c\/p\u003e\n\u003cp\u003eDirect Connection allows specific pipes or cables to be individually traced, identified and their depths measured. The use of Signal Clamps, Signal Injectors and Direct Connection leads make this mode the most effective method for pinpointing pipes and cables.\u003c\/p\u003e\n\u003cp\u003eIf it is difficult or inconvenient to use Direct Connection, then the Wraparound technique can be utilised to successfully energise a street or car park lighting cable.\u003c\/p\u003e\n\u003cp\u003eInduction allows the Signal Generator to induce a detectable and traceable signal to previously unknown, undetected or inaccessible underground metal pipes or cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIGH POWER SIGNAL\u003cbr\u003e\u003c\/strong\u003eThe fully adjustable One Watt Power Output of the SGV4 means that deeper and less conducting pipes and cables can be effectively energised and then traced over ever longer distances.\u003c\/p\u003e\n\u003cp\u003eIt also features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFOUR position power level adjustment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eso the operator has total control of how much power is in use and when.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePULSED\/CONTINUOUS SIGNAL OUTPUT\u003cbr\u003e\u003c\/strong\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePulsed or Continuous signal output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows operators to switch to the Pulsed Mode at the push of a button in high interference situations and keep on tracing. The SGV4 has a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eclear audible signal output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto indicate when it is in operation.\u003c\/p\u003e\n\u003cp\u003eA useful in-built\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eaudio mute control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis also included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDATA LOGGING\u003cbr\u003e\u003c\/strong\u003eTo compliment and support in-built data logging on the Cable Avoidance Tools, the SGV4 Signal Generator also has full data logging capability. A years worth of data can be stored, in normal usage, on both the Locator and Signal Generator. This can be conveniently transferred at any time via a USB to a supervisors PC for analysis.\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCALIBRATION\u003cbr\u003e\u003c\/strong\u003eThe SGV4 Signal Generators do not require periodic recalibration. A fully Automatic Daily Self Test (ADST) tests and confirms that they are functioning at their optimum level each day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUTOMATIC DAILY SELF TEST (ADST)\u003cbr\u003e\u003c\/strong\u003eThe SGV4 Signal Generators perform a comprehensive Automatic Daily Self Test (ADST).\u003c\/p\u003e\n\u003cp\u003eAt the start of each day of use, a positive Automatic Daily Self Test result gives confirmation to the operator that the kit is working at the optimum level.\u003c\/p\u003e\n\u003cp\u003eThe result of this test is recorded and stored on memory within the products in-built data files and can be downloaded onto a PC at any time within the following 12 months*.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT VALIDATION CERTIFICATION\u003cbr\u003e\u003c\/strong\u003eThese test results can be used to produce a Product Validation Certificate using the C.Scope PC Toolkit. In addition, any results of the Self Test that have been carried out in the last twelve months* are available. The PC Toolkit can also be used to view and print a copy of the original factory Calibration Certificate.\u003c\/p\u003e\n\u003cp\u003eC.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHIGH RESOLUTION BACKLIT DIGITAL DISPLAY\u003cbr\u003e\u003c\/strong\u003eThe SGV4 has a large, clear and easy to read backlit LCD mounted behind a protective polycarbonate lens. The display indicates functions selected, power level, connection quality and battery condition. It also displays the Automatic Daily Self Test results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eROBUST AND DURABLE CONSTRUCTION\u003cbr\u003e\u003c\/strong\u003eThe SGV4s twin wall construction is robust and durable. It also provides IP65 standard protection against dust and water ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eACCESSORY TRAY\u003cbr\u003e\u003c\/strong\u003eThe SGV4 Signal Generator has a large detachable accessory tray as its base. It can house not only the standard accessories (Direct Connection Leads, Earth Stake, Connection Magnets, 10m Auxiliary Earth Lead) and the Instruction Manual but also many of the optional extras such as Signal Clamps, Sondes and Signal Injectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE YEAR WARRANTY\u003cbr\u003e\u003c\/strong\u003eThe SGV4 comes with a three year Warranty (conditions apply).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Watt 4-Level adjustable Power Output\u003c\/li\u003e\n\u003cli\u003eSimultaneous 33+131kHz Signal\u003c\/li\u003e\n\u003cli\u003ePulsed or Continuous Output Signal\u003c\/li\u003e\n\u003cli\u003eThree Signal Application Techniques:\u003cbr\u003e\u003cem\u003eDirect Connection \/ Wraparound \/ Induction\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eAutomatic Daily Self Test\u003c\/li\u003e\n\u003cli\u003eData Logging of all Signal Generator activity\u003c\/li\u003e\n\u003cli\u003eData Transfer by USB\u003c\/li\u003e\n\u003cli\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/li\u003e\n\u003cli\u003eNo periodic Calibration required\u003c\/li\u003e\n\u003cli\u003eProduct Validation Certificate available\u003c\/li\u003e\n\u003cli\u003eIn-build Accessory Tray\u003c\/li\u003e\n\u003cli\u003eNetwork Rail Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpec\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name\u003cbr\u003e\u003c\/strong\u003eSGV4 Signal Generator\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003cbr\u003e\u003c\/strong\u003e125-2-5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControls\u003cbr\u003e\u003c\/strong\u003eAll operation is by push button control as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn\/Off\u003c\/li\u003e\n\u003cli\u003ePower Level: 4 available power levels via Increase and Decrease Power buttons\u003c\/li\u003e\n\u003cli\u003ePulse\/Continuous Output: toggles between pulse or continuous output using one push button\u003c\/li\u003e\n\u003cli\u003eAudio Output: toggles between loud, muted and silent audio output using one push button\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Indications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAudio Feedback on button push\u003c\/li\u003e\n\u003cli\u003eAudio pitch drops with increasing load current in Connected Mode\u003c\/li\u003e\n\u003cli\u003eAudio pitch changes with power level in Induced Mode\u003c\/li\u003e\n\u003cli\u003eAudio output pulses to indicate Pulsed Mode\u003c\/li\u003e\n\u003cli\u003eLow battery indicated by interrupted Audio and output signal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Indication\u003cbr\u003e\u003c\/strong\u003eMulti-segment Liquid Crystal Display indicating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Frequency\u003c\/li\u003e\n\u003cli\u003ePulse Mode\u003c\/li\u003e\n\u003cli\u003eContinuous Mode\u003c\/li\u003e\n\u003cli\u003eBattery Condition\u003c\/li\u003e\n\u003cli\u003eOutput Level (bargraph)\u003c\/li\u003e\n\u003cli\u003eSpeaker Mute\u003c\/li\u003e\n\u003cli\u003eSelf Test Result\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Connector\u003cbr\u003e\u003c\/strong\u003eStandard USB Mini B connector. USB 2.0 Compatible\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelf Test\u003cbr\u003e\u003c\/strong\u003eAutomatic Daily Self Test and manual Self Test function\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInduced = 131,072Hz and 32,768Hz\u003c\/li\u003e\n\u003cli\u003eConnected = 131,072Hz and 32,768Hz\u003c\/li\u003e\n\u003cli\u003eCarrier Pulse Frequency: 7.5Hz (pulsed mode)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnected Mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnection Mode automatically selected when lead is plugged into socket\u003c\/li\u003e\n\u003cli\u003eMaximum Output Voltage (open circuit): 28V rms\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current (short circuit): 65mA rms\u003c\/li\u003e\n\u003cli\u003eMaximum Power: 1W into 400Ω load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCase moulded from high impact plastic\u003c\/li\u003e\n\u003cli\u003eDesigned to withstand 1m (3’3”) drop onto a hard surface\u003c\/li\u003e\n\u003cli\u003eIncorporates clip on accessory storage compartment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWeight (including batteries, Connection Leads and Earth Stake\u003cbr\u003e\u003c\/strong\u003e3.4kg (7 lb 7 oz)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (with Accessory Tray fitted)\u003cbr\u003e\u003c\/strong\u003e360mm x 180mm x 230mm (14.1” x 7” x 9”)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003cbr\u003e\u003c\/strong\u003eInternal 4 x ‘D’ (LR20) cells (either alkaline non-rechargeable or NiMH rechargeable)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Life\u003cbr\u003e\u003c\/strong\u003eup to 40 hours intermittent use at 20ºC (68ºF) using alkaline cells\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003cbr\u003e\u003c\/strong\u003e65\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Rail Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNotes\u003cbr\u003e\u003c\/strong\u003ePerformance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Signal Generators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014\/53\/EU (EMC). Compliance has been demonstrated by testing representative samples to the harmonised standards EN300-330 and EN301-489. The essential radio test suites have been carried out and the equipment is in conformity with all applicable directives. All C.Scope Signal Generators comply with the essential requirements and other provisions of Council Directive 2011\/65\/EU (RoHS).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSGV-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne Watt Power\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Levels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator \/ Transmitter Frequencies\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33+131kHz (Connected and Induced)\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 131kHz (Connected and Induced)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 33kHz (Connected and Induced)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 8kHz (Connected and Induced)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 512Hz (Connected)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – 640Hz (Connected)\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulsed \/ Continuous Output Signal\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Connection Modes\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – Direct Connection\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – Wraparound\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e – Induction\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Daily Self Test\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer via USB\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Resolution Backlit Liquid Crystal Display\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo Periodic Calibration*\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree Year Warranty**\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries*** 4 x D (LR20) Alkaline or NiMH Rechargeable\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-Built Accessory Tray****\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNo Periodic Calibration\u003c\/strong\u003e. The SGV4 does not require periodic recalibration. A Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.\u003c\/p\u003e\n\u003cp\u003e**\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Year warranty\u003c\/strong\u003e. Conditions apply.\u003c\/p\u003e\n\u003cp\u003e***\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBatteries\u003c\/strong\u003e. 4 x D LR20 Alkaline or NiMH Rechargeable batteries housed in a secure battery compartment.\u003c\/p\u003e\n\u003cp\u003e****\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIn-Built Accessory Tray\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes Direct Connection Lead, Auxiliary 10m Earth Lead, Connection Magnets, Earth Stake and Instruction Manual\u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/10\/18_3-CATXL4-MANUAL_1018v2.pdf\"\u003e\u003cem\u003e\u003cspan\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003eSGV4 Signal Generator Manual\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766008856960,"sku":"125-2-5","price":980.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/C.SCOPE-SGV4-1SIGNALTESTER-1.jpg?v=1741790599"},{"product_id":"c-scope-general-purpose-sonde-33khz","title":"C.SCOPE - GENERAL PURPOSE SONDE (33KHZ)","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan\u003eThe C.Scope 33kHz General Purpose Sonde is a transmitter used to trace the direction of pipes.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eA C.Scope 33kHz General Purpose Sonde is a small battery powered transmitter hermetically sealed in a robust torpedo shaped case which which can be screwed onto the end of a drain rod and fed into a pipe. The pipe direction can be then be traced using a \u003ca href=\"https:\/\/www.rigginguk.co.uk\/collections\/c-scope-cable-avoidance-equipment\" target=\"_blank\" title=\"link-to-c-scope-cable-avoidance-equipment\" rel=\"noopener\"\u003eC.Scope Locator\u003c\/a\u003e set to Generator\/ Transmitter Mode. The location of a pipe blockage can be identified using this system with enormous cost saving potential.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"color: #ff8000;\"\u003e** As standard the Sonde is supplied from the manufacture with drain rod adaptor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eOur Duct rod adaptor can be found\u003c\/strong\u003e \u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cabledrumjacks.co.uk\/collections\/c-scope-accessories\/products\/sonde-duct-rod-adaptor-for-9mm-11mm-or-14mm-rods\" style=\"color: #ff2a00;\"\u003eHERE\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOVERVIEW\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003eOrange case to identify the 33kHz version.\u003c\/li\u003e\n\u003cli\u003e33kHz transmit signal allowing detection and tracing.\u003c\/li\u003e\n\u003cli\u003eSimple to use.\u003c\/li\u003e\n\u003cli\u003eVery robust.\u003c\/li\u003e\n\u003cli\u003eSingle AA battery operation.\u003c\/li\u003e\n\u003cli\u003eFully weatherproof design to IP65.\u003c\/li\u003e\n\u003cli\u003eAdaptors available for different Drain Rod types.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSPEC\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003cbr\u003e\u003c\/strong\u003eGeneral Purpose Sonde 33kHz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003cbr\u003e\u003c\/strong\u003eSKU 125-7-1 \/\/ YIRS-33\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eWaterproof robust plastic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating frequency\u003cbr\u003e\u003c\/strong\u003e32768Hz continuous.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRange\u003cbr\u003e\u003c\/strong\u003e5 – 7 metres dependant on Locator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e38mm diameter\u003cbr\u003e102mm length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitting\u003cbr\u003e\u003c\/strong\u003eM10 stud\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery\u003cbr\u003e\u003c\/strong\u003e1 x AA (IEC type LR6) typically giving up to 50 hours intermittent use at 20C.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDOWNLOADS\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2019\/11\/19-CScope-Accessories-Manual.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cspan data-mce-fragment=\"1\"\u003eGeneral Purpose Sonde (33KHz) Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL3_4pp-1-1.pdf\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766008955264,"sku":"125-7-1","price":373.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/C.SCOPE_General_Purpose_Sonde_33KHZ.jpg?v=1741790606"},{"product_id":"c-scope-general-purpose-sonde-8khz","title":"C.SCOPE - GENERAL PURPOSE SONDE (8KHZ) - Green - To Trace the Direction of Pipes","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan\u003eThe C.Scope 8kHz General Purpose Sonde is a transmitter used to trace the direction of pipes.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eA C.Scope 8kHz General Purpose Sonde is a small battery powered transmitter hermetically sealed in a robust torpedo shaped case which which can be screwed onto the end of a drain rod and fed into a pipe. The pipe direction can be then be traced using a C.Scope Precision Pipe and \u003ca rel=\"noopener\" title=\"link-to-c-scope-cable-avoidance-equipment\" href=\"https:\/\/www.rigginguk.co.uk\/collections\/c-scope-cable-avoidance-equipment\" target=\"_blank\"\u003eCable Locator\u003c\/a\u003e. The location of a pipe blockage can be identified using this system with enormous cost saving potential.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"color: #ff8000;\"\u003e** As standard the Sonde is supplied from the manufacture with drain rod adaptor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eOur Duct rod adaptor can be found\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cabledrumjacks.co.uk\/collections\/c-scope-accessories\/products\/sonde-duct-rod-adaptor-for-9mm-11mm-or-14mm-rods\" style=\"color: #ff2a00;\"\u003eHERE\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOVERVIEW\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003eGreen case to identify the 8kHz version.\u003c\/li\u003e\n\u003cli\u003e8kHz transmit signal allowing detection and tracing by a C.Scope Precision Pipe and Cable Locator.\u003c\/li\u003e\n\u003cli\u003eSimple to use.\u003c\/li\u003e\n\u003cli\u003eVery robust.\u003c\/li\u003e\n\u003cli\u003eSingle AA battery operation.\u003c\/li\u003e\n\u003cli\u003eFully weatherproof design to IP65.\u003c\/li\u003e\n\u003cli\u003eAdaptors available for different Drain Rod types.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSPEC\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003cbr\u003e\u003c\/strong\u003eGeneral Purpose Sonde 8kHz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003cbr\u003e\u003c\/strong\u003eYIRS-8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eWaterproof robust plastic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating frequency\u003cbr\u003e\u003c\/strong\u003e8192Hz continuous.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRange\u003cbr\u003e\u003c\/strong\u003e5 – 7 metres dependant on Locator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e38mm diameter.\u003cbr\u003e102mm length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitting\u003cbr\u003e\u003c\/strong\u003eM10 stud\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery\u003cbr\u003e\u003c\/strong\u003e1 x AA (IEC type LR6) typically giving up to 50 hours intermittent use at 20C.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDOWNLOADS\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2019\/11\/19-CScope-Accessories-Manual.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cspan data-mce-fragment=\"1\"\u003eGeneral Purpose Sonde (8KHz) Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL3_4pp-1-1.pdf\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766009053568,"sku":"125-7-2","price":398.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/General_Purpose_Green_Sonde_8KHZ_used_to_trace_the_direction_of_pipes.jpg?v=1741790609"},{"product_id":"c-scope-metal-pipe-sonde","title":"C.SCOPE - METAL PIPE SONDE - RED","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan\u003eThe C.Scope Metal Pipe Sonde is a small, self-contained low frequency transmitter that can be used inside metallic pipes.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eTo address the problems of detecting the position of a blockage or other relevant feature within a metal pipe, the \u003cem\u003e\u003cspan style=\"text-decoration: underline;\"\u003eC.Scope Metal Pipe Sonde is specially designed with a low frequency signal output that is capable of being transmitted through the metal pipe walls to the surface.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThis makes it ideal for finding the position of blockages in metal pipes or for use with a camera and is powerful enough to be detectable at up to 5 metres depth with a C.Scope Precision Pipe and Cable Locator (dependant on pipe material and wall thickness).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"color: #ff8000;\"\u003e** As standard the Sonde is supplied from the manufacture with drain rod adaptor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eOur Duct rod adaptor can be found\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cabledrumjacks.co.uk\/collections\/c-scope-accessories\/products\/sonde-duct-rod-adaptor-for-9mm-11mm-or-14mm-rods\" style=\"color: #ff2a00;\"\u003eHERE\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOVERVIEW\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003eRed case to identify as the Low Frequency Sonde.\u003c\/li\u003e\n\u003cli\u003e512Hz or 640Hz transmit signal allowing detection and tracing by a C.Scope Precision Pipe and Cable Locator.\u003c\/li\u003e\n\u003cli\u003eSimple to use.\u003c\/li\u003e\n\u003cli\u003eVery robust.\u003c\/li\u003e\n\u003cli\u003eSingle AA battery operation.\u003c\/li\u003e\n\u003cli\u003eFully weatherproof design to IP68.\u003c\/li\u003e\n\u003cli\u003eCompatible with most drain rods.\u003c\/li\u003e\n\u003cli\u003eResin sealed electronics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSPEC\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003cbr\u003e\u003c\/strong\u003eMetal Pipe Sonde\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Numbers\u003cbr\u003e\u003c\/strong\u003eYIRS-512 and YIRS-640\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating frequency\u003cbr\u003e\u003c\/strong\u003eTransmits 512Hz and 640Hz respectively\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRange\u003cbr\u003e\u003c\/strong\u003eUp to 5 metres with a C.Scope Precision Pipe and Cable Locator (dependant on pipe material and wall thickness).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e39mm diameter.\u003cbr\u003e121mm length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnd fitting\u003cbr\u003e\u003c\/strong\u003eM10 threaded stud supplied with 7 t.p.i. rod fitting (other adaptors are available).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery\u003cbr\u003e\u003c\/strong\u003e1 x AA (IEC type LR6) typically giving up to 25 hours intermittent use at 20C.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDOWNLOADS\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2019\/11\/19-CScope-Accessories-Manual.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cspan data-mce-fragment=\"1\"\u003eMetal Pipe Sonde Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL3_4pp-1-1.pdf\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2019\/11\/19-CScope-Metal-Pipe-Sonde-Data-Sheet.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003eMetal Pipe Sonde Brochure\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"512Hz","offer_id":55766009119104,"sku":"125-7-3","price":423.6,"currency_code":"GBP","in_stock":true},{"title":"640Hz","offer_id":55766009151872,"sku":"125-7-4","price":423.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/C.Scope_Metal_Pipe_Sonde.jpg?v=1741790613"},{"product_id":"c-scope-duct-sonde-33khz","title":"C.SCOPE - DUCT SONDE (33KHZ) - Small Diameter for Congested Ducts","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan\u003eThe Duct Sonde 33KHz from C.SCOPE is a transmitter used to trace the direction of small and congested ducts or conduits.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe C.Scope 33KHz Duct Sonde is a small battery powered transmitter which can be screwed onto the end of a duct rod and inserted and fed into a a duct or conduit. The direction of the duct or conduit can then be traced by a \u003ca href=\"https:\/\/www.rigginguk.co.uk\/collections\/c-scope-cable-avoidance-equipment\" title=\"link-to-c-scope-cable-avoidance-equipment\"\u003eC.Scope locator\u003c\/a\u003e set to Generator\/ Transmitter Mode. The location of a blockage can be identified using this system with enormous cost saving potential.\u003c\/p\u003e\n\u003cp\u003eOften the standard sized Sonde is too large to pass between cables when tracing electrical, telecommunication or cable conduits or ducts. The solution is the C.Scope 33kHz Duct Sonde. The small diameter Duct Sonde, developed in conjunction with British Telecom, can be fed easily inside ducting without snagging.\u003c\/p\u003e\n\u003cp\u003eUse to trace smaller diameter non-metallic cable ducts and pipes.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOVERVIEW\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003e33kHz transmit signal allowing detection and tracing by a Cable Avoidance Tool.\u003c\/li\u003e\n\u003cli\u003eSimple to use.\u003c\/li\u003e\n\u003cli\u003eVery robust.\u003c\/li\u003e\n\u003cli\u003eSame diameter as Duct rod.\u003c\/li\u003e\n\u003cli\u003eSingle AAA battery operation.\u003c\/li\u003e\n\u003cli\u003eLow battery signal.\u003c\/li\u003e\n\u003cli\u003eFully weatherproof design to IP65\u003c\/li\u003e\n\u003cli\u003eCompatible with most rods.\u003c\/li\u003e\n\u003cli\u003eResin sealed electronics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSPEC\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003cbr\u003e\u003c\/strong\u003eDuct Sonde 33kHz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003cbr\u003e\u003c\/strong\u003eYIRSD-33\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eWaterproof, robust plastic, O Ring battery compartment seal, stainless steel end fittings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating frequency\u003cbr\u003e\u003c\/strong\u003e32,768Hz continuous.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRange\u003cbr\u003e\u003c\/strong\u003e3.5 – 4.5 metres dependant on Locator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e24mm diameter.\u003cbr\u003e200mm length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitting\u003cbr\u003e\u003c\/strong\u003eStandard rod thread (” Whitworth 16 T.P.I.), female connector at one end.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery\u003cbr\u003e\u003c\/strong\u003e1 x AAA (IEC type LR03) Alkaline typically giving up to 20 hours intermittent use at 20C.\u003cbr\u003eBattery low indicated by pulsed 32,768Hz signal.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDOWNLOADS\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2019\/11\/19-CScope-Accessories-Manual.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cspan data-mce-fragment=\"1\"\u003eGeneral Purpose Sonde (33KHz) Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL3_4pp-1-1.pdf\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766009217408,"sku":"125-7-8","price":513.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/General_Purpose_Small_Diameter_Yellow_Sonde_for_Congested_Ducts.jpg?v=1741790617"},{"product_id":"c-scope-plastic-pipe-tracer","title":"C.SCOPE - PLASTIC PIPE TRACER","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan\u003eThe Plastic Pipe Tracers allow SMALL diameter, non-metallic pipes to be traced.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe unique C.Scope Plastic Pipe Tracers are designed specifically to allow SMALL diameter, non-metallic pipes to be traced.\u003c\/p\u003e\n\u003cp\u003eC.Scope Plastic Pipe Tracers are the smallest diameter product on the market and can be successfully inserted into pipes when nothing else fits. Their unique construction gives unparalleled reliability and yet allows both line tracing AND the all important end tracing using the remarkable Sonde technology housed at the very tip of the Tracers.\u003c\/p\u003e\n\u003cp\u003eUtilities and utility contractors have, for years, used Sondes to follow non-metallic main service pipes underground and to record their route or locate the position of blockages within those pipes. However, with pipes less than 2”or 50mm in diameter, standard sized Sondes are simply too large to fit into the pipe or to negotiate the tighter bends often found on these pipes runs.\u003c\/p\u003e\n\u003cp\u003eDeveloped as a result of requests from the British gas industry, in need of a solution to the problem of tracing their small diameter non-metallic pipes, C.Scope designed the world’s smallest Sonde that is actually moulded into the tip of 6mm diameter plastic pipe tubing. Its uniform diameter allows easy use with any proprietary ‘live insertion’ gland and the flexibility of the plastic tubing and the Sonde itself make it ideally suited to successfully negotiating the tightest swept bends or even 90 degree elbows often encountered on the smaller pipes.\u003c\/p\u003e\n\u003cp\u003eStored on a compact reel, weighing less than 2kg, the C.Scope 20 metre and 50 metre Plastic Pipe Tracers are the ideal solution for small diameter non-metallic pipe tracing and can be used with any Pipe and Cable Locator and Signal Generator operating at 33kHz. Both the line of the pipe and the end point can be quickly and accurately identified at depths up to 4 metres.\u003c\/p\u003e\n\u003cp\u003eComes in 20 metre or 50 metre lengths.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOVERVIEW\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003eExtremely small diameter can be used in pipes down to 10mm.\u003c\/li\u003e\n\u003cli\u003eHighly robust, resistant to kinking.\u003c\/li\u003e\n\u003cli\u003eAvailable in 20metre and 50metre lengths.\u003c\/li\u003e\n\u003cli\u003eFull length or tip only detection capability.\u003c\/li\u003e\n\u003cli\u003eWater and gas proof.\u003c\/li\u003e\n\u003cli\u003eUniform diameter to allow easy use with any proprietary insertion gland.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSPEC\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003cbr\u003e20m and 50m Plastic Pipe Tracer\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Nos.\u003c\/strong\u003e\u003cbr\u003eYIRPPT20-33 and YIRPPT50-33\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003cbr\u003eOperates at 32,768Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetection Depth Range\u003c\/strong\u003e\u003cbr\u003eLine Detection: 3m (dependent upon Locator and Signal Generator type and site conditions)\u003cbr\u003eTip Detection: 4m (dependent upon Locator and Signal Generator type and site conditions)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003cbr\u003eAny Signal Generator or Transmitter with 33kHz or 33\/131kHz combined output\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRod Length\u003c\/strong\u003e\u003cbr\u003e20m or 50m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRod and Sonde Diameter\u003c\/strong\u003e\u003cbr\u003e6mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRod Minimum Bend Radius\u003c\/strong\u003e\u003cbr\u003e50mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003cbr\u003eReel: Robust plastic housing\u003cbr\u003eRod: Flexible, chemical resistant plastic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReel dimensions (20m)\u003c\/strong\u003e\u003cbr\u003e150 x 120 x 250mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReel dimensions (50m)\u003c\/strong\u003e\u003cbr\u003e165 x 290 x 240mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReel weight (20m)\u003c\/strong\u003e\u003cbr\u003e1248 g\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReel weight (50m)\u003c\/strong\u003e\u003cbr\u003e2073 g\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Temperature Range\u003c\/strong\u003e\u003cbr\u003e-20ºC to 50ºC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003cbr\u003e-20ºC to 50ºC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP rating for actual Tracer Rod \u0026amp; Tip\u003c\/strong\u003e\u003cbr\u003e68\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP rating for Plastic Pipe Tracer Casing\u003c\/strong\u003e\u003cbr\u003e54\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDOWNLOADS\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2019\/11\/19-CScope-Accessories-Manual.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cspan data-mce-fragment=\"1\"\u003ePlastic Pipe Tracer Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL3_4pp-1-1.pdf\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2019\/11\/19-CScope-Plastic-Pipe-Tracer-Data-Sheet.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-fragment=\"1\"\u003ePlastic Pipe Tracer Brochure\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"20m","offer_id":55766009250176,"sku":"125-7-9","price":402.0,"currency_code":"GBP","in_stock":true},{"title":"50m","offer_id":55766009282944,"sku":"125-7-10","price":552.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/Screenshot_2_ee564228-7783-4920-957e-e0efd481539b.png?v=1741790622"},{"product_id":"c-scope-80m-flexible-tracer-33khz","title":"C.SCOPE - 80M FLEXIBLE TRACER 33kHz (Fibreglass Rod in Frame)","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan\u003eThe C.SCOPE Flexible Tracer is highly effective at locating and tracing the route of small diameter, non-metallic ducts, pipes, sewers and drains.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eWhen used with any \u003ca href=\"https:\/\/www.rigginguk.co.uk\/collections\/c-scope-cable-avoidance-equipment\" target=\"_blank\" title=\"link-to-c-scope-cable-avoidance-equipment\" rel=\"noopener\"\u003eC.Scope Cable Locator \u003c\/a\u003eand Signal Generator, both the route of a non-metallic pipe and a particular end point can be pinpointed with the Flexible Tracer. This is particularly useful for identifying the position of any blockages or obstructions within the pipe. If a depth measuring Locator is being used then it is also possible to know the depth of the pipe\/blockage.\u003c\/p\u003e\n\u003cp\u003eThe Flexible Tracer is lightweight and compact making it very easy to transport. It comprises a 6mm diameter, 80m long continuous fibreglass rod housed in a strong reel that rotates on an axle. The axle has a slip-ring allowing the Signal Generator to remain connected to the Connection Terminals of the Flexible Tracer whilst it is being inserted into the pipe to be traced. A tiny Sonde is built into the tip of the Flexible Tracer allowing the end point of the Tracer to also be located. Uniquely, this Sonde is also flexible allowing the Flexible Tracer to negotiate bends in a pipe that would ordinarily stop a conventional Sonde from getting past.\u003c\/p\u003e\n\u003cp\u003eThere are two main methods for tracing the route of non-metallic pipes using the Flexible Tracer:\u003c\/p\u003e\n\u003cp\u003eLine Location – Feed the rod into the pipe\/duct and attach one Direct Connection lead of a Signal Generator to one connection terminal of the Tracer and the other Direct Connection lead to an Earth Stake. The Rod can then be located thus identifying the route of the pipe.\u003c\/p\u003e\n\u003cp\u003eTip\/Sonde Location – Feed the rod into the pipe\/duct and attach one Direct Connection lead of a Signal Generator to one connection terminal of the Tracer and the other Direct Connection lead to the other terminal. This energizes the Sonde at the tip of the Flexible Tracer allowing the end point and the depth of the Flexible Tracer to be identified.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOVERVIEW\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli\u003eFibreglass rod inside a drum cage mounted in a tubular steel frame.\u003c\/li\u003e\n\u003cli\u003e80m of 5mm diameter flexible fibreglass rod with fully integrated 9.5mm diameter Sonde.\u003c\/li\u003e\n\u003cli\u003eIntegral Sonde for tip tracing.\u003c\/li\u003e\n\u003cli\u003eIntegral wire for line tracing.\u003c\/li\u003e\n\u003cli\u003eSlip Ring allowing drum rotation when in use.\u003c\/li\u003e\n\u003cli\u003eRotation brake.\u003c\/li\u003e\n\u003cli\u003eUnique flexible Sonde performs even in tight angles.\u003c\/li\u003e\n\u003cli\u003eRobust but lightweight construction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eSPEC\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003cbr\u003e80 m Flexible Tracer\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003cbr\u003eSKU 125-7-11 \/\/ YIRRFT-80\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003cbr\u003eOptimised for 32,768Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetection Depth Range:\u003c\/strong\u003e\u003cbr\u003eLine Detection 3 m (dependent upon Locator and Signal Generator type and site conditions)\u003cbr\u003eTip Detection 4 m (dependent upon Locator and Signal Generator type and site conditions)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003cbr\u003eAny Signal Generator or Transmitter with 33kHz or 33\/131kHz combined output\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRod Length\u003c\/strong\u003e\u003cbr\u003e80 m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRod Diameter\u003c\/strong\u003e\u003cbr\u003e5 mm nominal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRod Material\u003c\/strong\u003e\u003cbr\u003eQuality sleeved fibreglass rod with three integral copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRod Minimum Bend Radius\u003c\/strong\u003e\u003cbr\u003e10 cm (reducing to 15 cm, 5 cm from Tip)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRod wire diameter\u003c\/strong\u003e\u003cbr\u003e0.45 mm each wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTip Length\u003c\/strong\u003e\u003cbr\u003e160 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTip Diameter\u003c\/strong\u003e\u003cbr\u003e9.5 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTip Material\u003c\/strong\u003e\u003cbr\u003eBrass\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003cbr\u003e58.8 x 28.8 x 48.5 cm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrame Material\u003c\/strong\u003e\u003cbr\u003ePowder coated 16 mm steel tube\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReel Diameter\u003c\/strong\u003e\u003cbr\u003e48 cm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cbr\u003e7.5 kg\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSlip ring assembly\u003c\/strong\u003e\u003cbr\u003eSealed multi-wire duplexed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Temperature Range\u003c\/strong\u003e\u003cbr\u003e-20ºC to 50ºC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003cbr\u003e-20ºC to 50ºC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP rating\u003c\/strong\u003e\u003cbr\u003efor Tracer Rod \u0026amp; Tip 68\u003cbr\u003efor Casing 54\u003cbr\u003efor Terminal Box 66\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDOWNLOADS\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2019\/11\/19-CScope-Accessories-Manual.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/em\u003e \u003cspan data-mce-fragment=\"1\"\u003eFlexible Tracer Manual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2017\/03\/CSCOPE_CDXL3_4pp-1-1.pdf\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2019\/11\/19-CScope-Plastic-Pipe-Tracer-Data-Sheet.pdf\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" data-mce-fragment=\"1\"\u003eFlexible Tracer Brochure\u003c\/span\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766009479552,"sku":"125-7-11","price":957.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/C.SCOPE_-_Flexible_Tracer.jpg?v=1741790628"},{"product_id":"li-ion-rechargeable-locator-battery-pack","title":"C.SCOPE - Li-Ion Rechargeable Locator Battery Pack","description":"\u003ch4 class=\"about-text\" id=\"subtext\"\u003e\u003cstrong\u003e\u003cspan class=\"rvts6\"\u003eYou can use your battery pack right away. To maximise the life of your battery pack you should charge it fully before you use it. Connect either the supplied vehicle or wall charger and follow the instructions in \u003c\/span\u003eVehicle Charging\u003cspan class=\"rvts6\"\u003e or \u003c\/span\u003eMains Charging\u003cspan class=\"rvts6\"\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan class=\"rvts6\"\u003eThe battery pack fits in the battery compartment of your Locator, CS880, Transmitter or Signal Generator, in place of your alkaline batteries. Remove any existing batteries and insert the battery pack. For full instructions see \u003c\/span\u003eFitting in a Locator\u003cspan class=\"rvts6\"\u003e, \u003c\/span\u003eFitting in a Transmitter or Signal Generator\u003cspan class=\"rvts6\"\u003e, or \u003c\/span\u003eFitting in a CS880\u003cspan class=\"rvts6\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"rvps4\"\u003e\u003cstrong\u003e\u003cspan class=\"rvts0\"\u003e\u003cspan class=\"rvts21\"\u003eHANDLING\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"rvps2\"\u003e\u003cspan class=\"rvts20\"\u003eAvoid disassembling, crushing, or puncturing the battery. Do not short the external contacts, expose it to temperatures above 60°C, or subject it to excessive shock or vibration. Keep it away from children and do not use a damaged battery. If a battery pack leaks, do not touch the fluids and dispose of it, as described below.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"rvps4\"\u003e\u003cstrong\u003e\u003cspan class=\"rvts0\"\u003e\u003cspan class=\"rvts21\"\u003eSTORAGE\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"rvps2\"\u003e\u003cspan class=\"rvts20\"\u003eTo prevent fires, store the battery packs in the supplied packaging when not in use. You should consider using a lithium-ion battery storage cabinet, which may offer fire protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"rvps4\"\u003e\u003cstrong\u003e\u003cspan class=\"rvts0\"\u003e\u003cspan class=\"rvts21\"\u003eTRANSPORT\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"rvps2\"\u003e\u003cspan class=\"rvts6\"\u003eC.Scope Battery Packs are subject to legislation on the transport of dangerous goods. When a \u003c\/span\u003e\u003cspan class=\"rvts20\"\u003ebattery pack\u003c\/span\u003e\u003cspan class=\"rvts6\"\u003e is transported, special requirements on packaging and labelling apply. Do not ship damaged \u003c\/span\u003e\u003cspan class=\"rvts20\"\u003ebattery packs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"rvps4\"\u003e\u003cstrong\u003e\u003cspan class=\"rvts0\"\u003e\u003cspan class=\"rvts21\"\u003eDISPOSAL\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"rvps2\"\u003e\u003cspan class=\"rvts6\"\u003eC.Scope Battery Packs should be recycled at permitted facilities and not thrown away in household trash or recycling bins. They contain chemicals that can catch fire and explode, and high-capacity batteries can also deliver an electric shock. You can take lithium-ion batteries to a local recycling centre or hazardous waste collection point. You can check with your local authority or vendor to see if they offer recycling services.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDOWNLOADS\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2024\/11\/BatteryPack-Brochurev1.2-PENDING.pdf\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003e\u003c\/a\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2024\/11\/BatteryPack-Brochurev1.2-PENDING.pdf\" style=\"color: rgb(255, 0, 0);\"\u003eXL Locator Li-Ion Rechargeable Battery Pack Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2024\/11\/BatteryPack-Brochurev1.2-PENDING.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003e\u003c\/a\u003e\u003cspan style=\"color: rgb(255, 3, 3);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2024\/11\/BatteryPack-Brochurev1.2-PENDING.pdf\" style=\"color: rgb(255, 3, 3);\"\u003eXL Locator Li-Ion Rechargeable Battery Pack Brochure\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766009676160,"sku":"125-5-1","price":144.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/YLBP-XL-1-RX-SIDE.png?v=1741790645"},{"product_id":"c-scope-signal-clamp","title":"C-SCOPE - Signal Clamp","description":"\u003cdiv class=\"product-header-intro\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"columns small-12\"\u003e\n\u003cp\u003e\u003cstrong\u003eA Signal Clamp is a safe and straightforward way to apply the Generator\/Transmitter signal to a cable or small pipe to enable precision tracing of this service.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe C.Scope Signal Clamp allows operators to apply the Signal Generator\/ Transmitter signal effectively to any cable. It is an extremely practical way to allow individual cables to be traced even when the cable is in amongst other cables.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSPEC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003cbr\u003e\u003c\/strong\u003eSignal Clamp\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003cbr\u003e\u003c\/strong\u003eSKU 125-6-1 \/\/ YIRC-33-8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eToroidal induction ring housed in robust plastic.\u003cbr\u003eSpring loaded jaws.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptimisation\u003cbr\u003e\u003c\/strong\u003eTuned for optimum use with 33kHz Signal Generators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety\u003cbr\u003e\u003c\/strong\u003eBuilt to conform to BSEN61010-1:1993 and BSEN 61010-2-032:1995\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003e270 x 160 x 28mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility\u003cbr\u003e\u003c\/strong\u003eMaximum service diameter = 105mm\u003cbr\u003eSuitable for use with all C.Scope Signal Generators and Transmitters.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDOWNLOADS\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2021\/12\/Accessories_Manual-4.pdf\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003cstrong\u003eSignal Clamp Manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766009840000,"sku":"125-6-1","price":333.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/Signal-Clamp-hi-res-scaled-1.webp?v=1741790648"},{"product_id":"c-scope-signal-injector-uk-version","title":"C.SCOPE - Signal Injector (UK Version)","description":"\u003cdiv class=\"product-header-intro\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"columns small-12\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe Signal Injector is an accessory that allows the Signal Generator signal to be safely applied to an electrical system via a conventional 3-pin power socket.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe C.Scope Signal Injector is an accessory which when connected to a C.Scope Signal Generator or Transmitter applies a signal safely to an electrical system via a conventional 3-pin power socket. This signal will then be detectable on the buried supply cable outside the building and any supply cables within the property.\u003c\/p\u003e\n\u003cp\u003eTo transmitted signal can then be detected by a C.Scope Cable Avoidance Tool or Precision Pipe and Cable Locator.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOVERVIEW\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHighly efficient transfer of Signal Generator signal to electricity supply cable.\u003c\/li\u003e\n\u003cli\u003eIsolates Signal Generator from electrical supply for safety.\u003c\/li\u003e\n\u003cli\u003eUK or Schuko plug types.\u003c\/li\u003e\n\u003cli\u003eFully weatherproof design to IP65.\u003c\/li\u003e\n\u003cli\u003eCan be used with all C.Scope Locators, Generators and Transmitters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSPEC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003cbr\u003e\u003c\/strong\u003eSignal Injector\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003cbr\u003e\u003c\/strong\u003eYIRIP-33-8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003eBox: 100mm x 50mm x 25mm\u003cbr\u003eInput Lead: 1m\u003cbr\u003eOutput Lead: 1.5m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eEncapsulated, robust housing\u003cbr\u003eMoisture \/ dust resistant to IP54\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Output (Mains side)\u003cbr\u003e\u003c\/strong\u003eElectrical Isolation: Class II (Double Insulated)\u003cbr\u003eMains Plug Connector: UK, 3 pin to BS1363, load between Live and Earth or 2 pin European Shuko style\u003cbr\u003eMaximum Voltage: 250 V rms\u003cbr\u003eMaximum Load: \u0026lt;10mA (predominantly capacitive)\u003cbr\u003eFrequency range: 45-65 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Input (Signal Generator side)\u003cbr\u003e\u003c\/strong\u003eConnector: 3 pin XLR male (industry standard)\u003cbr\u003eMaximum Voltage: 42 V rms\u003cbr\u003eMaximum Power: \u0026lt;250mW when driven from SGA or SGV\u003cbr\u003eInput Impedance: 2000 Ohms\u003cbr\u003eFrequency: 33 kHz\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDOWNLOADS\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2021\/12\/Accessories_Manual-4.pdf\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003cstrong\u003eSignal Injector Manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2019\/11\/19-CScope-Signal-Injector-Data-Sheet.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003cstrong\u003eSignal Injector Brochure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766010200448,"sku":null,"price":206.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/cscope_signal_injector.webp?v=1741790655"},{"product_id":"c-scope-signal-injector-eu-version","title":"C-SCOPE - Signal Injector (EU Version)","description":"\u003cdiv class=\"product-header-intro\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"columns small-12\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe Signal Injector is an accessory that allows the Signal Generator signal to be safely applied to an electrical system via a conventional 3-pin power socket.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe C.Scope Signal Injector is an accessory which when connected to a C.Scope Signal Generator or Transmitter applies a signal safely to an electrical system via a conventional 3-pin power socket. This signal will then be detectable on the buried supply cable outside the building and any supply cables within the property.\u003c\/p\u003e\n\u003cp\u003eTo transmitted signal can then be detected by a C.Scope Cable Avoidance Tool or Precision Pipe and Cable Locator.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOVERVIEW\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHighly efficient transfer of Signal Generator signal to electricity supply cable.\u003c\/li\u003e\n\u003cli\u003eIsolates Signal Generator from electrical supply for safety.\u003c\/li\u003e\n\u003cli\u003eUK or Schuko plug types.\u003c\/li\u003e\n\u003cli\u003eFully weatherproof design to IP65.\u003c\/li\u003e\n\u003cli\u003eCan be used with all C.Scope Locators, Generators and Transmitters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSPEC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003cbr\u003e\u003c\/strong\u003eSignal Injector\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003cbr\u003e\u003c\/strong\u003eYIRIP-33-8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003cbr\u003e\u003c\/strong\u003eBox: 100mm x 50mm x 25mm\u003cbr\u003eInput Lead: 1m\u003cbr\u003eOutput Lead: 1.5m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003cbr\u003e\u003c\/strong\u003eEncapsulated, robust housing\u003cbr\u003eMoisture \/ dust resistant to IP54\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Output (Mains side)\u003cbr\u003e\u003c\/strong\u003eElectrical Isolation: Class II (Double Insulated)\u003cbr\u003eMains Plug Connector: UK, 3 pin to BS1363, load between Live and Earth or 2 pin European Shuko style\u003cbr\u003eMaximum Voltage: 250 V rms\u003cbr\u003eMaximum Load: \u0026lt;10mA (predominantly capacitive)\u003cbr\u003eFrequency range: 45-65 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Input (Signal Generator side)\u003cbr\u003e\u003c\/strong\u003eConnector: 3 pin XLR male (industry standard)\u003cbr\u003eMaximum Voltage: 42 V rms\u003cbr\u003eMaximum Power: \u0026lt;250mW when driven from SGA or SGV\u003cbr\u003eInput Impedance: 2000 Ohms\u003cbr\u003eFrequency: 33 kHz\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDOWNLOADS\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2021\/12\/Accessories_Manual-4.pdf\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003cstrong\u003eSignal Injector Manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2019\/11\/19-CScope-Signal-Injector-Data-Sheet.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003cstrong\u003eSignal Injector Brochure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766010233216,"sku":"125-6-3","price":206.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/cscope_signal_injector_030578cf-883e-496e-b2f9-788414caa64b.webp?v=1741790658"},{"product_id":"c-scope-professional-carry-bag","title":"C.SCOPE - Professional Carry Bag","description":"\u003ch4\u003e\u003cstrong\u003eC.SCOPE produce a range of carry bags to transport and store Pipe and Cable Locator equipment and accessories.\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eA C.Scope Carry Bag will keep your C.Scope Pipe \u0026amp; Cable Locator Equipment \u0026amp; Accessories safe when not in use and will still have capacity to carry the additional locating accessories such as site maps, marker paint or pegs to site each time. Choose between the Professional Carry Bag that has specific compartments for each item or the Budget Carry Bag that is a loose holdall type of construction.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSPEC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003cbr\u003eProfessional Carry Bag\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003cbr\u003eSKU 125-6-4 YCB\/CS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cbr\u003e22 x 23 x 76cm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003cbr\u003e38 Litres\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDOWNLOADS\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/07\/16-CSCOPE-Carry-Bags-data-sheet-10-1.pdf\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003cstrong\u003eC.Scope CS880 Carry Bag Brochure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766011150720,"sku":"125-6-4","price":84.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/c-scope-ycbcs-professional-carry-bag_tyoedudyfxzwkuvi.jpg?v=1741790662"},{"product_id":"c-scope-large-carry-bag","title":"C.SCOPE - Large Carry Bag","description":"\u003ch4\u003e\u003cstrong\u003eC.SCOPE produce a range of carry bags to transport and store Pipe and Cable Locator equipment and accessories.\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eA C.Scope Carry Bag will keep your C.Scope Pipe \u0026amp; Cable Locator Equipment \u0026amp; Accessories safe when not in use and will still have capacity to carry the additional locating accessories such as \u003cstrong\u003esite\u003c\/strong\u003e maps, marker paint or pegs to site each time. Choose between the Professional Carry Bag that has specific compartments for each item or the Budget Carry Bag that is a loose holdall type of construction.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSPEC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003cbr\u003eLarge Carry Bag\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003cbr\u003eSKU 125-6-4 \/\/ YCBL\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cbr\u003e33 x 25 x 89cm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003cbr\u003e72 Litres\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDOWNLOADS\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2016\/07\/16-CSCOPE-Carry-Bags-data-sheet-10-1.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003cstrong\u003eC.Scope Large Carry Bag Brochure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766011412864,"sku":"125-6-5","price":60.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/Crop-Large-Carry-Bag-768x432.jpg?v=1741790666"},{"product_id":"li-ion-rechargeable-signal-generator-transmitter-battery-pack","title":"C.SCOPE - Li-Ion Rechargeable Signal Generator\/Transmitter Battery Pack","description":"\u003ch4 class=\"about-text\" id=\"subtext\"\u003e\u003cstrong\u003e\u003cspan class=\"rvts6\"\u003eYou can use your battery pack right away. To maximise the life of your battery pack you should charge it fully before you use it. Connect either the supplied vehicle or wall charger and follow the instructions in \u003c\/span\u003eVehicle Charging\u003cspan class=\"rvts6\"\u003e or \u003c\/span\u003eMains Charging\u003cspan class=\"rvts6\"\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan class=\"rvts6\"\u003eThe battery pack fits in the battery compartment of your Locator, CS880, Transmitter or Signal Generator, in place of your alkaline batteries. Remove any existing batteries and insert the battery pack. For full instructions see \u003c\/span\u003eFitting in a Locator\u003cspan class=\"rvts6\"\u003e, \u003c\/span\u003eFitting in a Transmitter or Signal Generator\u003cspan class=\"rvts6\"\u003e, or \u003c\/span\u003eFitting in a CS880\u003cspan class=\"rvts6\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"rvps4\"\u003e\u003cspan class=\"rvts0\"\u003e\u003cspan class=\"rvts21\"\u003eHANDLING\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"rvps2\"\u003e\u003cspan class=\"rvts20\"\u003eAvoid disassembling, crushing, or puncturing the battery. Do not short the external contacts, expose it to temperatures above 60°C, or subject it to excessive shock or vibration. Keep it away from children and do not use a damaged battery. If a battery pack leaks, do not touch the fluids and dispose of it, as described below.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"rvts0\"\u003e\u003cspan class=\"rvts21\"\u003eSTORAGE\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"rvps2\"\u003e\u003cspan class=\"rvts20\"\u003eTo prevent fires, store the battery packs in the supplied packaging when not in use. You should consider using a lithium-ion battery storage cabinet, which may offer fire protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"rvps4\"\u003e\u003cspan class=\"rvts0\"\u003e\u003cspan class=\"rvts21\"\u003eTRANSPORT\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"rvps2\"\u003e\u003cspan class=\"rvts6\"\u003eC.Scope Battery Packs are subject to legislation on the transport of dangerous goods. When a \u003c\/span\u003e\u003cspan class=\"rvts20\"\u003ebattery pack\u003c\/span\u003e\u003cspan class=\"rvts6\"\u003e is transported, special requirements on packaging and labelling apply. Do not ship damaged \u003c\/span\u003e\u003cspan class=\"rvts20\"\u003ebattery packs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"rvps4\"\u003e\u003cspan class=\"rvts0\"\u003e\u003cspan class=\"rvts21\"\u003eDISPOSAL\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"rvps2\"\u003e\u003cspan class=\"rvts6\"\u003eC.Scope Battery Packs should be recycled at permitted facilities and not thrown away in household trash or recycling bins. They contain chemicals that can catch fire and explode, and high-capacity batteries can also deliver an electric shock. You can take lithium-ion batteries to a local recycling centre or hazardous waste collection point. You can check with your local authority or vendor to see if they offer recycling services.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDOWNLOADS\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2024\/11\/BatteryPacksUserManualv1.4-PENDING.pdf\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2024\/11\/BatteryPacksUserManualv1.4-PENDING.pdf\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003eSGA\/MXT Li-ion Rechargeable Battery Pack Manual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2024\/11\/BatteryPack-Brochurev1.2-PENDING.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003eSGA\/MXT Li-ion Rechargeable Battery Pack Brochure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cspan style=\"color: rgb(255, 3, 3);\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766011445632,"sku":"125-5-5","price":144.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/YLBP-TX-1-SIDE.png?v=1741790671"},{"product_id":"li-ion-rechargeable-signal-generator-transmitter-battery-pack-copy","title":"C.SCOPE - Li-Ion Rechargeable Locator Battery Pack Kit","description":"\u003ch4 class=\"about-text\" id=\"subtext\"\u003e\u003cstrong\u003e\u003cspan class=\"rvts6\"\u003eYou can use your battery pack right away. To maximise the life of your battery pack you should charge it fully before you use it. Connect either the supplied vehicle or wall charger and follow the instructions in \u003c\/span\u003eVehicle Charging\u003cspan class=\"rvts6\"\u003e or \u003c\/span\u003eMains Charging\u003cspan class=\"rvts6\"\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan class=\"rvts6\"\u003eThe battery pack fits in the battery compartment of your Locator, CS880, Transmitter or Signal Generator, in place of your alkaline batteries. Remove any existing batteries and insert the battery pack. For full instructions see \u003c\/span\u003eFitting in a Locator\u003cspan class=\"rvts6\"\u003e, \u003c\/span\u003eFitting in a Transmitter or Signal Generator\u003cspan class=\"rvts6\"\u003e, or \u003c\/span\u003eFitting in a CS880\u003cspan class=\"rvts6\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"rvps4\"\u003e\u003cspan class=\"rvts0\"\u003e\u003cspan class=\"rvts21\"\u003eHANDLING\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"rvps2\"\u003e\u003cspan class=\"rvts20\"\u003eAvoid disassembling, crushing, or puncturing the battery. Do not short the external contacts, expose it to temperatures above 60°C, or subject it to excessive shock or vibration. Keep it away from children and do not use a damaged battery. If a battery pack leaks, do not touch the fluids and dispose of it, as described below.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"rvps4\"\u003e\u003cspan class=\"rvts0\"\u003e\u003cspan class=\"rvts21\"\u003eSTORAGE\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"rvps2\"\u003e\u003cspan class=\"rvts20\"\u003eTo prevent fires, store the battery packs in the supplied packaging when not in use. You should consider using a lithium-ion battery storage cabinet, which may offer fire protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"rvps4\"\u003e\u003cspan class=\"rvts0\"\u003e\u003cspan class=\"rvts21\"\u003eTRANSPORT\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"rvps2\"\u003e\u003cspan class=\"rvts6\"\u003eC.Scope Battery Packs are subject to legislation on the transport of dangerous goods. When a \u003c\/span\u003e\u003cspan class=\"rvts20\"\u003ebattery pack\u003c\/span\u003e\u003cspan class=\"rvts6\"\u003e is transported, special requirements on packaging and labelling apply. Do not ship damaged \u003c\/span\u003e\u003cspan class=\"rvts20\"\u003ebattery packs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"rvps4\"\u003e\u003cspan class=\"rvts0\"\u003e\u003cspan class=\"rvts21\"\u003eDISPOSAL\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"rvps2\"\u003e\u003cspan class=\"rvts6\"\u003eC.Scope Battery Packs should be recycled at permitted facilities and not thrown away in household trash or recycling bins. They contain chemicals that can catch fire and explode, and high-capacity batteries can also deliver an electric shock. You can take lithium-ion batteries to a local recycling centre or hazardous waste collection point. You can check with your local authority or vendor to see if they offer recycling services.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDOWNLOADS\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2024\/11\/BatteryPacksUserManualv1.4-PENDING.pdf\"\u003e\u003cimg alt=\"Duct rod data sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003eCS880 Li-Ion Rechargeable Battery Pack Manual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cscopelocators.com\/wp-content\/uploads\/2024\/11\/BatteryPack-Brochurev1.2-PENDING.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/PDF_Download_thumb.png?v=1550738679\" alt=\"Duct rod data sheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 0, 0);\"\u003eCS880 Li-Ion Rechargeable Battery Pack Brochure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cspan style=\"color: rgb(255, 3, 3);\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"C.SCOPE","offers":[{"title":"Default Title","offer_id":55766011478400,"sku":"125-5-4","price":324.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1363\/1295\/files\/YLBP-TX-1-SIDE_de438b1e-df24-4b4e-9792-17dcaa923ce1.png?v=1741790675"}],"url":"https:\/\/cabledrumjacks.co.uk\/collections\/c-scope.oembed?page=2","provider":"Cabledrumjacks","version":"1.0","type":"link"}